Sharyn A Roodenburg, Karin Klooster, Jorine E Hartman, Konstantina Kontogianni, Judith M Brock, A Susanne Dittrich, Marlies van Dijk, T David Koster, Felix J F Herth, Dirk-Jan Slebos
{"title":"严重肺气肿患者的肺张力装置线圈治疗:前瞻性安全性和可行性试验(EFFORT)。","authors":"Sharyn A Roodenburg, Karin Klooster, Jorine E Hartman, Konstantina Kontogianni, Judith M Brock, A Susanne Dittrich, Marlies van Dijk, T David Koster, Felix J F Herth, Dirk-Jan Slebos","doi":"10.1159/000541366","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Currently, there is a lack of bronchoscopic lung volume reduction options that do not depend on fissure integrity. Endobronchial coils have been extensively studied to address this need but exhibited variable patient response and have been discontinued. Lung tension device (LTD) coils represent the next-generation coil treatment. This study aimed to evaluate safety, feasibility, and efficacy of LTD-coil treatment.</p><p><strong>Methods: </strong>Patients with advanced emphysema and hyperinflation were enrolled at two European sites. LTD-coils (Free Flow Medical, Fremont, CA, USA) were implanted in the two most destructed lobes, as determined by quantitative CT analysis, in two separate procedures. The primary endpoint was 3-month follow-up after the last treatment.</p><p><strong>Results: </strong>Fourteen patients (50% male, median age 64 years, FEV1 23%predicted, RV 249%predicted) received LTD-coil treatment: 12 received bilateral and 2 unilateral treatment. Six serious respiratory adverse events occurred within the initial 3 months posttreatment, including one device-associated death. Treatment significantly reduced in- and expiratory volume of the treated lobes (-410 [-710, -340], p = 0.004 and -650 [-730, -190] mL, p < 0.001, respectively) and improved quality of life (SGRQ total score -4.6 [-21.0, -2.6], p < 0.001). However, at a group level, no significant improvements in pulmonary function or 6-min walk distance were observed. Responder rates ranged from 18% to 54% for the different endpoints.</p><p><strong>Conclusion: </strong>This first-in-human study shows that the new LTD-coil procedure is feasible with a safety profile comparable to the previous coil treatment. While the treatment effectively reduced lobar volume and modestly improved quality of life up to 3 months' follow-up, at a group level it did not significantly enhance pulmonary function or exercise capacity.</p>","PeriodicalId":21048,"journal":{"name":"Respiration","volume":" ","pages":"58-68"},"PeriodicalIF":3.5000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11731836/pdf/","citationCount":"0","resultStr":"{\"title\":\"Lung Tensioning Device Coil Treatment in Patients with Severe Emphysema: A Prospective Safety and Feasibility Trial (EFFORT).\",\"authors\":\"Sharyn A Roodenburg, Karin Klooster, Jorine E Hartman, Konstantina Kontogianni, Judith M Brock, A Susanne Dittrich, Marlies van Dijk, T David Koster, Felix J F Herth, Dirk-Jan Slebos\",\"doi\":\"10.1159/000541366\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Currently, there is a lack of bronchoscopic lung volume reduction options that do not depend on fissure integrity. Endobronchial coils have been extensively studied to address this need but exhibited variable patient response and have been discontinued. Lung tension device (LTD) coils represent the next-generation coil treatment. This study aimed to evaluate safety, feasibility, and efficacy of LTD-coil treatment.</p><p><strong>Methods: </strong>Patients with advanced emphysema and hyperinflation were enrolled at two European sites. LTD-coils (Free Flow Medical, Fremont, CA, USA) were implanted in the two most destructed lobes, as determined by quantitative CT analysis, in two separate procedures. The primary endpoint was 3-month follow-up after the last treatment.</p><p><strong>Results: </strong>Fourteen patients (50% male, median age 64 years, FEV1 23%predicted, RV 249%predicted) received LTD-coil treatment: 12 received bilateral and 2 unilateral treatment. Six serious respiratory adverse events occurred within the initial 3 months posttreatment, including one device-associated death. Treatment significantly reduced in- and expiratory volume of the treated lobes (-410 [-710, -340], p = 0.004 and -650 [-730, -190] mL, p < 0.001, respectively) and improved quality of life (SGRQ total score -4.6 [-21.0, -2.6], p < 0.001). However, at a group level, no significant improvements in pulmonary function or 6-min walk distance were observed. Responder rates ranged from 18% to 54% for the different endpoints.