Ghazal Ameli, Tanja Hüsch, Wilhelm A Hübner, Peter Weibl
{"title":"治疗男性压力性尿失禁的新型可调节人工尿道括约肌(VictoTM):初步临床结果。","authors":"Ghazal Ameli, Tanja Hüsch, Wilhelm A Hübner, Peter Weibl","doi":"10.21037/tau-22-779","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Artificial urinary sphinkter (AUS) are still the gold standard for treatment of male stress urinary incontinence with good clinical outcomes and high patient's reported satisfaction rate. However, more than half of the patients with an AUS will require additional procedures, most likely revisions. To introduce a novel adjustable AUS for treatment of male stress urinary incontinence and perform a preliminary clinical investigation to determine the safety and efficacy of the device.</p><p><strong>Methods: </strong>Men with urodynamically proven SUI following radical prostatectomy (RP), transurethral resection of prostate (TURP) and pelvic injuries were implanted with the Victo-AUS. Patients with three or more previous incontinence surgeries were excluded from the series. Patients were monitored over a mean follow up of 29 months (range, 13.7-47.9 months). The device was tested for efficacy by using objective measurements of urinary leakage and continence. We used validated questionnaires at baseline and clinical follow-ups. The key outcomes were overall improvement, patients reported satisfaction and complication rate.</p><p><strong>Results: </strong>A total of 88 patients between December 2016 and December 2019 have been enrolled in this trial. Improvement was defined as a reduction in pad usage per day (p/d) over 50% compared to baseline. In total, 70 (88%) patients were reported to be improved. Treatment success according to the definition of 0-1 p/d was accomplished in 56 (70%) patients. Urethral erosion, infection or mechanical failure occurred in 4 (5%), 4 (5%) and 1 (1.3%) patient respectively. Explantation of the device was mandatory in 6 patients due to erosion, infection or mechanical failure.</p><p><strong>Conclusions: </strong>In this series, a continence rate of 70% was achieved with an acceptable complication-rate. These results together with a high satisfaction rate demonstrate effectiveness and safety of the Victo system in mid-term follow-up for the treatment of male SUI.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11399051/pdf/","citationCount":"0","resultStr":"{\"title\":\"A new adjustable artificial urinary sphincter for male stress urinary incontinence (Victo<sup>TM</sup>): preliminary clinical results.\",\"authors\":\"Ghazal Ameli, Tanja Hüsch, Wilhelm A Hübner, Peter Weibl\",\"doi\":\"10.21037/tau-22-779\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Artificial urinary sphinkter (AUS) are still the gold standard for treatment of male stress urinary incontinence with good clinical outcomes and high patient's reported satisfaction rate. However, more than half of the patients with an AUS will require additional procedures, most likely revisions. To introduce a novel adjustable AUS for treatment of male stress urinary incontinence and perform a preliminary clinical investigation to determine the safety and efficacy of the device.</p><p><strong>Methods: </strong>Men with urodynamically proven SUI following radical prostatectomy (RP), transurethral resection of prostate (TURP) and pelvic injuries were implanted with the Victo-AUS. Patients with three or more previous incontinence surgeries were excluded from the series. Patients were monitored over a mean follow up of 29 months (range, 13.7-47.9 months). The device was tested for efficacy by using objective measurements of urinary leakage and continence. We used validated questionnaires at baseline and clinical follow-ups. The key outcomes were overall improvement, patients reported satisfaction and complication rate.