C. H. Ortiz, J. M. Fuertes, M. Bejarano, V. Barrera, J. C. Caicedo
{"title":"化学计量比为 57/43 的 Si3N4 二元涂层的摩擦系数演变","authors":"C. H. Ortiz, J. M. Fuertes, M. Bejarano, V. Barrera, J. C. Caicedo","doi":"10.1007/s11249-024-01909-6","DOIUrl":null,"url":null,"abstract":"<div><p>Friction coefficient depends on various factors or surface characteristics during tribological testing, and this friction coefficient can be modified by altering the properties of one of the two contacting surfaces. It is crucial to monitor the friction coefficient continuously, not only at the conclusion of the test. This research examined the evolution of friction coefficient of silicon nitride (Si<sub>3</sub>N<sub>4</sub>) coating and H13 steel over different sliding distances (250, 500, 750, 1000 m). The study assessed surface wear and oxidation through three-dimensional profilometry and SEM/EDX. The findings indicated a reduction in friction coefficient by 22%, a decrease in wear rate by 88%, and a reduction in wear volume by 87% when comparing the silicon nitride coated steel to the uncoated steel. Furthermore, the changes in friction coefficient provided insights into the timing of the complete fracture of the hard coating.</p><h3>Graphical abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":806,"journal":{"name":"Tribology Letters","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s11249-024-01909-6.pdf","citationCount":"0","resultStr":"{\"title\":\"Friction Coefficient Evolution of Si3N4 Binary Coating with a Stoichiometric Ratio of 57/43\",\"authors\":\"C. H. Ortiz, J. M. Fuertes, M. Bejarano, V. Barrera, J. C. Caicedo\",\"doi\":\"10.1007/s11249-024-01909-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Friction coefficient depends on various factors or surface characteristics during tribological testing, and this friction coefficient can be modified by altering the properties of one of the two contacting surfaces. It is crucial to monitor the friction coefficient continuously, not only at the conclusion of the test. This research examined the evolution of friction coefficient of silicon nitride (Si<sub>3</sub>N<sub>4</sub>) coating and H13 steel over different sliding distances (250, 500, 750, 1000 m). The study assessed surface wear and oxidation through three-dimensional profilometry and SEM/EDX. The findings indicated a reduction in friction coefficient by 22%, a decrease in wear rate by 88%, and a reduction in wear volume by 87% when comparing the silicon nitride coated steel to the uncoated steel. Furthermore, the changes in friction coefficient provided insights into the timing of the complete fracture of the hard coating.</p><h3>Graphical abstract</h3>\\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>\",\"PeriodicalId\":806,\"journal\":{\"name\":\"Tribology Letters\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-09-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s11249-024-01909-6.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Tribology Letters\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s11249-024-01909-6\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, CHEMICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tribology Letters","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s11249-024-01909-6","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
Friction Coefficient Evolution of Si3N4 Binary Coating with a Stoichiometric Ratio of 57/43
Friction coefficient depends on various factors or surface characteristics during tribological testing, and this friction coefficient can be modified by altering the properties of one of the two contacting surfaces. It is crucial to monitor the friction coefficient continuously, not only at the conclusion of the test. This research examined the evolution of friction coefficient of silicon nitride (Si3N4) coating and H13 steel over different sliding distances (250, 500, 750, 1000 m). The study assessed surface wear and oxidation through three-dimensional profilometry and SEM/EDX. The findings indicated a reduction in friction coefficient by 22%, a decrease in wear rate by 88%, and a reduction in wear volume by 87% when comparing the silicon nitride coated steel to the uncoated steel. Furthermore, the changes in friction coefficient provided insights into the timing of the complete fracture of the hard coating.
期刊介绍:
Tribology Letters is devoted to the development of the science of tribology and its applications, particularly focusing on publishing high-quality papers at the forefront of tribological science and that address the fundamentals of friction, lubrication, wear, or adhesion. The journal facilitates communication and exchange of seminal ideas among thousands of practitioners who are engaged worldwide in the pursuit of tribology-based science and technology.