唐氏综合症游泳运动员最大强度前爬泳的局限性

Q1 Mathematics
Giampiero Merati, Damiano Formenti, Claudio Gandola, Paolo Castiglioni, Linda Casalini, Athos Trecroci, Luca Cavaggioni, Pietro Luigi Invernizzi, Umberto Menichino, Raffaele Scurati
{"title":"唐氏综合症游泳运动员最大强度前爬泳的局限性","authors":"Giampiero Merati, Damiano Formenti, Claudio Gandola, Paolo Castiglioni, Linda Casalini, Athos Trecroci, Luca Cavaggioni, Pietro Luigi Invernizzi, Umberto Menichino, Raffaele Scurati","doi":"10.3390/app14188387","DOIUrl":null,"url":null,"abstract":"Individuals with Down Syndrome exhibit deficits in muscle strength and cardiovascular adaptation, which limit athletic performance. We compared a maximum-intensity 50 m front crawl test between competitive male swimmers with Down Syndrome (SDS; n = 11; 26.5 ± 5.6 years; m ± SD) and a control group of swimmers (CNT; n = 11; 27.1 ± 4.0 years) with similar training routines (about 5 h/week). Wearable sternal sensors measured their heart rate and 3D accelerometry. The regularity index Sample Entropy (SampEn) was calculated using the X component of acceleration. The total times (SDS: 58.91 ± 13.68 s; CNT: 32.55 ± 3.70 s) and stroke counts (SDS: 66.1 ± 9.6; CNT: 51.4 ± 7.4) were significantly higher in the SDS group (p < 0.01). The heart rate was lower in the SDS group during immediate (SDS: 129 ± 15 bpm; CNT: 172 ± 11 bpm) and delayed recovery (30 s, SDS: 104 ± 23 bpm; CNT: 145 ± 21 bpm; 60 s, SDS: 79 ± 27 bpm; CNT: 114 ± 27 bpm) (p < 0.01 for all the comparisons). The SampEn of sternal acceleration showed no differences between the groups and between 0–25 m and 25–50 m. Body pitch correlated strongly with performance in the SDSs (R2 = 0.632, p < 0.01), but during the first 25 m only. The high-intensity front crawl performances differed between the SDS and CNT athletes in terms of time, biomechanics, and training adaptation, suggesting the need for tailored training to improve swimming efficiency in SDSs.","PeriodicalId":8224,"journal":{"name":"Applied Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Limitations in Maximum Intensity Front Crawl in Swimmers with Down Syndrome\",\"authors\":\"Giampiero Merati, Damiano Formenti, Claudio Gandola, Paolo Castiglioni, Linda Casalini, Athos Trecroci, Luca Cavaggioni, Pietro Luigi Invernizzi, Umberto Menichino, Raffaele Scurati\",\"doi\":\"10.3390/app14188387\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Individuals with Down Syndrome exhibit deficits in muscle strength and cardiovascular adaptation, which limit athletic performance. We compared a maximum-intensity 50 m front crawl test between competitive male swimmers with Down Syndrome (SDS; n = 11; 26.5 ± 5.6 years; m ± SD) and a control group of swimmers (CNT; n = 11; 27.1 ± 4.0 years) with similar training routines (about 5 h/week). Wearable sternal sensors measured their heart rate and 3D accelerometry. The regularity index Sample Entropy (SampEn) was calculated using the X component of acceleration. The total times (SDS: 58.91 ± 13.68 s; CNT: 32.55 ± 3.70 s) and stroke counts (SDS: 66.1 ± 9.6; CNT: 51.4 ± 7.4) were significantly higher in the SDS group (p < 0.01). The heart rate was lower in the SDS group during immediate (SDS: 129 ± 15 bpm; CNT: 172 ± 11 bpm) and delayed recovery (30 s, SDS: 104 ± 23 bpm; CNT: 145 ± 21 bpm; 60 s, SDS: 79 ± 27 bpm; CNT: 114 ± 27 bpm) (p < 0.01 for all the comparisons). The SampEn of sternal acceleration showed no differences between the groups and between 0–25 m and 25–50 m. Body pitch correlated strongly with performance in the SDSs (R2 = 0.632, p < 0.01), but during the first 25 m only. The high-intensity front crawl performances differed between the SDS and CNT athletes in terms of time, biomechanics, and training adaptation, suggesting the need for tailored training to improve swimming efficiency in SDSs.\",\"PeriodicalId\":8224,\"journal\":{\"name\":\"Applied Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/app14188387\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Mathematics\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/app14188387","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Mathematics","Score":null,"Total":0}
引用次数: 0

