{"title":"使用 Melinex 薄膜将组织切片平铺包埋在 LR White 中。","authors":"C J von Ruhland","doi":"10.1111/jmi.13359","DOIUrl":null,"url":null,"abstract":"<p><p>Tissue slices can undergo distortions during processing into resin for light and electron microscopy as a result of differential shrinkage of the various tissue components, and this may necessitate removal of a considerable amount of material from the final resin-embedded tissue block to ensure production of complete sections of the sample. To mitigate this problem, a number of techniques have been devised that ensure the sample is held flat during the final curing/polymerisation of the resin. For embedding in acrylic resins, oxygen must be excluded as it inhibits polymerisation, and methods devised for epoxy resin embedding are generally unsuitable. The method describes the preparation and use of air-tight flat-embedding chambers prepared from Melinex film and provides an inexpensive, technically simpler, and versatile alternative to chambers formed from either Thermanox coverslips or Aclar films that have previously been advocated for such purposes. Lay description: Tissue slices can undergo distortions during processing into resin for light and electron microscopy as a result of differential shrinkage of the various tissue components. Such distortions may necessitate removal of a considerable amount of material to ensure production of complete sections of the sample. For embedding in acrylic resins, oxygen must be excluded as it inhibits polymerisation, and methods devised for epoxy resin flat-embedding are generally unsuitable. Air-tight flat-embedding chambers prepared from either Thermanox coverslips, or a combination of PTFE-coated glass slides, polycarbonate film gaskets, and Aclar film have been advocated for such purposes. Thermanox coverslips are expensive and limited in size to 22 mm × 60 mm, and the alternative method is technically complicated. Melinex film is commercially available as 210 mm × 297 mm sheets and is approximately 1/20th the price of Thermanox and less than half the price of Aclar film. The method describes the preparation and use of embedding chambers made from Melinex film, glass slides and double-sided adhesive tape as a technically simpler, inexpensive and versatile alternative to both Thermanox coverslips and the Aclar film method.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Use of Melinex film for flat embedding tissue sections in LR White.\",\"authors\":\"C J von Ruhland\",\"doi\":\"10.1111/jmi.13359\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Tissue slices can undergo distortions during processing into resin for light and electron microscopy as a result of differential shrinkage of the various tissue components, and this may necessitate removal of a considerable amount of material from the final resin-embedded tissue block to ensure production of complete sections of the sample. To mitigate this problem, a number of techniques have been devised that ensure the sample is held flat during the final curing/polymerisation of the resin. For embedding in acrylic resins, oxygen must be excluded as it inhibits polymerisation, and methods devised for epoxy resin embedding are generally unsuitable. The method describes the preparation and use of air-tight flat-embedding chambers prepared from Melinex film and provides an inexpensive, technically simpler, and versatile alternative to chambers formed from either Thermanox coverslips or Aclar films that have previously been advocated for such purposes. Lay description: Tissue slices can undergo distortions during processing into resin for light and electron microscopy as a result of differential shrinkage of the various tissue components. Such distortions may necessitate removal of a considerable amount of material to ensure production of complete sections of the sample. For embedding in acrylic resins, oxygen must be excluded as it inhibits polymerisation, and methods devised for epoxy resin flat-embedding are generally unsuitable. Air-tight flat-embedding chambers prepared from either Thermanox coverslips, or a combination of PTFE-coated glass slides, polycarbonate film gaskets, and Aclar film have been advocated for such purposes. Thermanox coverslips are expensive and limited in size to 22 mm × 60 mm, and the alternative method is technically complicated. Melinex film is commercially available as 210 mm × 297 mm sheets and is approximately 1/20th the price of Thermanox and less than half the price of Aclar film. The method describes the preparation and use of embedding chambers made from Melinex film, glass slides and double-sided adhesive tape as a technically simpler, inexpensive and versatile alternative to both Thermanox coverslips and the Aclar film method.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-09-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1111/jmi.13359\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/jmi.13359","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Use of Melinex film for flat embedding tissue sections in LR White.
Tissue slices can undergo distortions during processing into resin for light and electron microscopy as a result of differential shrinkage of the various tissue components, and this may necessitate removal of a considerable amount of material from the final resin-embedded tissue block to ensure production of complete sections of the sample. To mitigate this problem, a number of techniques have been devised that ensure the sample is held flat during the final curing/polymerisation of the resin. For embedding in acrylic resins, oxygen must be excluded as it inhibits polymerisation, and methods devised for epoxy resin embedding are generally unsuitable. The method describes the preparation and use of air-tight flat-embedding chambers prepared from Melinex film and provides an inexpensive, technically simpler, and versatile alternative to chambers formed from either Thermanox coverslips or Aclar films that have previously been advocated for such purposes. Lay description: Tissue slices can undergo distortions during processing into resin for light and electron microscopy as a result of differential shrinkage of the various tissue components. Such distortions may necessitate removal of a considerable amount of material to ensure production of complete sections of the sample. For embedding in acrylic resins, oxygen must be excluded as it inhibits polymerisation, and methods devised for epoxy resin flat-embedding are generally unsuitable. Air-tight flat-embedding chambers prepared from either Thermanox coverslips, or a combination of PTFE-coated glass slides, polycarbonate film gaskets, and Aclar film have been advocated for such purposes. Thermanox coverslips are expensive and limited in size to 22 mm × 60 mm, and the alternative method is technically complicated. Melinex film is commercially available as 210 mm × 297 mm sheets and is approximately 1/20th the price of Thermanox and less than half the price of Aclar film. The method describes the preparation and use of embedding chambers made from Melinex film, glass slides and double-sided adhesive tape as a technically simpler, inexpensive and versatile alternative to both Thermanox coverslips and the Aclar film method.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.