应用基于齐聚物离子液体的胶囊相微萃取技术进行高效液相色谱-紫外检测人体尿样中的强力霉素

IF 2.8 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS
Dafni Melissaropoulou , Marianna Ntorkou , Paraskevas D. Tzanavaras , Abuzar Kabir , Constantinos K. Zacharis
{"title":"应用基于齐聚物离子液体的胶囊相微萃取技术进行高效液相色谱-紫外检测人体尿样中的强力霉素","authors":"Dafni Melissaropoulou ,&nbsp;Marianna Ntorkou ,&nbsp;Paraskevas D. Tzanavaras ,&nbsp;Abuzar Kabir ,&nbsp;Constantinos K. Zacharis","doi":"10.1016/j.jchromb.2024.124320","DOIUrl":null,"url":null,"abstract":"<div><p>Herein, we describe the utilization of an ionic liquid (IL)/Carbowax 20 M−functionalized sol–gel sorbent for the capsule phase microextraction of doxycycline in authentic human urine samples. This green sample preparation method combines stirring and filtration in a single, standalone sample preparation device, streamlining the sample preparation process. Additionally, it provides rapid extraction kinetics and high extraction efficiency. The experimental conditions (i.e. sorbent type, sample pH and volume, extraction time, ionic strength, elution solvent, and volume) affecting the extraction efficiency of the analyte were studied and optimized. The method was linear in the range of 0.1 – 5.0 μg/mL with a coefficient of determination higher than 0.995. The achieved LOD was found to be 0.02 μg/mL while the lower limit of quantitation (LLOQ) was 0.1 μg/mL. The IL/Carbowax 20 M−functionalized microextraction capsules were reusable at least 30 times for urine samples. The relative recoveries (% RR) ranged between 93.4 – 115.9 % while the precision (expressed as % RSD) was better than 8.1 % in all cases. The robustness of the microextraction procedure and the instrumental HPLC method were separately investigated using Plackett-Burman experimental designs. The analytical protocol demonstrated cost-effectiveness, ease of handling, and speed, leading to increased sample throughput. The green character of the developed method was evaluated using the Green Analytical Procedure Index (GAPI) and Blue Applicability Grade Index (BAGI). Finally, the method’s applicability was demonstrated by analyzing authentic human urine samples after oral administration of a doxycycline-containing pharmaceutical formulation.</p></div>","PeriodicalId":348,"journal":{"name":"Journal of Chromatography B","volume":"1247 ","pages":"Article 124320"},"PeriodicalIF":2.8000,"publicationDate":"2024-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application of zwitterionic ionic liquid-based capsule phase microextraction for the HPLC-UV determination of doxycycline in human urine samples\",\"authors\":\"Dafni Melissaropoulou ,&nbsp;Marianna Ntorkou ,&nbsp;Paraskevas D. Tzanavaras ,&nbsp;Abuzar Kabir ,&nbsp;Constantinos K. Zacharis\",\"doi\":\"10.1016/j.jchromb.2024.124320\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Herein, we describe the utilization of an ionic liquid (IL)/Carbowax 20 M−functionalized sol–gel sorbent for the capsule phase microextraction of doxycycline in authentic human urine samples. This green sample preparation method combines stirring and filtration in a single, standalone sample preparation device, streamlining the sample preparation process. Additionally, it provides rapid extraction kinetics and high extraction efficiency. The experimental conditions (i.e. sorbent type, sample pH and volume, extraction time, ionic strength, elution solvent, and volume) affecting the extraction efficiency of the analyte were studied and optimized. The method was linear in the range of 0.1 – 5.0 μg/mL with a coefficient of determination higher than 0.995. The achieved LOD was found to be 0.02 μg/mL while the lower limit of quantitation (LLOQ) was 0.1 μg/mL. The IL/Carbowax 20 M−functionalized microextraction capsules were reusable at least 30 times for urine samples. The relative recoveries (% RR) ranged between 93.4 – 115.9 % while the precision (expressed as % RSD) was better than 8.1 % in all cases. The robustness of the microextraction procedure and the instrumental HPLC method were separately investigated using Plackett-Burman experimental designs. The analytical protocol demonstrated cost-effectiveness, ease of handling, and speed, leading to increased sample throughput. The green character of the developed method was evaluated using the Green Analytical Procedure Index (GAPI) and Blue Applicability Grade Index (BAGI). Finally, the method’s applicability was demonstrated by analyzing authentic human urine samples after oral administration of a doxycycline-containing pharmaceutical formulation.</p></div>\",\"PeriodicalId\":348,\"journal\":{\"name\":\"Journal of Chromatography B\",\"volume\":\"1247 \",\"pages\":\"Article 124320\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-09-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Chromatography B\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1570023224003295\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography B","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1570023224003295","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

