有内耳畸形和无内耳畸形人工耳蜗用户的 eCAP 类型有何不同:振幅增长功能、激励扩散、折返恢复功能

IF 1.9 3区 医学 Q2 OTORHINOLARYNGOLOGY
Betul Cicek Cinar, Merve Özses
{"title":"有内耳畸形和无内耳畸形人工耳蜗用户的 eCAP 类型有何不同:振幅增长功能、激励扩散、折返恢复功能","authors":"Betul Cicek Cinar, Merve Özses","doi":"10.1007/s00405-024-08971-9","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Objectives</h3><p>Inner ear malformations (IEMs) may result in differences in outcomes of cochlear implant user. These differences could be observed in both behavioral and objective tests. eCAP is the most common used objective test in cochlear implants and have different presence rate in cochlear implant users with and without IEMs. This study aims to evaluate eCAP results from CI user with and without IEMs through different recoding methods; amplitude growth function, spreads of excitation and refractory recovery.</p><h3 data-test=\"abstract-sub-heading\">Methods</h3><p>There were 42 CI users (20 IEM&amp;22 normal) above five-years old and with at least one year experience. Three different eCAP measurement was conducted at several intracochlear electrodes. Presence rate, threshold levels and amplitude were compared between groups.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>For Amplitude growth function measurement, when the percentage of detected eCAP thresholds was analyzed between groups, there was a significant difference only for basal electrode and no significant difference for apical and middle electrodes. Similarly, the presence rate of RecF-eCAP for both groups were in a downward trend from apical to basal. However, there was no significant difference in AGF-eCAP and RecF-eCAP amplitudes between groups for the cochlea’s apical, middle and basal region. Although the presence rate of SOE-eCAP was lower for IEM group, there was no significant difference in ECAP amplitudes for all maskers.</p><h3 data-test=\"abstract-sub-heading\">Conclusions</h3><p>It could be inferred that even though the observable eCAP rate differed between these two groups when the observable eCAP was recorded, the IEM group produced eCAP with similar amplitudes to normal cochlea group.</p>","PeriodicalId":11952,"journal":{"name":"European Archives of Oto-Rhino-Laryngology","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"How differ eCAP types in cochlear implants users with and without inner ear malformations: amplitude growth function, spread of excitation, refractory recovery function\",\"authors\":\"Betul Cicek Cinar, Merve Özses\",\"doi\":\"10.1007/s00405-024-08971-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<h3 data-test=\\\"abstract-sub-heading\\\">Objectives</h3><p>Inner ear malformations (IEMs) may result in differences in outcomes of cochlear implant user. These differences could be observed in both behavioral and objective tests. eCAP is the most common used objective test in cochlear implants and have different presence rate in cochlear implant users with and without IEMs. This study aims to evaluate eCAP results from CI user with and without IEMs through different recoding methods; amplitude growth function, spreads of excitation and refractory recovery.</p><h3 data-test=\\\"abstract-sub-heading\\\">Methods</h3><p>There were 42 CI users (20 IEM&amp;22 normal) above five-years old and with at least one year experience. Three different eCAP measurement was conducted at several intracochlear electrodes. Presence rate, threshold levels and amplitude were compared between groups.</p><h3 data-test=\\\"abstract-sub-heading\\\">Results</h3><p>For Amplitude growth function measurement, when the percentage of detected eCAP thresholds was analyzed between groups, there was a significant difference only for basal electrode and no significant difference for apical and middle electrodes. Similarly, the presence rate of RecF-eCAP for both groups were in a downward trend from apical to basal. However, there was no significant difference in AGF-eCAP and RecF-eCAP amplitudes between groups for the cochlea’s apical, middle and basal region. Although the presence rate of SOE-eCAP was lower for IEM group, there was no significant difference in ECAP amplitudes for all maskers.</p><h3 data-test=\\\"abstract-sub-heading\\\">Conclusions</h3><p>It could be inferred that even though the observable eCAP rate differed between these two groups when the observable eCAP was recorded, the IEM group produced eCAP with similar amplitudes to normal cochlea group.</p>\",\"PeriodicalId\":11952,\"journal\":{\"name\":\"European Archives of Oto-Rhino-Laryngology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-09-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Archives of Oto-Rhino-Laryngology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00405-024-08971-9\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Archives of Oto-Rhino-Laryngology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00405-024-08971-9","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的内耳畸形(IEMs)可能会导致人工耳蜗植入者的效果不同。eCAP 是人工耳蜗植入中最常用的客观测试,在有内耳畸形和无内耳畸形的人工耳蜗植入者中有不同的存在率。本研究旨在通过不同的重新编码方法、振幅增长函数、激励扩散和折返恢复来评估使用和未使用 IEM 的人工耳蜗用户的 eCAP 结果。在多个耳蜗内电极上进行了三种不同的 eCAP 测量。结果在振幅增长功能测量中,当分析组间检测到的 eCAP 阈值百分比时,只有基底电极有显著差异,心尖电极和中间电极无显著差异。同样,两组的 RecF-eCAP 出现率从心尖到心底均呈下降趋势。然而,在耳蜗尖部、中部和基底区域,各组之间的 AGF-eCAP 和 RecF-eCAP 振幅没有明显差异。虽然 IEM 组的 SOE-eCAP 出现率较低,但所有掩蔽者的 ECAP 振幅均无显著差异。结论可以推断,尽管在记录可观察到的 eCAP 时,两组之间的可观察到的 eCAP 出现率存在差异,但 IEM 组产生的 eCAP 振幅与正常耳蜗组相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