</p><p><strong>Results: </strong>A total of 88 patients between December 2016 and December 2019 have been enrolled in this trial. Improvement was defined as a reduction in pad usage per day (p/d) over 50% compared to baseline. In total, 70 (88%) patients were reported to be improved. Treatment success according to the definition of 0-1 p/d was accomplished in 56 (70%) patients. Urethral erosion, infection or mechanical failure occurred in 4 (5%), 4 (5%) and 1 (1.3%) patient respectively. Explantation of the device was mandatory in 6 patients due to erosion, infection or mechanical failure.</p><p><strong>Conclusions: </strong>In this series, a continence rate of 70% was achieved with an acceptable complication-rate. These results together with a high satisfaction rate demonstrate effectiveness and safety of the Victo system in mid-term follow-up for the treatment of male SUI.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11399051/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.21037/tau-22-779\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21037/tau-22-779","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/9 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
摘要
背景:人工尿道海绵体(AUS)仍是治疗男性压力性尿失禁的金标准,临床疗效好,患者满意度高。然而,半数以上使用 AUS 的患者需要进行其他手术,最有可能的是翻修。目的:引进一种新型可调节 AUS 用于治疗男性压力性尿失禁,并进行初步临床调查以确定该装置的安全性和有效性:方法:为根治性前列腺切除术(RP)、经尿道前列腺切除术(TURP)和骨盆损伤后经尿动力学证实患有 SUI 的男性患者植入 Victo-AUS。曾接受过三次或三次以上尿失禁手术的患者被排除在系列研究之外。患者的平均随访时间为 29 个月(13.7-47.9 个月)。通过对漏尿和尿失禁情况的客观测量,对该装置的疗效进行了测试。我们在基线和临床随访中使用了经过验证的调查问卷。主要结果包括总体改善、患者满意度和并发症发生率:在 2016 年 12 月至 2019 年 12 月期间,共有 88 名患者参与了这项试验。与基线相比,改善的定义是每日尿垫使用量(p/d)减少 50%以上。据报告,共有 70 名(88%)患者病情得到改善。根据 0-1 p/d 的定义,56 名(70%)患者治疗成功。分别有 4 名(5%)、4 名(5%)和 1 名(1.3%)患者出现尿道侵蚀、感染或机械故障。有 6 名患者因发生侵蚀、感染或机械故障而必须拆除装置:在这一系列手术中,尿失禁率达到 70%,并发症发生率在可接受范围内。这些结果以及较高的满意度证明了 Victo 系统在治疗男性 SUI 的中期随访中的有效性和安全性。
A new adjustable artificial urinary sphincter for male stress urinary incontinence (VictoTM): preliminary clinical results.
Background: Artificial urinary sphinkter (AUS) are still the gold standard for treatment of male stress urinary incontinence with good clinical outcomes and high patient's reported satisfaction rate. However, more than half of the patients with an AUS will require additional procedures, most likely revisions. To introduce a novel adjustable AUS for treatment of male stress urinary incontinence and perform a preliminary clinical investigation to determine the safety and efficacy of the device.
Methods: Men with urodynamically proven SUI following radical prostatectomy (RP), transurethral resection of prostate (TURP) and pelvic injuries were implanted with the Victo-AUS. Patients with three or more previous incontinence surgeries were excluded from the series. Patients were monitored over a mean follow up of 29 months (range, 13.7-47.9 months). The device was tested for efficacy by using objective measurements of urinary leakage and continence. We used validated questionnaires at baseline and clinical follow-ups. The key outcomes were overall improvement, patients reported satisfaction and complication rate.
Results: A total of 88 patients between December 2016 and December 2019 have been enrolled in this trial. Improvement was defined as a reduction in pad usage per day (p/d) over 50% compared to baseline. In total, 70 (88%) patients were reported to be improved. Treatment success according to the definition of 0-1 p/d was accomplished in 56 (70%) patients. Urethral erosion, infection or mechanical failure occurred in 4 (5%), 4 (5%) and 1 (1.3%) patient respectively. Explantation of the device was mandatory in 6 patients due to erosion, infection or mechanical failure.
Conclusions: In this series, a continence rate of 70% was achieved with an acceptable complication-rate. These results together with a high satisfaction rate demonstrate effectiveness and safety of the Victo system in mid-term follow-up for the treatment of male SUI.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.