用于可穿戴健康监测的带电流匹配和共模抑制回路的生物阻抗传感接口集成电路

IF 2.2 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
Risheng Su;Longbin Zhu;Wenjie Wang;Yang Zhou;Jianan Zheng;Zhengtao Zhu;Fan Luo;Siyuan Xie;Jihong Li;Zhijun Zhou;Fanyi Meng;Keping Wang
{"title":"用于可穿戴健康监测的带电流匹配和共模抑制回路的生物阻抗传感接口集成电路","authors":"Risheng Su;Longbin Zhu;Wenjie Wang;Yang Zhou;Jianan Zheng;Zhengtao Zhu;Fan Luo;Siyuan Xie;Jihong Li;Zhijun Zhou;Fanyi Meng;Keping Wang","doi":"10.1109/LSENS.2024.3457614","DOIUrl":null,"url":null,"abstract":"This letter presents a bioimpedance (Bio-Z) sensing interface IC with a current matching and common-mode suppressing (CMCS) loop for long-term health monitoring applications. The CMCS loop eliminates the mismatch between the source and sink stimulation currents of the current generator (CG), while reducing the area of the CG by half. Furthermore, the CMCS loop reuses the common-mode feedback loop of the Bio-Z instrumentation amplifier to substantially enhance the common-mode rejection ratio (CMRR) of the interface with reduced power consumption and area overhead. The proposed Bio-Z interface is designed in 130-nm CMOS technology. By employing the CMCS loop, it achieves a CMRR of 127 dB, exhibits a 3.84-mΩ/√Hz input-referred impedance noise, occupies an area of 0.07 mm\n<sup>2</sup>\n, and consumes a power of 10.4 µW for the readout front end and 12.9–122.7 µW for the CG.","PeriodicalId":13014,"journal":{"name":"IEEE Sensors Letters","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Bioimpedance Sensing Interface IC With Current Matching and Common-Mode Suppressing Loop for Wearable Health Monitoring\",\"authors\":\"Risheng Su;Longbin Zhu;Wenjie Wang;Yang Zhou;Jianan Zheng;Zhengtao Zhu;Fan Luo;Siyuan Xie;Jihong Li;Zhijun Zhou;Fanyi Meng;Keping Wang\",\"doi\":\"10.1109/LSENS.2024.3457614\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This letter presents a bioimpedance (Bio-Z) sensing interface IC with a current matching and common-mode suppressing (CMCS) loop for long-term health monitoring applications. The CMCS loop eliminates the mismatch between the source and sink stimulation currents of the current generator (CG), while reducing the area of the CG by half. Furthermore, the CMCS loop reuses the common-mode feedback loop of the Bio-Z instrumentation amplifier to substantially enhance the common-mode rejection ratio (CMRR) of the interface with reduced power consumption and area overhead. The proposed Bio-Z interface is designed in 130-nm CMOS technology. By employing the CMCS loop, it achieves a CMRR of 127 dB, exhibits a 3.84-mΩ/√Hz input-referred impedance noise, occupies an area of 0.07 mm\\n<sup>2</sup>\\n, and consumes a power of 10.4 µW for the readout front end and 12.9–122.7 µW for the CG.\",\"PeriodicalId\":13014,\"journal\":{\"name\":\"IEEE Sensors Letters\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Sensors Letters\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10670306/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Sensors Letters","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10670306/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

这封信介绍了一种生物阻抗(Bio-Z)传感接口集成电路,它具有电流匹配和共模抑制(CMCS)环路,适用于长期健康监测应用。CMCS 回路消除了电流发生器(CG)源和汇刺激电流之间的不匹配,同时将 CG 的面积减小了一半。此外,CMCS 回路还重新利用了 Bio-Z 仪表放大器的共模反馈回路,从而大幅提高了接口的共模抑制比 (CMRR),同时降低了功耗和面积开销。拟议的 Bio-Z 接口采用 130 纳米 CMOS 技术设计。通过采用 CMCS 回路,该接口的 CMRR 达到 127 dB,输入参考阻抗噪声为 3.84-mΩ/√Hz,占地面积为 0.07 mm2,读出前端的功耗为 10.4 µW,CG 的功耗为 12.9-122.7 µW。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Bioimpedance Sensing Interface IC With Current Matching and Common-Mode Suppressing Loop for Wearable Health Monitoring
This letter presents a bioimpedance (Bio-Z) sensing interface IC with a current matching and common-mode suppressing (CMCS) loop for long-term health monitoring applications. The CMCS loop eliminates the mismatch between the source and sink stimulation currents of the current generator (CG), while reducing the area of the CG by half. Furthermore, the CMCS loop reuses the common-mode feedback loop of the Bio-Z instrumentation amplifier to substantially enhance the common-mode rejection ratio (CMRR) of the interface with reduced power consumption and area overhead. The proposed Bio-Z interface is designed in 130-nm CMOS technology. By employing the CMCS loop, it achieves a CMRR of 127 dB, exhibits a 3.84-mΩ/√Hz input-referred impedance noise, occupies an area of 0.07 mm 2 , and consumes a power of 10.4 µW for the readout front end and 12.9–122.7 µW for the CG.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Sensors Letters
IEEE Sensors Letters Engineering-Electrical and Electronic Engineering
CiteScore
3.50
自引率
7.10%
发文量
194
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信