在此,我们介绍了利用离子液体(IL)/Carbowax 20 M 功能化溶胶-凝胶吸附剂对真实人体尿液样品中的强力霉素进行胶囊相微萃取的方法。这种绿色样品制备方法将搅拌和过滤结合在一个独立的样品制备装置中,简化了样品制备过程。此外,该方法还具有快速的萃取动力学和较高的萃取效率。研究并优化了影响分析物萃取效率的实验条件(即吸附剂类型、样品 pH 值和体积、萃取时间、离子强度、洗脱溶剂和体积)。该方法在 0.1 - 5.0 μg/mL 范围内线性关系良好,测定系数大于 0.995。检测限(LOD)为 0.02 μg/mL,定量下限(LLOQ)为 0.1 μg/mL。对于尿样,IL/Carbowax 20 M 功能化微萃取胶囊可重复使用至少 30 次。相对回收率(% RR)在 93.4 - 115.9 % 之间,而精确度(以 % RSD 表示)在所有情况下均优于 8.1 %。采用 Plackett-Burman 实验设计分别研究了微萃取程序和仪器 HPLC 方法的稳健性。该分析方案具有成本效益高、操作简便、速度快等特点,从而提高了样品处理量。使用绿色分析程序指数(GAPI)和蓝色适用性等级指数(BAGI)评估了所开发方法的绿色特性。最后,通过分析口服含多西环素药物制剂后的真实人体尿样,证明了该方法的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application of zwitterionic ionic liquid-based capsule phase microextraction for the HPLC-UV determination of doxycycline in human urine samples

Herein, we describe the utilization of an ionic liquid (IL)/Carbowax 20 M−functionalized sol–gel sorbent for the capsule phase microextraction of doxycycline in authentic human urine samples. This green sample preparation method combines stirring and filtration in a single, standalone sample preparation device, streamlining the sample preparation process. Additionally, it provides rapid extraction kinetics and high extraction efficiency. The experimental conditions (i.e. sorbent type, sample pH and volume, extraction time, ionic strength, elution solvent, and volume) affecting the extraction efficiency of the analyte were studied and optimized. The method was linear in the range of 0.1 – 5.0 μg/mL with a coefficient of determination higher than 0.995. The achieved LOD was found to be 0.02 μg/mL while the lower limit of quantitation (LLOQ) was 0.1 μg/mL. The IL/Carbowax 20 M−functionalized microextraction capsules were reusable at least 30 times for urine samples. The relative recoveries (% RR) ranged between 93.4 – 115.9 % while the precision (expressed as % RSD) was better than 8.1 % in all cases. The robustness of the microextraction procedure and the instrumental HPLC method were separately investigated using Plackett-Burman experimental designs. The analytical protocol demonstrated cost-effectiveness, ease of handling, and speed, leading to increased sample throughput. The green character of the developed method was evaluated using the Green Analytical Procedure Index (GAPI) and Blue Applicability Grade Index (BAGI). Finally, the method’s applicability was demonstrated by analyzing authentic human urine samples after oral administration of a doxycycline-containing pharmaceutical formulation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Chromatography B
Journal of Chromatography B 医学-分析化学
CiteScore
5.60
自引率
3.30%
发文量
306
审稿时长
44 days
期刊介绍: The Journal of Chromatography B publishes papers on developments in separation science relevant to biology and biomedical research including both fundamental advances and applications. Analytical techniques which may be considered include the various facets of chromatography, electrophoresis and related methods, affinity and immunoaffinity-based methodologies, hyphenated and other multi-dimensional techniques, and microanalytical approaches. The journal also considers articles reporting developments in sample preparation, detection techniques including mass spectrometry, and data handling and analysis. Developments related to preparative separations for the isolation and purification of components of biological systems may be published, including chromatographic and electrophoretic methods, affinity separations, field flow fractionation and other preparative approaches. Applications to the analysis of biological systems and samples will be considered when the analytical science contains a significant element of novelty, e.g. a new approach to the separation of a compound, novel combination of analytical techniques, or significantly improved analytical performance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信