{"title":"多部位胎儿脑磁共振成像的部位效应:早期大脑发育的形态学启示。","authors":"Xinyi Xu, Cong Sun, Hong Yu, Guohui Yan, Qingqing Zhu, Xianglei Kong, Yibin Pan, Haoan Xu, Tianshu Zheng, Chi Zhou, Yutian Wang, Jiaxin Xiao, Ruike Chen, Mingyang Li, Songying Zhang, Hongjie Hu, Yu Zou, Jingshi Wang, Guangbin Wang, Dan Wu","doi":"10.1007/s00330-024-11084-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate multisite effects on fetal brain MRI. Specifically, to identify crucial acquisition factors affecting fetal brain structural measurements and developmental patterns, while assessing the effectiveness of existing harmonization methods in mitigating site effects.</p><p><strong>Materials and methods: </strong>Between May 2017 and March 2022, T2-weighted fast spin-echo sequences in-utero MRI were performed on healthy fetuses from retrospectively recruited pregnant volunteers on four different scanners at four sites. A generalized additive model (GAM) was used to quantitatively assess site effects, including field strength (FS), manufacturer (M), in-plane resolution (R), and slice thickness (ST), on subcortical volume and cortical morphological measurements, including cortical thickness, curvature, and sulcal depth. Growth models were selected to elucidate the developmental trajectories of these morphological measurements. Welch's test was performed to evaluate the influence of site effects on developmental trajectories. The comBat-GAM harmonization method was applied to mitigate site-related biases.</p><p><strong>Results: </strong>The final analytic sample consisted of 340 MRI scans from 218 fetuses (mean GA, 30.1 weeks ± 4.4 [range, 21.7-40 weeks]). GAM results showed that lower FS and lower spatial resolution led to overestimations in selected brain regions of subcortical volumes and cortical morphological measurements. Only the peak cortical thickness in developmental trajectories was significantly influenced by the effects of FS and R. Notably, ComBat-GAM harmonization effectively removed site effects while preserving developmental patterns.</p><p><strong>Conclusion: </strong>Our findings pinpointed the key acquisition factors in in-utero fetal brain MRI and underscored the necessity of data harmonization when pooling multisite data for fetal brain morphology investigations.</p><p><strong>Key points: </strong>Question How do specific site MRI acquisition factors affect fetal brain imaging? Finding Lower FS and spatial resolution overestimated subcortical volumes and cortical measurements. Cortical thickness in developmental trajectories was influenced by FS and in-plane resolution. Clinical relevance This study provides important guidelines for the fetal MRI community when scanning fetal brains and underscores the necessity of data harmonization of cross-center fetal studies.</p>","PeriodicalId":12076,"journal":{"name":"European Radiology","volume":" ","pages":"1830-1842"},"PeriodicalIF":4.7000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Site effects in multisite fetal brain MRI: morphological insights into early brain development.\",\"authors\":\"Xinyi Xu, Cong Sun, Hong Yu, Guohui Yan, Qingqing Zhu, Xianglei Kong, Yibin Pan, Haoan Xu, Tianshu Zheng, Chi Zhou, Yutian Wang, Jiaxin Xiao, Ruike Chen, Mingyang Li, Songying Zhang, Hongjie Hu, Yu Zou, Jingshi Wang, Guangbin Wang, Dan Wu\",\"doi\":\"10.1007/s00330-024-11084-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To evaluate multisite effects on fetal brain MRI. Specifically, to identify crucial acquisition factors affecting fetal brain structural measurements and developmental patterns, while assessing the effectiveness of existing harmonization methods in mitigating site effects.</p><p><strong>Materials and methods: </strong>Between May 2017 and March 2022, T2-weighted fast spin-echo sequences in-utero MRI were performed on healthy fetuses from retrospectively recruited pregnant volunteers on four different scanners at four sites. A generalized additive model (GAM) was used to quantitatively assess site effects, including field strength (FS), manufacturer (M), in-plane resolution (R), and slice thickness (ST), on subcortical volume and cortical morphological measurements, including cortical thickness, curvature, and sulcal depth. Growth models were selected to elucidate the developmental trajectories of these morphological measurements. Welch's test was performed to evaluate the influence of site effects on developmental trajectories. The comBat-GAM harmonization method was applied to mitigate site-related biases.