G Spacone, S Vostrikov, V Kartsch, S Benatti, L Benini, A Cossettini
{"title":"利用超低功耗可穿戴式 A 型超声波跟踪手腕和手部运动学。","authors":"G Spacone, S Vostrikov, V Kartsch, S Benatti, L Benini, A Cossettini","doi":"10.1109/TBCAS.2024.3465239","DOIUrl":null,"url":null,"abstract":"<p><p>Ultrasound-based Hand Gesture Recognition has gained significant attention in recent years. While static gesture recognition has been extensively explored, only a few works have tackled the task of movement regression for real-time tracking, despite its importance for the development of natural and smooth interaction strategies. In this paper, we demonstrate the regression of 3 hand-wrist Degrees of Freedom (DoFs) using a lightweight, A-mode-based, truly wearable US armband featuring four transducers and WULPUS, an ultra-low-power acquisition device. We collect US data, synchronized with an optical motion capture system to establish a ground truth, from 5 subjects. We achieve state-of-the-art performance with an average root-mean-squared-error (RMSE) of 7.32◦ ± 1.97◦ and mean-absolute-error (MAE) of 5.31◦ ± 1.42◦. Additionally, we demonstrate, for the first time, robustness with respect to transducer repositioning between acquisition sessions, achieving an average RMSE value of 11.11◦ ± 4.14◦ and a MAE of 8.46◦ ± 3.58◦. Finally, we deploy our pipeline on a real-time low-power microcontroller, showcasing the first instance of multi-DoF regression based on A-mode US data on an embedded device, with a power consumption lower than 30mW and end-to-end latency of ≈ 80 ms.</p>","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":"PP ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Tracking of Wrist and Hand Kinematics with Ultra Low Power Wearable A-mode Ultrasound.\",\"authors\":\"G Spacone, S Vostrikov, V Kartsch, S Benatti, L Benini, A Cossettini\",\"doi\":\"10.1109/TBCAS.2024.3465239\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Ultrasound-based Hand Gesture Recognition has gained significant attention in recent years. While static gesture recognition has been extensively explored, only a few works have tackled the task of movement regression for real-time tracking, despite its importance for the development of natural and smooth interaction strategies. In this paper, we demonstrate the regression of 3 hand-wrist Degrees of Freedom (DoFs) using a lightweight, A-mode-based, truly wearable US armband featuring four transducers and WULPUS, an ultra-low-power acquisition device. We collect US data, synchronized with an optical motion capture system to establish a ground truth, from 5 subjects. We achieve state-of-the-art performance with an average root-mean-squared-error (RMSE) of 7.32◦ ± 1.97◦ and mean-absolute-error (MAE) of 5.31◦ ± 1.42◦. Additionally, we demonstrate, for the first time, robustness with respect to transducer repositioning between acquisition sessions, achieving an average RMSE value of 11.11◦ ± 4.14◦ and a MAE of 8.46◦ ± 3.58◦. Finally, we deploy our pipeline on a real-time low-power microcontroller, showcasing the first instance of multi-DoF regression based on A-mode US data on an embedded device, with a power consumption lower than 30mW and end-to-end latency of ≈ 80 ms.</p>\",\"PeriodicalId\":94031,\"journal\":{\"name\":\"IEEE transactions on biomedical circuits and systems\",\"volume\":\"PP \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE transactions on biomedical circuits and systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TBCAS.2024.3465239\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on biomedical circuits and systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TBCAS.2024.3465239","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
近年来,基于超声波的手势识别技术备受关注。尽管静态手势识别已被广泛探索,但只有少数作品解决了实时跟踪的运动回归任务,尽管这对开发自然流畅的交互策略非常重要。在本文中,我们展示了使用轻便、基于 A 模式、真正可穿戴的 US 臂带和 WULPUS(一种超低功耗采集设备)对 3 个手腕自由度(DoF)进行回归。我们收集了 5 名受试者的 US 数据,并与光学运动捕捉系统同步,以建立地面实况。我们实现了最先进的性能,平均均方根误差 (RMSE) 为 7.32◦ ± 1.97◦,平均绝对误差 (MAE) 为 5.31◦ ± 1.42◦。此外,我们首次证明了采集过程之间传感器重新定位的鲁棒性,平均 RMSE 值为 11.11◦ ± 4.14◦,MAE 为 8.46◦ ± 3.58◦。最后,我们在实时低功耗微控制器上部署了我们的流水线,首次在嵌入式设备上展示了基于 A 模式 US 数据的多 DoF 回归,功耗低于 30mW,端到端延迟≈ 80 ms。
Tracking of Wrist and Hand Kinematics with Ultra Low Power Wearable A-mode Ultrasound.
Ultrasound-based Hand Gesture Recognition has gained significant attention in recent years. While static gesture recognition has been extensively explored, only a few works have tackled the task of movement regression for real-time tracking, despite its importance for the development of natural and smooth interaction strategies. In this paper, we demonstrate the regression of 3 hand-wrist Degrees of Freedom (DoFs) using a lightweight, A-mode-based, truly wearable US armband featuring four transducers and WULPUS, an ultra-low-power acquisition device. We collect US data, synchronized with an optical motion capture system to establish a ground truth, from 5 subjects. We achieve state-of-the-art performance with an average root-mean-squared-error (RMSE) of 7.32◦ ± 1.97◦ and mean-absolute-error (MAE) of 5.31◦ ± 1.42◦. Additionally, we demonstrate, for the first time, robustness with respect to transducer repositioning between acquisition sessions, achieving an average RMSE value of 11.11◦ ± 4.14◦ and a MAE of 8.46◦ ± 3.58◦. Finally, we deploy our pipeline on a real-time low-power microcontroller, showcasing the first instance of multi-DoF regression based on A-mode US data on an embedded device, with a power consumption lower than 30mW and end-to-end latency of ≈ 80 ms.