Horaţiu Moldovan, Maria Sabina Safta, Liliana Mirea, Aida Badea, Elena Nechifor, Andrada Guţă, Lucian Dorobanţu, Cristian Voica, Mircea Robu, Daniela Gheorghiţă, Mihaela Crăciun, Alexandru Zăman, Raluca Ciomag
{"title":"一名 60 岁男性冠状动脉起源解剖变异患者的改良 Cabrol 技术病例报告。","authors":"Horaţiu Moldovan, Maria Sabina Safta, Liliana Mirea, Aida Badea, Elena Nechifor, Andrada Guţă, Lucian Dorobanţu, Cristian Voica, Mircea Robu, Daniela Gheorghiţă, Mihaela Crăciun, Alexandru Zăman, Raluca Ciomag","doi":"10.21614/chirurgia.2967","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction:</b> Reconstruction surgery of the proximal aorta in most cases involves the use of an aortic conduit, followed by reimplantation of the coronary ostia. Although uncommon, the origin of the coronary arteries in certain anatomical variants poses additional difficulties when performing surgery on the aortic root and requires a different treatment rationale. Case report: We hereby present the case of a 60-year-old patient with multiple cardiovascular risk factors (smoking, arterial hypertension and dyslipidemia), suffering from severe degenerative stenosis of a bicuspid aortic valve, associated with ascending aorta aneurysm and a significant extrinsic stenosis of the left coronary artery caused by the aneurysm. The patient presented with severe degenerative bicuspid aortic valve stenosis associated with ascending aorta aneurysm and a significant extrinsic stenosis of the left coronary artery caused by the aneurysm. Following the preoperative assessment, it was decided that the best course of action was to perform surgery on the aortic valve and ascending aorta. During the surgery, the origin of the right and left coronary ostia were found at the level of the left coronary cusp, both forming a common coronary button. Due to this particular anatomical variant, it was decided to reimplant them as a common button onto the main conduit by means of an interposed No.10 PTFE (Polytetrafluoroethylene) vascular prosthesis. Conclusion: A rare case of aortic root surgery associated with coronary ostia origin variant \"shotgun barrel\", which required a different method of reimplantation: modified Cabrol technique.</p>","PeriodicalId":10171,"journal":{"name":"Chirurgia","volume":"119 4","pages":"445-451"},"PeriodicalIF":0.8000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Case Report of Modified Cabrol Technique in a 60-Year-Old Male with Coronary Origin Anatomical Variant.\",\"authors\":\"Horaţiu Moldovan, Maria Sabina Safta, Liliana Mirea, Aida Badea, Elena Nechifor, Andrada Guţă, Lucian Dorobanţu, Cristian Voica, Mircea Robu, Daniela Gheorghiţă, Mihaela Crăciun, Alexandru Zăman, Raluca Ciomag\",\"doi\":\"10.21614/chirurgia.2967\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Introduction:</b> Reconstruction surgery of the proximal aorta in most cases involves the use of an aortic conduit, followed by reimplantation of the coronary ostia. Although uncommon, the origin of the coronary arteries in certain anatomical variants poses additional difficulties when performing surgery on the aortic root and requires a different treatment rationale. Case report: We hereby present the case of a 60-year-old patient with multiple cardiovascular risk factors (smoking, arterial hypertension and dyslipidemia), suffering from severe degenerative stenosis of a bicuspid aortic valve, associated with ascending aorta aneurysm and a significant extrinsic stenosis of the left coronary artery caused by the aneurysm. The patient presented with severe degenerative bicuspid aortic valve stenosis associated with ascending aorta aneurysm and a significant extrinsic stenosis of the left coronary artery caused by the aneurysm. Following the preoperative assessment, it was decided that the best course of action was to perform surgery on the aortic valve and ascending aorta. During the surgery, the origin of the right and left coronary ostia were found at the level of the left coronary cusp, both forming a common coronary button. Due to this particular anatomical variant, it was decided to reimplant them as a common button onto the main conduit by means of an interposed No.10 PTFE (Polytetrafluoroethylene) vascular prosthesis. Conclusion: A rare case of aortic root surgery associated with coronary ostia origin variant \\\"shotgun barrel\\\", which required a different method of reimplantation: modified Cabrol technique.</p>\",\"PeriodicalId\":10171,\"journal\":{\"name\":\"Chirurgia\",\"volume\":\"119 4\",\"pages\":\"445-451\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chirurgia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21614/chirurgia.2967\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chirurgia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21614/chirurgia.2967","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
A Case Report of Modified Cabrol Technique in a 60-Year-Old Male with Coronary Origin Anatomical Variant.
Introduction: Reconstruction surgery of the proximal aorta in most cases involves the use of an aortic conduit, followed by reimplantation of the coronary ostia. Although uncommon, the origin of the coronary arteries in certain anatomical variants poses additional difficulties when performing surgery on the aortic root and requires a different treatment rationale. Case report: We hereby present the case of a 60-year-old patient with multiple cardiovascular risk factors (smoking, arterial hypertension and dyslipidemia), suffering from severe degenerative stenosis of a bicuspid aortic valve, associated with ascending aorta aneurysm and a significant extrinsic stenosis of the left coronary artery caused by the aneurysm. The patient presented with severe degenerative bicuspid aortic valve stenosis associated with ascending aorta aneurysm and a significant extrinsic stenosis of the left coronary artery caused by the aneurysm. Following the preoperative assessment, it was decided that the best course of action was to perform surgery on the aortic valve and ascending aorta. During the surgery, the origin of the right and left coronary ostia were found at the level of the left coronary cusp, both forming a common coronary button. Due to this particular anatomical variant, it was decided to reimplant them as a common button onto the main conduit by means of an interposed No.10 PTFE (Polytetrafluoroethylene) vascular prosthesis. Conclusion: A rare case of aortic root surgery associated with coronary ostia origin variant "shotgun barrel", which required a different method of reimplantation: modified Cabrol technique.
期刊介绍:
Chirurgia is a bimonthly journal. In Chirurgia, original papers in the area of general surgery which neither
appeared, nor were sent for publication in other periodicals, can be published. You can send original articles,
new surgical techniques, or comprehensive general reports on surgical topics, clinical case presentations and,
depending on publication space, - reviews of some articles of general interest to surgeons from other publications.
Chirurgia is also a place for sharing information about the activity of various branches of the Romanian Society of
Surgery, information on Congresses and Symposiums organized by the Romanian Society of Surgery and
participation notes in other scientific meetings.
Letters to the editor: Letters commenting on papers published in Chirurgia are welcomed. They should contain
substantive ideas and commentaries supported by appropriate data, and should not exceed 2 pages. Please
submit these letters to the editor through our online system.