自适应两级非增益卡尔曼滤波器用于同步发电机在网络攻击测量条件下的动态状态估计

IF 5.7 1区 工程技术 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
Dongchen Hou;Yonghui Sun;Venkata Dinavahi;Yi Wang
{"title":"自适应两级非增益卡尔曼滤波器用于同步发电机在网络攻击测量条件下的动态状态估计","authors":"Dongchen Hou;Yonghui Sun;Venkata Dinavahi;Yi Wang","doi":"10.35833/MPCE.2023.000352","DOIUrl":null,"url":null,"abstract":"This paper develops an adaptive two-stage unscented Kalman filter (ATSUKF) to accurately track operation states of the synchronous generator (SG) under cyber attacks. To achieve high fidelity, considering the excitation system of SGs, a detailed 9\n<sup>th</sup>\n-order SG model for dynamic state estimation is established. Then, for several common cyber attacks against measurements, a two-stage unscented Kalman filter is proposed to estimate the model state and the bias in parallel. Subsequently, to solve the deterioration problem of state estimation performance caused by the mismatch between noise statistical characteristics and model assumptions, a multi-dimensional adaptive factor matrix is derived to modify the noise covariance matrix. Finally, a large number of simulation experiments are carried out on the IEEE 39-bus system, which shows that the proposed filter can accurately track the SG state under different abnormal test conditions.","PeriodicalId":51326,"journal":{"name":"Journal of Modern Power Systems and Clean Energy","volume":"12 5","pages":"1408-1418"},"PeriodicalIF":5.7000,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10419162","citationCount":"0","resultStr":"{\"title\":\"Adaptive Two-Stage Unscented Kalman Filter for Dynamic State Estimation of Synchronous Generator Under Cyber Attacks Against Measurements\",\"authors\":\"Dongchen Hou;Yonghui Sun;Venkata Dinavahi;Yi Wang\",\"doi\":\"10.35833/MPCE.2023.000352\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper develops an adaptive two-stage unscented Kalman filter (ATSUKF) to accurately track operation states of the synchronous generator (SG) under cyber attacks. To achieve high fidelity, considering the excitation system of SGs, a detailed 9\\n<sup>th</sup>\\n-order SG model for dynamic state estimation is established. Then, for several common cyber attacks against measurements, a two-stage unscented Kalman filter is proposed to estimate the model state and the bias in parallel. Subsequently, to solve the deterioration problem of state estimation performance caused by the mismatch between noise statistical characteristics and model assumptions, a multi-dimensional adaptive factor matrix is derived to modify the noise covariance matrix. Finally, a large number of simulation experiments are carried out on the IEEE 39-bus system, which shows that the proposed filter can accurately track the SG state under different abnormal test conditions.\",\"PeriodicalId\":51326,\"journal\":{\"name\":\"Journal of Modern Power Systems and Clean Energy\",\"volume\":\"12 5\",\"pages\":\"1408-1418\"},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2024-02-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10419162\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Modern Power Systems and Clean Energy\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10419162/\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Modern Power Systems and Clean Energy","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10419162/","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

本文开发了一种自适应两级无特征卡尔曼滤波器(ATSUKF),用于精确跟踪网络攻击下同步发电机(SG)的运行状态。为了实现高保真,考虑到 SG 的励磁系统,建立了详细的 9 阶 SG 模型,用于动态状态估计。然后,针对几种常见的针对测量的网络攻击,提出了一种两级无特征卡尔曼滤波器来并行估计模型状态和偏差。随后,为解决噪声统计特性与模型假设不匹配导致的状态估计性能下降问题,提出了一种多维自适应因子矩阵来修正噪声协方差矩阵。最后,在 IEEE 39-bus 系统上进行了大量仿真实验,结果表明所提出的滤波器能在不同的异常测试条件下准确跟踪 SG 状态。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Adaptive Two-Stage Unscented Kalman Filter for Dynamic State Estimation of Synchronous Generator Under Cyber Attacks Against Measurements
This paper develops an adaptive two-stage unscented Kalman filter (ATSUKF) to accurately track operation states of the synchronous generator (SG) under cyber attacks. To achieve high fidelity, considering the excitation system of SGs, a detailed 9 th -order SG model for dynamic state estimation is established. Then, for several common cyber attacks against measurements, a two-stage unscented Kalman filter is proposed to estimate the model state and the bias in parallel. Subsequently, to solve the deterioration problem of state estimation performance caused by the mismatch between noise statistical characteristics and model assumptions, a multi-dimensional adaptive factor matrix is derived to modify the noise covariance matrix. Finally, a large number of simulation experiments are carried out on the IEEE 39-bus system, which shows that the proposed filter can accurately track the SG state under different abnormal test conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Modern Power Systems and Clean Energy
Journal of Modern Power Systems and Clean Energy ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
12.30
自引率
14.30%
发文量
97
审稿时长
13 weeks
期刊介绍: Journal of Modern Power Systems and Clean Energy (MPCE), commencing from June, 2013, is a newly established, peer-reviewed and quarterly published journal in English. It is the first international power engineering journal originated in mainland China. MPCE publishes original papers, short letters and review articles in the field of modern power systems with focus on smart grid technology and renewable energy integration, etc.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信