手术后加载和固定植入物对胫骨骨折愈合过程的影响。

IF 2.2 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Shima Doorandish Yazdi, Dorna Hedayat, Amir Asadi, Ali Abouei Mehrizi
{"title":"手术后加载和固定植入物对胫骨骨折愈合过程的影响。","authors":"Shima Doorandish Yazdi, Dorna Hedayat, Amir Asadi, Ali Abouei Mehrizi","doi":"10.1002/cnm.3870","DOIUrl":null,"url":null,"abstract":"<p><p>Healing of tibia demonstrates a complex mechanobiological process as it is stimulated by the major factor of strains applied by body weight. The effect of screw heads and bodies as well as their pressure distribution is often overlooked. Hence, effective mechanical conditions of the healing process of tibia can be categorized into the material of the plate and screws, post-operation loadings, and screw type and pressure. In this paper, a mathematical biodegradation model was used to simulate the PGF/PLA plate-screw device over 8 weeks. The effect of different post-operation loading patterns was studied for both locking and non-locking screws. The aim was to reach the best configuration for the most achievable healing using FEA by computing the healing pattern, trend, and efficiency with the mechano-regulation theory based on deviatoric strain. The biodegradation process of the plate and screws resulted in 82% molecular weight loss and 1.05 GPa decrease in Young's modulus during 8 weeks. The healing efficiency of the cases ranged from 4.72% to 14.75% in the first week and 18.64% to 63.05% in the eighth week. Finally, an optimal case was achieved by considering the prevention of muscle erosion, bone density reduction, and nonunion, according to the obtained results.</p>","PeriodicalId":50349,"journal":{"name":"International Journal for Numerical Methods in Biomedical Engineering","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impacts of post-operation loading and fixation implant on the healing process of fractured tibia.\",\"authors\":\"Shima Doorandish Yazdi, Dorna Hedayat, Amir Asadi, Ali Abouei Mehrizi\",\"doi\":\"10.1002/cnm.3870\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Healing of tibia demonstrates a complex mechanobiological process as it is stimulated by the major factor of strains applied by body weight. The effect of screw heads and bodies as well as their pressure distribution is often overlooked. Hence, effective mechanical conditions of the healing process of tibia can be categorized into the material of the plate and screws, post-operation loadings, and screw type and pressure. In this paper, a mathematical biodegradation model was used to simulate the PGF/PLA plate-screw device over 8 weeks. The effect of different post-operation loading patterns was studied for both locking and non-locking screws. The aim was to reach the best configuration for the most achievable healing using FEA by computing the healing pattern, trend, and efficiency with the mechano-regulation theory based on deviatoric strain. The biodegradation process of the plate and screws resulted in 82% molecular weight loss and 1.05 GPa decrease in Young's modulus during 8 weeks. The healing efficiency of the cases ranged from 4.72% to 14.75% in the first week and 18.64% to 63.05% in the eighth week. Finally, an optimal case was achieved by considering the prevention of muscle erosion, bone density reduction, and nonunion, according to the obtained results.</p>\",\"PeriodicalId\":50349,\"journal\":{\"name\":\"International Journal for Numerical Methods in Biomedical Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal for Numerical Methods in Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1002/cnm.3870\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal for Numerical Methods in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/cnm.3870","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

胫骨的愈合是一个复杂的机械生物学过程,因为它受到体重所产生的应变这一主要因素的刺激。螺钉头和螺钉体及其压力分布的影响往往被忽视。因此,胫骨愈合过程的有效机械条件可分为钢板和螺钉的材料、手术后的负荷以及螺钉的类型和压力。本文使用数学生物降解模型模拟了 PGF/PLA 钢板-螺钉装置在 8 周内的情况。研究了锁定螺钉和非锁定螺钉不同操作后加载模式的影响。其目的是利用有限元分析,通过基于偏离应变的机械调节理论计算愈合模式、趋势和效率,以达到最佳愈合配置。在 8 周的时间里,钢板和螺钉的生物降解过程导致了 82% 的分子量损失和 1.05 GPa 的杨氏模量下降。病例的愈合效率在第一周为 4.72% 至 14.75%,第八周为 18.64% 至 63.05%。最后,根据所获得的结果,考虑到防止肌肉侵蚀、骨密度降低和不愈合,达到了最佳病例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impacts of post-operation loading and fixation implant on the healing process of fractured tibia.

Healing of tibia demonstrates a complex mechanobiological process as it is stimulated by the major factor of strains applied by body weight. The effect of screw heads and bodies as well as their pressure distribution is often overlooked. Hence, effective mechanical conditions of the healing process of tibia can be categorized into the material of the plate and screws, post-operation loadings, and screw type and pressure. In this paper, a mathematical biodegradation model was used to simulate the PGF/PLA plate-screw device over 8 weeks. The effect of different post-operation loading patterns was studied for both locking and non-locking screws. The aim was to reach the best configuration for the most achievable healing using FEA by computing the healing pattern, trend, and efficiency with the mechano-regulation theory based on deviatoric strain. The biodegradation process of the plate and screws resulted in 82% molecular weight loss and 1.05 GPa decrease in Young's modulus during 8 weeks. The healing efficiency of the cases ranged from 4.72% to 14.75% in the first week and 18.64% to 63.05% in the eighth week. Finally, an optimal case was achieved by considering the prevention of muscle erosion, bone density reduction, and nonunion, according to the obtained results.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal for Numerical Methods in Biomedical Engineering
International Journal for Numerical Methods in Biomedical Engineering ENGINEERING, BIOMEDICAL-MATHEMATICAL & COMPUTATIONAL BIOLOGY
CiteScore
4.50
自引率
9.50%
发文量
103
审稿时长
3 months
期刊介绍: All differential equation based models for biomedical applications and their novel solutions (using either established numerical methods such as finite difference, finite element and finite volume methods or new numerical methods) are within the scope of this journal. Manuscripts with experimental and analytical themes are also welcome if a component of the paper deals with numerical methods. Special cases that may not involve differential equations such as image processing, meshing and artificial intelligence are within the scope. Any research that is broadly linked to the wellbeing of the human body, either directly or indirectly, is also within the scope of this journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信