低压电容耦合射频放电的统一全局模型及电压和电流传感器

IF 2.3 4区 物理与天体物理 Q3 PHYSICS, APPLIED
Inho Seong, Sijun Kim, Woobeen Lee, Youngseok Lee, Chulhee Cho, Wonnyoung Jeong, Minsu Choi, Byeongyeop Choi, Huichan Seo, Sangheon Song and Shinjae You
{"title":"低压电容耦合射频放电的统一全局模型及电压和电流传感器","authors":"Inho Seong, Sijun Kim, Woobeen Lee, Youngseok Lee, Chulhee Cho, Wonnyoung Jeong, Minsu Choi, Byeongyeop Choi, Huichan Seo, Sangheon Song and Shinjae You","doi":"10.35848/1882-0786/ad7667","DOIUrl":null,"url":null,"abstract":"A global model (GM) assumes ion energy ( ) on the electrode equals the time-averaged sheath voltage ( ). However, using particle-in-cell simulation, we found that differs from We propose a unified global model (UGM) that calculates and collisional energy losses of ions by employing plasma circuit and sheath models, accompanied by a voltage and current sensor. We compared the results of the UGM with the experimental measurements and the results revealed that UGM is closer to the experiment than GM. UGM shows a linear relationship with the experiment, indicating that the UGM is applicable for plasma monitoring.","PeriodicalId":8093,"journal":{"name":"Applied Physics Express","volume":"1 1","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A unified global model accompanied with a voltage and current sensor for low-pressure capacitively coupled RF discharge\",\"authors\":\"Inho Seong, Sijun Kim, Woobeen Lee, Youngseok Lee, Chulhee Cho, Wonnyoung Jeong, Minsu Choi, Byeongyeop Choi, Huichan Seo, Sangheon Song and Shinjae You\",\"doi\":\"10.35848/1882-0786/ad7667\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A global model (GM) assumes ion energy ( ) on the electrode equals the time-averaged sheath voltage ( ). However, using particle-in-cell simulation, we found that differs from We propose a unified global model (UGM) that calculates and collisional energy losses of ions by employing plasma circuit and sheath models, accompanied by a voltage and current sensor. We compared the results of the UGM with the experimental measurements and the results revealed that UGM is closer to the experiment than GM. UGM shows a linear relationship with the experiment, indicating that the UGM is applicable for plasma monitoring.\",\"PeriodicalId\":8093,\"journal\":{\"name\":\"Applied Physics Express\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Physics Express\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.35848/1882-0786/ad7667\",\"RegionNum\":4,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"PHYSICS, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Physics Express","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.35848/1882-0786/ad7667","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
引用次数: 0

摘要

全局模型(GM)假定电极上的离子能量( )等于时间平均鞘电压( )。我们提出了一种统一的全局模型(UGM),通过等离子回路和鞘模型以及电压和电流传感器来计算离子的能量损失和碰撞能量损失。我们将 UGM 的结果与实验测量结果进行了比较,结果表明 UGM 比 GM 更接近实验结果。UGM 与实验结果呈线性关系,表明 UGM 适用于等离子体监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A unified global model accompanied with a voltage and current sensor for low-pressure capacitively coupled RF discharge
A global model (GM) assumes ion energy ( ) on the electrode equals the time-averaged sheath voltage ( ). However, using particle-in-cell simulation, we found that differs from We propose a unified global model (UGM) that calculates and collisional energy losses of ions by employing plasma circuit and sheath models, accompanied by a voltage and current sensor. We compared the results of the UGM with the experimental measurements and the results revealed that UGM is closer to the experiment than GM. UGM shows a linear relationship with the experiment, indicating that the UGM is applicable for plasma monitoring.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applied Physics Express
Applied Physics Express 物理-物理:应用
CiteScore
4.80
自引率
8.70%
发文量
310
审稿时长
1.2 months
期刊介绍: Applied Physics Express (APEX) is a letters journal devoted solely to rapid dissemination of up-to-date and concise reports on new findings in applied physics. The motto of APEX is high scientific quality and prompt publication. APEX is a sister journal of the Japanese Journal of Applied Physics (JJAP) and is published by IOP Publishing Ltd on behalf of the Japan Society of Applied Physics (JSAP).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信