{"title":"用于系统探索经胫骨生物关节假体设计的机器人仿真器。","authors":"Anthony J Anderson, Kira A Gauthier, Mathew Sunil Varre, Kimberly A Nickerson, Brittney C Muir, Patrick M Aubin","doi":"10.1177/20556683241280733","DOIUrl":null,"url":null,"abstract":"<p><p>People with transtibial limb loss frequently experience suboptimal gait outcomes. This is partly attributable to the absence of the biarticular gastrocnemius muscle, which plays a unique role in walking. Although a recent surge of biarticular prostheses aims to restore gastrocnemius function, the broad design space and lack of consensus on optimal hardware and control strategies present scientific and engineering challenges. This study introduces a robotic biarticular prosthesis emulator, comprising a uniarticular ankle-foot prosthesis and knee flexion exoskeleton, each actuated by a custom off-board system. Benchtop experiments were conducted to characterize the emulator's mechatronic performance. Walking experiments with one transtibial amputee demonstrated the system's capability to provide knee and ankle assistance. The -3 dB bandwidths for the knee exoskeleton's torque and motor velocity controllers were measured at approximately 5 Hz and 100 Hz, respectively. A feedforward iterative learning controller reduced the root-mean-squared torque tracking error from 6.04 Nm to 0.99 Nm in hardware-in-the-loop experiments, an 84% improvement. User-preference-based tuning yielded a peak knee torque of approximately 20% of the estimated biological knee moment. This biarticular prosthesis emulator demonstrates significant potential as a versatile research platform that can offer valuable insights for the advancement of lower-limb assistive devices.</p>","PeriodicalId":43319,"journal":{"name":"Journal of Rehabilitation and Assistive Technologies Engineering","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11406492/pdf/","citationCount":"0","resultStr":"{\"title\":\"A robotic emulator for the systematic exploration of transtibial biarticular prosthesis designs.\",\"authors\":\"Anthony J Anderson, Kira A Gauthier, Mathew Sunil Varre, Kimberly A Nickerson, Brittney C Muir, Patrick M Aubin\",\"doi\":\"10.1177/20556683241280733\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>People with transtibial limb loss frequently experience suboptimal gait outcomes. This is partly attributable to the absence of the biarticular gastrocnemius muscle, which plays a unique role in walking. Although a recent surge of biarticular prostheses aims to restore gastrocnemius function, the broad design space and lack of consensus on optimal hardware and control strategies present scientific and engineering challenges. This study introduces a robotic biarticular prosthesis emulator, comprising a uniarticular ankle-foot prosthesis and knee flexion exoskeleton, each actuated by a custom off-board system. Benchtop experiments were conducted to characterize the emulator's mechatronic performance. Walking experiments with one transtibial amputee demonstrated the system's capability to provide knee and ankle assistance. The -3 dB bandwidths for the knee exoskeleton's torque and motor velocity controllers were measured at approximately 5 Hz and 100 Hz, respectively. A feedforward iterative learning controller reduced the root-mean-squared torque tracking error from 6.04 Nm to 0.99 Nm in hardware-in-the-loop experiments, an 84% improvement. User-preference-based tuning yielded a peak knee torque of approximately 20% of the estimated biological knee moment. This biarticular prosthesis emulator demonstrates significant potential as a versatile research platform that can offer valuable insights for the advancement of lower-limb assistive devices.</p>\",\"PeriodicalId\":43319,\"journal\":{\"name\":\"Journal of Rehabilitation and Assistive Technologies Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11406492/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Rehabilitation and Assistive Technologies Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/20556683241280733\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Rehabilitation and Assistive Technologies Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/20556683241280733","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

经胫腓骨肢体缺失患者经常会出现步态不理想的情况。这部分归因于生物关节腓肠肌的缺失,而腓肠肌在行走中发挥着独特的作用。尽管最近涌现出了大量旨在恢复腓肠肌功能的生物关节假肢,但由于设计空间广阔,且对最佳硬件和控制策略缺乏共识,因此给科学和工程设计带来了挑战。本研究介绍了一种机器人生物关节假肢仿真器,它由单关节踝足假肢和膝关节屈曲外骨骼组成,每个假肢都由一个定制的板外系统驱动。为鉴定仿真器的机电性能,进行了台式实验。一名经胫截肢者的行走实验证明了该系统提供膝关节和踝关节辅助的能力。膝关节外骨骼的扭矩和电机速度控制器的 -3 dB 带宽分别约为 5 Hz 和 100 Hz。在硬件在环实验中,前馈迭代学习控制器将扭矩跟踪的均方根误差从 6.04 牛米降低到 0.99 牛米,提高了 84%。基于用户偏好的调整使膝关节峰值扭矩约为估计生物膝关节力矩的 20%。这个生物关节假肢模拟器作为一个多功能研究平台,为下肢辅助设备的发展提供了宝贵的见解,显示出巨大的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A robotic emulator for the systematic exploration of transtibial biarticular prosthesis designs.

People with transtibial limb loss frequently experience suboptimal gait outcomes. This is partly attributable to the absence of the biarticular gastrocnemius muscle, which plays a unique role in walking. Although a recent surge of biarticular prostheses aims to restore gastrocnemius function, the broad design space and lack of consensus on optimal hardware and control strategies present scientific and engineering challenges. This study introduces a robotic biarticular prosthesis emulator, comprising a uniarticular ankle-foot prosthesis and knee flexion exoskeleton, each actuated by a custom off-board system. Benchtop experiments were conducted to characterize the emulator's mechatronic performance. Walking experiments with one transtibial amputee demonstrated the system's capability to provide knee and ankle assistance. The -3 dB bandwidths for the knee exoskeleton's torque and motor velocity controllers were measured at approximately 5 Hz and 100 Hz, respectively. A feedforward iterative learning controller reduced the root-mean-squared torque tracking error from 6.04 Nm to 0.99 Nm in hardware-in-the-loop experiments, an 84% improvement. User-preference-based tuning yielded a peak knee torque of approximately 20% of the estimated biological knee moment. This biarticular prosthesis emulator demonstrates significant potential as a versatile research platform that can offer valuable insights for the advancement of lower-limb assistive devices.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
5.00%
发文量
37
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信