摘要

唐氏综合症患者在肌肉力量和心血管适应方面存在缺陷,从而限制了他们的运动表现。我们比较了唐氏综合症男性游泳运动员(SDS;n = 11;26.5 ± 5.6 岁;m ± SD)和对照组游泳运动员(CNT;n = 11;27.1 ± 4.0 岁)的最大强度 50 米前爬泳测试,他们的训练程序相似(约 5 小时/周)。胸骨佩戴式传感器测量了他们的心率和三维加速度。利用加速度的 X 分量计算规律性指数样本熵(SampEn)。SDS 组的总时间(SDS:58.91 ± 13.68 秒;CNT:32.55 ± 3.70 秒)和划动次数(SDS:66.1 ± 9.6;CNT:51.4 ± 7.4)明显高于 CNT 组(P < 0.01)。在即时恢复(SDS:129 ± 15 bpm;CNT:172 ± 11 bpm)和延迟恢复(30 秒,SDS:104 ± 23 bpm;CNT:145 ± 21 bpm;60 秒,SDS:79 ± 27 bpm;CNT:114 ± 27 bpm)期间,SDS 组的心率较低(所有比较中,P < 0.01)。胸骨加速度的 SampEn 在各组之间以及在 0-25 米和 25-50 米之间均无差异。SDS 和 CNT 运动员的高强度前爬泳成绩在时间、生物力学和训练适应性方面存在差异,这表明有必要进行有针对性的训练,以提高 SDS 的游泳效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Limitations in Maximum Intensity Front Crawl in Swimmers with Down Syndrome
Individuals with Down Syndrome exhibit deficits in muscle strength and cardiovascular adaptation, which limit athletic performance. We compared a maximum-intensity 50 m front crawl test between competitive male swimmers with Down Syndrome (SDS; n = 11; 26.5 ± 5.6 years; m ± SD) and a control group of swimmers (CNT; n = 11; 27.1 ± 4.0 years) with similar training routines (about 5 h/week). Wearable sternal sensors measured their heart rate and 3D accelerometry. The regularity index Sample Entropy (SampEn) was calculated using the X component of acceleration. The total times (SDS: 58.91 ± 13.68 s; CNT: 32.55 ± 3.70 s) and stroke counts (SDS: 66.1 ± 9.6; CNT: 51.4 ± 7.4) were significantly higher in the SDS group (p < 0.01). The heart rate was lower in the SDS group during immediate (SDS: 129 ± 15 bpm; CNT: 172 ± 11 bpm) and delayed recovery (30 s, SDS: 104 ± 23 bpm; CNT: 145 ± 21 bpm; 60 s, SDS: 79 ± 27 bpm; CNT: 114 ± 27 bpm) (p < 0.01 for all the comparisons). The SampEn of sternal acceleration showed no differences between the groups and between 0–25 m and 25–50 m. Body pitch correlated strongly with performance in the SDSs (R2 = 0.632, p < 0.01), but during the first 25 m only. The high-intensity front crawl performances differed between the SDS and CNT athletes in terms of time, biomechanics, and training adaptation, suggesting the need for tailored training to improve swimming efficiency in SDSs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applied Sciences
Applied Sciences Mathematics-Applied Mathematics
CiteScore
6.40
自引率
0.00%
发文量
0
审稿时长
11 weeks
期刊介绍: APPS is an international journal. APPS covers a wide spectrum of pure and applied mathematics in science and technology, promoting especially papers presented at Carpato-Balkan meetings. The Editorial Board of APPS takes a very active role in selecting and refereeing papers, ensuring the best quality of contemporary mathematics and its applications. APPS is abstracted in Zentralblatt für Mathematik. The APPS journal uses Double blind peer review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信