</p><p><strong>Results: </strong>The final analytic sample consisted of 340 MRI scans from 218 fetuses (mean GA, 30.1 weeks ± 4.4 [range, 21.7-40 weeks]). GAM results showed that lower FS and lower spatial resolution led to overestimations in selected brain regions of subcortical volumes and cortical morphological measurements. Only the peak cortical thickness in developmental trajectories was significantly influenced by the effects of FS and R. Notably, ComBat-GAM harmonization effectively removed site effects while preserving developmental patterns.</p><p><strong>Conclusion: </strong>Our findings pinpointed the key acquisition factors in in-utero fetal brain MRI and underscored the necessity of data harmonization when pooling multisite data for fetal brain morphology investigations.</p><p><strong>Key points: </strong>Question How do specific site MRI acquisition factors affect fetal brain imaging? Finding Lower FS and spatial resolution overestimated subcortical volumes and cortical measurements. Cortical thickness in developmental trajectories was influenced by FS and in-plane resolution. Clinical relevance This study provides important guidelines for the fetal MRI community when scanning fetal brains and underscores the necessity of data harmonization of cross-center fetal studies.</p>\",\"PeriodicalId\":12076,\"journal\":{\"name\":\"European Radiology\",\"volume\":\" \",\"pages\":\"1830-1842\"},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00330-024-11084-w\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00330-024-11084-w","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/19 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Site effects in multisite fetal brain MRI: morphological insights into early brain development.
Objective: To evaluate multisite effects on fetal brain MRI. Specifically, to identify crucial acquisition factors affecting fetal brain structural measurements and developmental patterns, while assessing the effectiveness of existing harmonization methods in mitigating site effects.
Materials and methods: Between May 2017 and March 2022, T2-weighted fast spin-echo sequences in-utero MRI were performed on healthy fetuses from retrospectively recruited pregnant volunteers on four different scanners at four sites. A generalized additive model (GAM) was used to quantitatively assess site effects, including field strength (FS), manufacturer (M), in-plane resolution (R), and slice thickness (ST), on subcortical volume and cortical morphological measurements, including cortical thickness, curvature, and sulcal depth. Growth models were selected to elucidate the developmental trajectories of these morphological measurements. Welch's test was performed to evaluate the influence of site effects on developmental trajectories. The comBat-GAM harmonization method was applied to mitigate site-related biases.
Results: The final analytic sample consisted of 340 MRI scans from 218 fetuses (mean GA, 30.1 weeks ± 4.4 [range, 21.7-40 weeks]). GAM results showed that lower FS and lower spatial resolution led to overestimations in selected brain regions of subcortical volumes and cortical morphological measurements. Only the peak cortical thickness in developmental trajectories was significantly influenced by the effects of FS and R. Notably, ComBat-GAM harmonization effectively removed site effects while preserving developmental patterns.
Conclusion: Our findings pinpointed the key acquisition factors in in-utero fetal brain MRI and underscored the necessity of data harmonization when pooling multisite data for fetal brain morphology investigations.
Key points: Question How do specific site MRI acquisition factors affect fetal brain imaging? Finding Lower FS and spatial resolution overestimated subcortical volumes and cortical measurements. Cortical thickness in developmental trajectories was influenced by FS and in-plane resolution. Clinical relevance This study provides important guidelines for the fetal MRI community when scanning fetal brains and underscores the necessity of data harmonization of cross-center fetal studies.
期刊介绍:
European Radiology (ER) continuously updates scientific knowledge in radiology by publication of strong original articles and state-of-the-art reviews written by leading radiologists. A well balanced combination of review articles, original papers, short communications from European radiological congresses and information on society matters makes ER an indispensable source for current information in this field.
This is the Journal of the European Society of Radiology, and the official journal of a number of societies.
From 2004-2008 supplements to European Radiology were published under its companion, European Radiology Supplements, ISSN 1613-3749.