从髋关节深屈开始单侧伸展时髋关节运动学的性别差异和不对称。

IF 1.7 4区 医学 Q4 BIOPHYSICS
Camille Johnson, Ethan Ruh, Naomi Frankston, Shaquille Charles, Michael McClincy, William Anderst
{"title":"从髋关节深屈开始单侧伸展时髋关节运动学的性别差异和不对称。","authors":"Camille Johnson, Ethan Ruh, Naomi Frankston, Shaquille Charles, Michael McClincy, William Anderst","doi":"10.1115/1.4066466","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study was to identify side-to-side and sex-based differences in hip kinematics during a unilateral step-up from deep flexion. Twelve (8 men, 4 women) asymptomatic young adults performed a step ascent motion while synchronized biplane radiographs of the hip were collected at 50 images per second. Femur and pelvis position were determined using a validated volumetric model-based tracking technique that matched digitally reconstructed radiographs created from subject-specific computed tomography (CT) bone models to each pair of synchronized radiographs. Hip kinematics and side-to-side differences were calculated and a linear mixed effects model evaluated sex-based differences. Women were on average 10.2° more abducted and 0.2mm more medially translated than men across the step up motion (p<0.001). Asymmetry between hips was up to 14.1 ± 12.1° in internal rotation and 1.3 ± 1.4mm in translation. This dataset demonstrates the inherent asymmetry during movements involving unilateral hip extension from deep flexion and may be used provide context for observed kinematics differences following surgery or rehabilitation. Previously reported kinematic differences between total hip arthroplasty and contralateral hips may be well within the natural side-to-side differences that exist in asymptomatic native hips.</p>","PeriodicalId":54871,"journal":{"name":"Journal of Biomechanical Engineering-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sex-Based Differences and Asymmetry in Hip Kinematics During Unilateral Extension from Deep Hip Flexion.\",\"authors\":\"Camille Johnson, Ethan Ruh, Naomi Frankston, Shaquille Charles, Michael McClincy, William Anderst\",\"doi\":\"10.1115/1.4066466\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of this study was to identify side-to-side and sex-based differences in hip kinematics during a unilateral step-up from deep flexion. Twelve (8 men, 4 women) asymptomatic young adults performed a step ascent motion while synchronized biplane radiographs of the hip were collected at 50 images per second. Femur and pelvis position were determined using a validated volumetric model-based tracking technique that matched digitally reconstructed radiographs created from subject-specific computed tomography (CT) bone models to each pair of synchronized radiographs. Hip kinematics and side-to-side differences were calculated and a linear mixed effects model evaluated sex-based differences. Women were on average 10.2° more abducted and 0.2mm more medially translated than men across the step up motion (p<0.001). Asymmetry between hips was up to 14.1 ± 12.1° in internal rotation and 1.3 ± 1.4mm in translation. This dataset demonstrates the inherent asymmetry during movements involving unilateral hip extension from deep flexion and may be used provide context for observed kinematics differences following surgery or rehabilitation. Previously reported kinematic differences between total hip arthroplasty and contralateral hips may be well within the natural side-to-side differences that exist in asymptomatic native hips.</p>\",\"PeriodicalId\":54871,\"journal\":{\"name\":\"Journal of Biomechanical Engineering-Transactions of the Asme\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-09-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomechanical Engineering-Transactions of the Asme\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4066466\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomechanical Engineering-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4066466","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是确定单侧深屈上台阶时髋关节运动学的侧向和性别差异。12名(8名男性,4名女性)无症状的年轻成年人在以每秒50张图像的速度同步采集髋部双平面X光片的同时,进行了台阶上升运动。股骨和骨盆的位置是通过一种经过验证的基于容积模型的跟踪技术确定的,该技术可将由特定受试者的计算机断层扫描(CT)骨骼模型创建的数字重建X光片与每对同步X光片相匹配。计算髋关节运动学和侧向差异,并利用线性混合效应模型评估性别差异。在整个上台阶运动中,女性比男性平均多外展 10.2°,多内旋 0.2 毫米(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Sex-Based Differences and Asymmetry in Hip Kinematics During Unilateral Extension from Deep Hip Flexion.

The purpose of this study was to identify side-to-side and sex-based differences in hip kinematics during a unilateral step-up from deep flexion. Twelve (8 men, 4 women) asymptomatic young adults performed a step ascent motion while synchronized biplane radiographs of the hip were collected at 50 images per second. Femur and pelvis position were determined using a validated volumetric model-based tracking technique that matched digitally reconstructed radiographs created from subject-specific computed tomography (CT) bone models to each pair of synchronized radiographs. Hip kinematics and side-to-side differences were calculated and a linear mixed effects model evaluated sex-based differences. Women were on average 10.2° more abducted and 0.2mm more medially translated than men across the step up motion (p<0.001). Asymmetry between hips was up to 14.1 ± 12.1° in internal rotation and 1.3 ± 1.4mm in translation. This dataset demonstrates the inherent asymmetry during movements involving unilateral hip extension from deep flexion and may be used provide context for observed kinematics differences following surgery or rehabilitation. Previously reported kinematic differences between total hip arthroplasty and contralateral hips may be well within the natural side-to-side differences that exist in asymptomatic native hips.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.40
自引率
5.90%
发文量
169
审稿时长
4-8 weeks
期刊介绍: Artificial Organs and Prostheses; Bioinstrumentation and Measurements; Bioheat Transfer; Biomaterials; Biomechanics; Bioprocess Engineering; Cellular Mechanics; Design and Control of Biological Systems; Physiological Systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信