</p><p><strong>Conclusion: </strong>This first-in-human study shows that the new LTD-coil procedure is feasible with a safety profile comparable to the previous coil treatment. While the treatment effectively reduced lobar volume and modestly improved quality of life up to 3 months' follow-up, at a group level it did not significantly enhance pulmonary function or exercise capacity.</p>\",\"PeriodicalId\":21048,\"journal\":{\"name\":\"Respiration\",\"volume\":\" \",\"pages\":\"58-68\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11731836/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Respiration\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000541366\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"RESPIRATORY SYSTEM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Respiration","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000541366","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/16 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
Lung Tensioning Device Coil Treatment in Patients with Severe Emphysema: A Prospective Safety and Feasibility Trial (EFFORT).
Introduction: Currently, there is a lack of bronchoscopic lung volume reduction options that do not depend on fissure integrity. Endobronchial coils have been extensively studied to address this need but exhibited variable patient response and have been discontinued. Lung tension device (LTD) coils represent the next-generation coil treatment. This study aimed to evaluate safety, feasibility, and efficacy of LTD-coil treatment.
Methods: Patients with advanced emphysema and hyperinflation were enrolled at two European sites. LTD-coils (Free Flow Medical, Fremont, CA, USA) were implanted in the two most destructed lobes, as determined by quantitative CT analysis, in two separate procedures. The primary endpoint was 3-month follow-up after the last treatment.
Results: Fourteen patients (50% male, median age 64 years, FEV1 23%predicted, RV 249%predicted) received LTD-coil treatment: 12 received bilateral and 2 unilateral treatment. Six serious respiratory adverse events occurred within the initial 3 months posttreatment, including one device-associated death. Treatment significantly reduced in- and expiratory volume of the treated lobes (-410 [-710, -340], p = 0.004 and -650 [-730, -190] mL, p < 0.001, respectively) and improved quality of life (SGRQ total score -4.6 [-21.0, -2.6], p < 0.001). However, at a group level, no significant improvements in pulmonary function or 6-min walk distance were observed. Responder rates ranged from 18% to 54% for the different endpoints.
Conclusion: This first-in-human study shows that the new LTD-coil procedure is feasible with a safety profile comparable to the previous coil treatment. While the treatment effectively reduced lobar volume and modestly improved quality of life up to 3 months' follow-up, at a group level it did not significantly enhance pulmonary function or exercise capacity.
期刊介绍:
''Respiration'' brings together the results of both clinical and experimental investigations on all aspects of the respiratory system in health and disease. Clinical improvements in the diagnosis and treatment of chest and lung diseases are covered, as are the latest findings in physiology, biochemistry, pathology, immunology and pharmacology. The journal includes classic features such as editorials that accompany original articles in clinical and basic science research, reviews and letters to the editor. Further sections are: Technical Notes, The Eye Catcher, What’s Your Diagnosis?, The Opinion Corner, New Drugs in Respiratory Medicine, New Insights from Clinical Practice and Guidelines. ''Respiration'' is the official journal of the Swiss Society for Pneumology (SGP) and also home to the European Association for Bronchology and Interventional Pulmonology (EABIP), which occupies a dedicated section on Interventional Pulmonology in the journal. This modern mix of different features and a stringent peer-review process by a dedicated editorial board make ''Respiration'' a complete guide to progress in thoracic medicine.