Krisna Lorena Sandino-Lacayo, Marina Vega-González, Ana Isabel Soza-Bolaños, Laura Celeste Herrera-Alaniz, Taher Al Omari, Rubén Abraham Domínguez-Pérez
{"title":"用不同热处理方法制造的两种小儿旋转锉的循环疲劳抗力:体外研究。","authors":"Krisna Lorena Sandino-Lacayo, Marina Vega-González, Ana Isabel Soza-Bolaños, Laura Celeste Herrera-Alaniz, Taher Al Omari, Rubén Abraham Domínguez-Pérez","doi":"10.22514/jocpd.2024.109","DOIUrl":null,"url":null,"abstract":"<p><p>Nickel-titanium (NiTi) instruments offer many advantages during endodontic instrumentation; however, the fracture risk within the canal remains a concern. Manufacturers continuously develop and introduce instruments to the market with supposedly enhanced cyclic fatigue resistance and increased flexibility, achieved through different proprietary manufacturing processes, the details of which have not been made public. In recent years, two rotary systems specially designed for deciduous teeth have been commercially available, but information about their performance is lacking. This investigation aimed to identify which manufacturing process provides better cyclic fatigue resistance: the AF-H Wire technology used in the AF baby rotary files (AF-f) or the CM-Wire technology used in the i3 Gold deciduous teeth rotary files (i3G-f). Forty rotary International Organization for Standardization (ISO) 25/04 files were tested in artificial canals with a standard geometry of 60° angle and 2.5 mm radius until fracture. The number of cycles to fracture was calculated, and the length of the fragments was measured. A scanning electron microscope (SEM) was used to examine the fracture surfaces and fragments. Energy dispersive spectroscopy (EDS) was used to determine the percentage weight of NiTi in each file. The statistical analysis (Mann-Whitney test) showed that the cyclic fatigue resistance of the AF-f was significantly higher (<i>p</i> < 0.0001) than that of the i3G-f. Additionally, there was a significant difference (<i>p</i> = 0.0419) in the length of the fractured fragments. All instruments showed one or more types of manufacturing defects and presented similar NiTi percentages by weight. The manufacturing process is critical to cyclic fatigue resistance, and there seems to be responsible for the difference in cyclic fatigue resistance between these similar instruments.</p>","PeriodicalId":50235,"journal":{"name":"Journal of Clinical Pediatric Dentistry","volume":"48 5","pages":"102-109"},"PeriodicalIF":1.5000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cyclic fatigue resistance of two pediatric rotary files manufactured with different heat treatments: an <i>in-vitro</i> study.\",\"authors\":\"Krisna Lorena Sandino-Lacayo, Marina Vega-González, Ana Isabel Soza-Bolaños, Laura Celeste Herrera-Alaniz, Taher Al Omari, Rubén Abraham Domínguez-Pérez\",\"doi\":\"10.22514/jocpd.2024.109\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Nickel-titanium (NiTi) instruments offer many advantages during endodontic instrumentation; however, the fracture risk within the canal remains a concern. Manufacturers continuously develop and introduce instruments to the market with supposedly enhanced cyclic fatigue resistance and increased flexibility, achieved through different proprietary manufacturing processes, the details of which have not been made public. In recent years, two rotary systems specially designed for deciduous teeth have been commercially available, but information about their performance is lacking. This investigation aimed to identify which manufacturing process provides better cyclic fatigue resistance: the AF-H Wire technology used in the AF baby rotary files (AF-f) or the CM-Wire technology used in the i3 Gold deciduous teeth rotary files (i3G-f). Forty rotary International Organization for Standardization (ISO) 25/04 files were tested in artificial canals with a standard geometry of 60° angle and 2.5 mm radius until fracture. The number of cycles to fracture was calculated, and the length of the fragments was measured. A scanning electron microscope (SEM) was used to examine the fracture surfaces and fragments. Energy dispersive spectroscopy (EDS) was used to determine the percentage weight of NiTi in each file. The statistical analysis (Mann-Whitney test) showed that the cyclic fatigue resistance of the AF-f was significantly higher (<i>p</i> < 0.0001) than that of the i3G-f. Additionally, there was a significant difference (<i>p</i> = 0.0419) in the length of the fractured fragments. All instruments showed one or more types of manufacturing defects and presented similar NiTi percentages by weight. The manufacturing process is critical to cyclic fatigue resistance, and there seems to be responsible for the difference in cyclic fatigue resistance between these similar instruments.</p>\",\"PeriodicalId\":50235,\"journal\":{\"name\":\"Journal of Clinical Pediatric Dentistry\",\"volume\":\"48 5\",\"pages\":\"102-109\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Pediatric Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.22514/jocpd.2024.109\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Pediatric Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.22514/jocpd.2024.109","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Cyclic fatigue resistance of two pediatric rotary files manufactured with different heat treatments: an in-vitro study.
Nickel-titanium (NiTi) instruments offer many advantages during endodontic instrumentation; however, the fracture risk within the canal remains a concern. Manufacturers continuously develop and introduce instruments to the market with supposedly enhanced cyclic fatigue resistance and increased flexibility, achieved through different proprietary manufacturing processes, the details of which have not been made public. In recent years, two rotary systems specially designed for deciduous teeth have been commercially available, but information about their performance is lacking. This investigation aimed to identify which manufacturing process provides better cyclic fatigue resistance: the AF-H Wire technology used in the AF baby rotary files (AF-f) or the CM-Wire technology used in the i3 Gold deciduous teeth rotary files (i3G-f). Forty rotary International Organization for Standardization (ISO) 25/04 files were tested in artificial canals with a standard geometry of 60° angle and 2.5 mm radius until fracture. The number of cycles to fracture was calculated, and the length of the fragments was measured. A scanning electron microscope (SEM) was used to examine the fracture surfaces and fragments. Energy dispersive spectroscopy (EDS) was used to determine the percentage weight of NiTi in each file. The statistical analysis (Mann-Whitney test) showed that the cyclic fatigue resistance of the AF-f was significantly higher (p < 0.0001) than that of the i3G-f. Additionally, there was a significant difference (p = 0.0419) in the length of the fractured fragments. All instruments showed one or more types of manufacturing defects and presented similar NiTi percentages by weight. The manufacturing process is critical to cyclic fatigue resistance, and there seems to be responsible for the difference in cyclic fatigue resistance between these similar instruments.
期刊介绍:
The purpose of The Journal of Clinical Pediatric Dentistry is to provide clinically relevant information to enable the practicing dentist to have access to the state of the art in pediatric dentistry.
From prevention, to information, to the management of different problems encountered in children''s related medical and dental problems, this peer-reviewed journal keeps you abreast of the latest news and developments related to pediatric dentistry.