How differ eCAP types in cochlear implants users with and without inner ear malformations: amplitude growth function, spread of excitation, refractory recovery function

How differ eCAP types in cochlear implants users with and without inner ear malformations: amplitude growth function, spread of excitation, refractory recovery function

Objectives

Inner ear malformations (IEMs) may result in differences in outcomes of cochlear implant user. These differences could be observed in both behavioral and objective tests. eCAP is the most common used objective test in cochlear implants and have different presence rate in cochlear implant users with and without IEMs. This study aims to evaluate eCAP results from CI user with and without IEMs through different recoding methods; amplitude growth function, spreads of excitation and refractory recovery.

Methods

There were 42 CI users (20 IEM&22 normal) above five-years old and with at least one year experience. Three different eCAP measurement was conducted at several intracochlear electrodes. Presence rate, threshold levels and amplitude were compared between groups.

Results

For Amplitude growth function measurement, when the percentage of detected eCAP thresholds was analyzed between groups, there was a significant difference only for basal electrode and no significant difference for apical and middle electrodes. Similarly, the presence rate of RecF-eCAP for both groups were in a downward trend from apical to basal. However, there was no significant difference in AGF-eCAP and RecF-eCAP amplitudes between groups for the cochlea’s apical, middle and basal region. Although the presence rate of SOE-eCAP was lower for IEM group, there was no significant difference in ECAP amplitudes for all maskers.

Conclusions

It could be inferred that even though the observable eCAP rate differed between these two groups when the observable eCAP was recorded, the IEM group produced eCAP with similar amplitudes to normal cochlea group.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.30
自引率
7.70%
发文量
537
审稿时长
2-4 weeks
期刊介绍: Official Journal of European Union of Medical Specialists – ORL Section and Board Official Journal of Confederation of European Oto-Rhino-Laryngology Head and Neck Surgery "European Archives of Oto-Rhino-Laryngology" publishes original clinical reports and clinically relevant experimental studies, as well as short communications presenting new results of special interest. With peer review by a respected international editorial board and prompt English-language publication, the journal provides rapid dissemination of information by authors from around the world. This particular feature makes it the journal of choice for readers who want to be informed about the continuing state of the art concerning basic sciences and the diagnosis and management of diseases of the head and neck on an international level. European Archives of Oto-Rhino-Laryngology was founded in 1864 as "Archiv für Ohrenheilkunde" by A. von Tröltsch, A. Politzer and H. Schwartze.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信