流变仪能否用于测定可可基馅奶油的烘焙稳定性

IF 5.3 2区 农林科学 Q1 ENGINEERING, CHEMICAL
Burcu Utku Aktar , Arzu Karakaş İshak , Duygu Ozmen , Halide Ezgi Tuna Ağırbaş , Ozer Atıl , Omer Said Toker
{"title":"流变仪能否用于测定可可基馅奶油的烘焙稳定性","authors":"Burcu Utku Aktar ,&nbsp;Arzu Karakaş İshak ,&nbsp;Duygu Ozmen ,&nbsp;Halide Ezgi Tuna Ağırbaş ,&nbsp;Ozer Atıl ,&nbsp;Omer Said Toker","doi":"10.1016/j.jfoodeng.2024.112320","DOIUrl":null,"url":null,"abstract":"<div><p>Bake stable filling creams are important for some products such as biscuits, cakes, cookies, etc. In the present study, a rheometer-based method for determining the baking stability of the cream fillings was developed considering the consistency and fluidity of the fillings after baking. For this aim, the heating and cooling process was simulated depending on the temperature of the filling reached during the baking process of cookies. Three bake-stable and three bake-unstable filling creams were obtained from the market. Rheological, textural, and baking stability analysis were performed on the samples. Change in the apparent viscosity values of the samples was observed at temperature values from 20 °C to 105 °C and from 105 °C to 30 °C using rheometer. The percentage of viscosity change at 30 °C before and after the heating process was calculated. This value for stable samples was 67%, 73% and 9%. Fluctuation observation during the measurement is also important for stability. Unstable fillings have many fluctuations in the temperature versus apparent viscosity curve as their viscosity change value was lower. The absence of fluctuations on the temperature versus viscosity graph indicates the stability of the filling creams. The findings of the study indicated that a rheometer can be used as an effective tool for determining the baking stability of the creams with minimal effort, labor, sample requirement, and time.</p></div>","PeriodicalId":359,"journal":{"name":"Journal of Food Engineering","volume":"387 ","pages":"Article 112320"},"PeriodicalIF":5.3000,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Can rheometer be used for determination of baking stability of cocoa based filling creams\",\"authors\":\"Burcu Utku Aktar ,&nbsp;Arzu Karakaş İshak ,&nbsp;Duygu Ozmen ,&nbsp;Halide Ezgi Tuna Ağırbaş ,&nbsp;Ozer Atıl ,&nbsp;Omer Said Toker\",\"doi\":\"10.1016/j.jfoodeng.2024.112320\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Bake stable filling creams are important for some products such as biscuits, cakes, cookies, etc. In the present study, a rheometer-based method for determining the baking stability of the cream fillings was developed considering the consistency and fluidity of the fillings after baking. For this aim, the heating and cooling process was simulated depending on the temperature of the filling reached during the baking process of cookies. Three bake-stable and three bake-unstable filling creams were obtained from the market. Rheological, textural, and baking stability analysis were performed on the samples. Change in the apparent viscosity values of the samples was observed at temperature values from 20 °C to 105 °C and from 105 °C to 30 °C using rheometer. The percentage of viscosity change at 30 °C before and after the heating process was calculated. This value for stable samples was 67%, 73% and 9%. Fluctuation observation during the measurement is also important for stability. Unstable fillings have many fluctuations in the temperature versus apparent viscosity curve as their viscosity change value was lower. The absence of fluctuations on the temperature versus viscosity graph indicates the stability of the filling creams. The findings of the study indicated that a rheometer can be used as an effective tool for determining the baking stability of the creams with minimal effort, labor, sample requirement, and time.</p></div>\",\"PeriodicalId\":359,\"journal\":{\"name\":\"Journal of Food Engineering\",\"volume\":\"387 \",\"pages\":\"Article 112320\"},\"PeriodicalIF\":5.3000,\"publicationDate\":\"2024-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Food Engineering\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0260877424003868\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, CHEMICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Food Engineering","FirstCategoryId":"97","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0260877424003868","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0

摘要

对于饼干、蛋糕、曲奇等一些产品来说,烘焙稳定的奶油馅非常重要。在本研究中,考虑到烘焙后馅料的稠度和流动性,开发了一种基于流变仪的方法来确定奶油馅料的烘焙稳定性。为此,根据饼干烘焙过程中馅料达到的温度,模拟了加热和冷却过程。从市场上获得了三种烘焙稳定型和三种烘焙不稳定型馅料奶油。对样品进行了流变学、质地和烘焙稳定性分析。使用流变仪观察了样品在 20 °C 至 105 °C 和 105 °C 至 30 °C 温度值下表观粘度值的变化。计算了加热过程前后 30 °C 下粘度变化的百分比。稳定样品的这一数值分别为 67%、73% 和 9%。测量过程中的波动观察对稳定性也很重要。不稳定的填料在温度与表观粘度曲线上会有很多波动,因为它们的粘度变化值较低。温度与表观粘度曲线图上没有波动说明填充膏具有稳定性。研究结果表明,流变仪可以作为一种有效的工具,以最小的工作量、人力、样品要求和时间来确定奶油的烘焙稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Can rheometer be used for determination of baking stability of cocoa based filling creams

Bake stable filling creams are important for some products such as biscuits, cakes, cookies, etc. In the present study, a rheometer-based method for determining the baking stability of the cream fillings was developed considering the consistency and fluidity of the fillings after baking. For this aim, the heating and cooling process was simulated depending on the temperature of the filling reached during the baking process of cookies. Three bake-stable and three bake-unstable filling creams were obtained from the market. Rheological, textural, and baking stability analysis were performed on the samples. Change in the apparent viscosity values of the samples was observed at temperature values from 20 °C to 105 °C and from 105 °C to 30 °C using rheometer. The percentage of viscosity change at 30 °C before and after the heating process was calculated. This value for stable samples was 67%, 73% and 9%. Fluctuation observation during the measurement is also important for stability. Unstable fillings have many fluctuations in the temperature versus apparent viscosity curve as their viscosity change value was lower. The absence of fluctuations on the temperature versus viscosity graph indicates the stability of the filling creams. The findings of the study indicated that a rheometer can be used as an effective tool for determining the baking stability of the creams with minimal effort, labor, sample requirement, and time.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Food Engineering
Journal of Food Engineering 工程技术-工程:化工
CiteScore
11.80
自引率
5.50%
发文量
275
审稿时长
24 days
期刊介绍: The journal publishes original research and review papers on any subject at the interface between food and engineering, particularly those of relevance to industry, including: Engineering properties of foods, food physics and physical chemistry; processing, measurement, control, packaging, storage and distribution; engineering aspects of the design and production of novel foods and of food service and catering; design and operation of food processes, plant and equipment; economics of food engineering, including the economics of alternative processes. Accounts of food engineering achievements are of particular value.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信