Morgan L. Denzer, Morgan Pfeiffer, Gretchen Mafi, Ranjith Ramanathan
{"title":"将高铁血红蛋白水平纳入基于反射率的耗氧量测量的重要性","authors":"Morgan L. Denzer, Morgan Pfeiffer, Gretchen Mafi, Ranjith Ramanathan","doi":"10.1016/j.meatsci.2024.109651","DOIUrl":null,"url":null,"abstract":"<div><p>Reflectance-based oxygen consumption measurement utilizes changes in oxymyoglobin levels between bloomed and vacuum-packaged meat, assuming that oxymyoglobin is converted to deoxymyoglobin. However, the interconversion of oxymyoglobin to deoxymyoglobin depends on the age of the meat and the length of display; hence, oxygen consumption calculations might yield inaccurate interpretations if deoxymyoglobin is not the final form. The objective was to evaluate the effectiveness of determining metmyoglobin levels during oxygen consumption analysis and its relationship to beef color stability. Seven <em>psoas major</em> (color labile) and <em>longissimus</em> (color stable) were displayed in retail for 6 d and evaluated for oxygen consumption on the retail (oxygen exposed) and interior (non‑oxygen exposed) surfaces. The retail surface had greater (<em>P</em> < 0.05) metmyoglobin formed during oxygen consumption than the interior surface on d 6 of the display. Furthermore, the <em>psoas major</em> muscle exhibited greater (<em>P</em> < 0.05) metmyoglobin content during oxygen consumption than the <em>longissimus</em> on the retail surface paralleling with the decline in color stability. Therefore, the study indicates that sampling location and including metmyoglobin content in oxygen consumption calculations, along with changes in oxymyoglobin, will better explain meat color stability.</p></div>","PeriodicalId":389,"journal":{"name":"Meat Science","volume":"219 ","pages":"Article 109651"},"PeriodicalIF":7.1000,"publicationDate":"2024-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The importance of including metmyoglobin levels in reflectance-based oxygen consumption measurements\",\"authors\":\"Morgan L. Denzer, Morgan Pfeiffer, Gretchen Mafi, Ranjith Ramanathan\",\"doi\":\"10.1016/j.meatsci.2024.109651\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Reflectance-based oxygen consumption measurement utilizes changes in oxymyoglobin levels between bloomed and vacuum-packaged meat, assuming that oxymyoglobin is converted to deoxymyoglobin. However, the interconversion of oxymyoglobin to deoxymyoglobin depends on the age of the meat and the length of display; hence, oxygen consumption calculations might yield inaccurate interpretations if deoxymyoglobin is not the final form. The objective was to evaluate the effectiveness of determining metmyoglobin levels during oxygen consumption analysis and its relationship to beef color stability. Seven <em>psoas major</em> (color labile) and <em>longissimus</em> (color stable) were displayed in retail for 6 d and evaluated for oxygen consumption on the retail (oxygen exposed) and interior (non‑oxygen exposed) surfaces. The retail surface had greater (<em>P</em> < 0.05) metmyoglobin formed during oxygen consumption than the interior surface on d 6 of the display. Furthermore, the <em>psoas major</em> muscle exhibited greater (<em>P</em> < 0.05) metmyoglobin content during oxygen consumption than the <em>longissimus</em> on the retail surface paralleling with the decline in color stability. Therefore, the study indicates that sampling location and including metmyoglobin content in oxygen consumption calculations, along with changes in oxymyoglobin, will better explain meat color stability.</p></div>\",\"PeriodicalId\":389,\"journal\":{\"name\":\"Meat Science\",\"volume\":\"219 \",\"pages\":\"Article 109651\"},\"PeriodicalIF\":7.1000,\"publicationDate\":\"2024-09-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Meat Science\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0309174024002286\",\"RegionNum\":1,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Agricultural and Biological Sciences\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Meat Science","FirstCategoryId":"97","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0309174024002286","RegionNum":1,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Agricultural and Biological Sciences","Score":null,"Total":0}
The importance of including metmyoglobin levels in reflectance-based oxygen consumption measurements
Reflectance-based oxygen consumption measurement utilizes changes in oxymyoglobin levels between bloomed and vacuum-packaged meat, assuming that oxymyoglobin is converted to deoxymyoglobin. However, the interconversion of oxymyoglobin to deoxymyoglobin depends on the age of the meat and the length of display; hence, oxygen consumption calculations might yield inaccurate interpretations if deoxymyoglobin is not the final form. The objective was to evaluate the effectiveness of determining metmyoglobin levels during oxygen consumption analysis and its relationship to beef color stability. Seven psoas major (color labile) and longissimus (color stable) were displayed in retail for 6 d and evaluated for oxygen consumption on the retail (oxygen exposed) and interior (non‑oxygen exposed) surfaces. The retail surface had greater (P < 0.05) metmyoglobin formed during oxygen consumption than the interior surface on d 6 of the display. Furthermore, the psoas major muscle exhibited greater (P < 0.05) metmyoglobin content during oxygen consumption than the longissimus on the retail surface paralleling with the decline in color stability. Therefore, the study indicates that sampling location and including metmyoglobin content in oxygen consumption calculations, along with changes in oxymyoglobin, will better explain meat color stability.
期刊介绍:
The aim of Meat Science is to serve as a suitable platform for the dissemination of interdisciplinary and international knowledge on all factors influencing the properties of meat. While the journal primarily focuses on the flesh of mammals, contributions related to poultry will be considered if they enhance the overall understanding of the relationship between muscle nature and meat quality post mortem. Additionally, papers on large birds (e.g., emus, ostriches) as well as wild-captured mammals and crocodiles will be welcomed.