{"title":"基于无低温方案的低温太赫兹扫描隧道显微镜的开发。","authors":"Huaiyu Zhang, Dacheng Tian, Yang Zhan, Zijia Liu, Chen Ma, Yuwu Zhang, Jianwei Hu, Xiaoyue He, Baojie Feng, Yiqi Zhang, Lan Chen, Peng Cheng, Kehui Wu","doi":"10.1063/5.0208689","DOIUrl":null,"url":null,"abstract":"<p><p>We have developed a cryogen-free, low-temperature terahertz scanning tunneling microscope (THz-STM). This system utilizes a continuous-flow cryogen-free cooler to achieve low temperatures of ∼25 K. Meanwhile, an ultra-small ultra-high vacuum chamber results in the reduction of the distance from sample to viewport to only 4 cm. NA = 0.6 can be achieved while placing the entire optical component, including a large parabolic mirror, outside the vacuum chamber. Thus, the convenience of optical coupling is much improved without compromising the performance of STM. Based on this, we introduced THz pulses into the tunnel junction and constructed the THz-STM, achieving atomic-level spatial resolution in THz-driven current imaging and sub-picosecond (sub-ps) time resolution in autocorrelation signals during pump-probe measurements. Experimental data from various representative samples are presented to showcase the performance of the instrument, establishing it as an ideal platform for studying non-equilibrium dynamic processes at nanoscale.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The development of a low-temperature terahertz scanning tunneling microscope based on a cryogen-free scheme.\",\"authors\":\"Huaiyu Zhang, Dacheng Tian, Yang Zhan, Zijia Liu, Chen Ma, Yuwu Zhang, Jianwei Hu, Xiaoyue He, Baojie Feng, Yiqi Zhang, Lan Chen, Peng Cheng, Kehui Wu\",\"doi\":\"10.1063/5.0208689\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We have developed a cryogen-free, low-temperature terahertz scanning tunneling microscope (THz-STM). This system utilizes a continuous-flow cryogen-free cooler to achieve low temperatures of ∼25 K. Meanwhile, an ultra-small ultra-high vacuum chamber results in the reduction of the distance from sample to viewport to only 4 cm. NA = 0.6 can be achieved while placing the entire optical component, including a large parabolic mirror, outside the vacuum chamber. Thus, the convenience of optical coupling is much improved without compromising the performance of STM. Based on this, we introduced THz pulses into the tunnel junction and constructed the THz-STM, achieving atomic-level spatial resolution in THz-driven current imaging and sub-picosecond (sub-ps) time resolution in autocorrelation signals during pump-probe measurements. Experimental data from various representative samples are presented to showcase the performance of the instrument, establishing it as an ideal platform for studying non-equilibrium dynamic processes at nanoscale.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0208689\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0208689","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
摘要
我们开发了一种无低温、低温太赫兹扫描隧道显微镜(THz-STM)。同时,超小型超高真空室使样品到观察窗的距离缩短到仅 4 厘米。在将包括大型抛物面反射镜在内的整个光学元件置于真空室之外的同时,还能实现 NA = 0.6。因此,在不影响 STM 性能的前提下,大大提高了光学耦合的便利性。在此基础上,我们在隧道结中引入了太赫兹脉冲,并构建了太赫兹-STM,在太赫兹驱动电流成像中实现了原子级空间分辨率,在泵探测量中实现了自相关信号的亚皮秒(sub-ps)时间分辨率。本文介绍了各种代表性样品的实验数据,展示了该仪器的性能,使其成为研究纳米尺度非平衡动态过程的理想平台。
The development of a low-temperature terahertz scanning tunneling microscope based on a cryogen-free scheme.
We have developed a cryogen-free, low-temperature terahertz scanning tunneling microscope (THz-STM). This system utilizes a continuous-flow cryogen-free cooler to achieve low temperatures of ∼25 K. Meanwhile, an ultra-small ultra-high vacuum chamber results in the reduction of the distance from sample to viewport to only 4 cm. NA = 0.6 can be achieved while placing the entire optical component, including a large parabolic mirror, outside the vacuum chamber. Thus, the convenience of optical coupling is much improved without compromising the performance of STM. Based on this, we introduced THz pulses into the tunnel junction and constructed the THz-STM, achieving atomic-level spatial resolution in THz-driven current imaging and sub-picosecond (sub-ps) time resolution in autocorrelation signals during pump-probe measurements. Experimental data from various representative samples are presented to showcase the performance of the instrument, establishing it as an ideal platform for studying non-equilibrium dynamic processes at nanoscale.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.