{"title":"表面肌电图结合脊柱三维数据系统评估脊柱侧弯的有效性研究。","authors":"Li-Huang Zhang, Yong Bao, Xiao-Pei Sun, Jie-Jian Shi, Jie Zhang, Jing-Yun Xu, Qing Xie","doi":"10.62347/BLSO4420","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the clinical effectiveness of surface electromyography combined with a spine 3D data system.</p><p><strong>Methods: </strong>10 idiopathic scoliosis patients (age: 12.90±3.67 years, height: 155.90±20.07 cm, weight: 48.00±12.86 kg, 6 major thoracic lateral bends and 4 lumbar bends) who were selected to attend the outpatient clinic of Ruijin Rehabilitation Hospital, First diagnosed as scoliosis by imaging examination (EOS system), evaluation by using the surface electromyography monitoring system, the radiation-free 3D spine data acquisition and analysis system, the surface electromyography of the paravertebral muscles (root mean square value (RMS) of the resting standing and action position of the spine) and the Cobb angle of scoliosis were recorded.</p><p><strong>Results: </strong>The RMS of the convex side was larger than that of the concave side in the two postures (P<0.05), and The RMS value of bilateral action position was significantly higher than that of rest position (P<0.05). There was no correlation between RMS ratio and Cobb angle in two positions of thoracic scoliosis (P>0.05). There was a significant correlation between the RMS ratio at rest position of lumbar scoliosis and Cobb angle. At rest, the RMS value of convex side was significantly correlated with the Cobb angle measured by the EOS system and the 3D data system (P<0.05, of which P<0.01). The Cobb angle measured by 3D data system and the EOS system was significantly correlated (P<0.01).</p><p><strong>Conclusion: </strong>Surface EMG can be used to evaluate the motor function of paravertebral muscles on both sides of scoliosis patients. The new 3D data system has high accuracy in evaluating scoliosis. The combination of the two can dynamically evaluate scoliosis, which is more clinically effective.</p>","PeriodicalId":72163,"journal":{"name":"American journal of clinical and experimental immunology","volume":"13 4","pages":"195-201"},"PeriodicalIF":1.4000,"publicationDate":"2024-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11411156/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effectiveness study of surface electromyography combined with spine 3D data system to evaluate scoliosis.\",\"authors\":\"Li-Huang Zhang, Yong Bao, Xiao-Pei Sun, Jie-Jian Shi, Jie Zhang, Jing-Yun Xu, Qing Xie\",\"doi\":\"10.62347/BLSO4420\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To evaluate the clinical effectiveness of surface electromyography combined with a spine 3D data system.</p><p><strong>Methods: </strong>10 idiopathic scoliosis patients (age: 12.90±3.67 years, height: 155.90±20.07 cm, weight: 48.00±12.86 kg, 6 major thoracic lateral bends and 4 lumbar bends) who were selected to attend the outpatient clinic of Ruijin Rehabilitation Hospital, First diagnosed as scoliosis by imaging examination (EOS system), evaluation by using the surface electromyography monitoring system, the radiation-free 3D spine data acquisition and analysis system, the surface electromyography of the paravertebral muscles (root mean square value (RMS) of the resting standing and action position of the spine) and the Cobb angle of scoliosis were recorded.</p><p><strong>Results: </strong>The RMS of the convex side was larger than that of the concave side in the two postures (P<0.05), and The RMS value of bilateral action position was significantly higher than that of rest position (P<0.05). There was no correlation between RMS ratio and Cobb angle in two positions of thoracic scoliosis (P>0.05). There was a significant correlation between the RMS ratio at rest position of lumbar scoliosis and Cobb angle. At rest, the RMS value of convex side was significantly correlated with the Cobb angle measured by the EOS system and the 3D data system (P<0.05, of which P<0.01). The Cobb angle measured by 3D data system and the EOS system was significantly correlated (P<0.01).</p><p><strong>Conclusion: </strong>Surface EMG can be used to evaluate the motor function of paravertebral muscles on both sides of scoliosis patients. The new 3D data system has high accuracy in evaluating scoliosis. The combination of the two can dynamically evaluate scoliosis, which is more clinically effective.</p>\",\"PeriodicalId\":72163,\"journal\":{\"name\":\"American journal of clinical and experimental immunology\",\"volume\":\"13 4\",\"pages\":\"195-201\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-08-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11411156/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of clinical and experimental immunology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.62347/BLSO4420\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"IMMUNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of clinical and experimental immunology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.62347/BLSO4420","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
目的:评估表面肌电图与脊柱三维数据系统相结合的临床效果:方法:选取10例特发性脊柱侧弯患者(年龄:12.90±3.67岁,身高:155.90±20.07cm,体重:48.00±12.86 kg,胸大弯6例,腰大弯4例),经影像学检查(EOS系统)确诊为脊柱侧弯,采用表面肌电监测系统、无辐射三维脊柱数据采集分析系统进行评估,记录椎旁肌表面肌电(脊柱静止站立位和活动位的均方根值)和脊柱侧弯的Cobb角:两种姿势下,凸侧的均方根值均大于凹侧(P0.05)。腰椎侧弯静息姿势下的有效值比与 Cobb 角之间存在明显的相关性。在静息状态下,凸侧的 RMS 值与 EOS 系统和三维数据系统测量的 Cobb 角有明显相关性(PC结论:表面肌电图可用于评估脊柱侧凸患者两侧椎旁肌肉的运动功能。新的三维数据系统在评估脊柱侧弯方面具有很高的准确性。两者结合可动态评估脊柱侧弯,临床效果更好。
Effectiveness study of surface electromyography combined with spine 3D data system to evaluate scoliosis.
Objective: To evaluate the clinical effectiveness of surface electromyography combined with a spine 3D data system.
Methods: 10 idiopathic scoliosis patients (age: 12.90±3.67 years, height: 155.90±20.07 cm, weight: 48.00±12.86 kg, 6 major thoracic lateral bends and 4 lumbar bends) who were selected to attend the outpatient clinic of Ruijin Rehabilitation Hospital, First diagnosed as scoliosis by imaging examination (EOS system), evaluation by using the surface electromyography monitoring system, the radiation-free 3D spine data acquisition and analysis system, the surface electromyography of the paravertebral muscles (root mean square value (RMS) of the resting standing and action position of the spine) and the Cobb angle of scoliosis were recorded.
Results: The RMS of the convex side was larger than that of the concave side in the two postures (P<0.05), and The RMS value of bilateral action position was significantly higher than that of rest position (P<0.05). There was no correlation between RMS ratio and Cobb angle in two positions of thoracic scoliosis (P>0.05). There was a significant correlation between the RMS ratio at rest position of lumbar scoliosis and Cobb angle. At rest, the RMS value of convex side was significantly correlated with the Cobb angle measured by the EOS system and the 3D data system (P<0.05, of which P<0.01). The Cobb angle measured by 3D data system and the EOS system was significantly correlated (P<0.01).
Conclusion: Surface EMG can be used to evaluate the motor function of paravertebral muscles on both sides of scoliosis patients. The new 3D data system has high accuracy in evaluating scoliosis. The combination of the two can dynamically evaluate scoliosis, which is more clinically effective.