使用 KISA% 指数对渐进性角膜病眼球进行错误分类。

IF 2.9 3区 医学 Q1 OPHTHALMOLOGY
Bassel Hammoud,William J Dupps,Giuliano Scarcelli,J Bradley Randleman
{"title":"使用 KISA% 指数对渐进性角膜病眼球进行错误分类。","authors":"Bassel Hammoud,William J Dupps,Giuliano Scarcelli,J Bradley Randleman","doi":"10.3928/1081597x-20240726-01","DOIUrl":null,"url":null,"abstract":"PURPOSE\r\nTo determine the misclassification rate of the keratoconus percentage (KISA%) index efficacy in eyes with progressive keratoconus.\r\n\r\nMETHODS\r\nThis was a retrospective case-control study of consecutive patients with confirmed progressive keratoconus and a contemporaneous normal control group with 1.00 diopters or greater regular astigmatism. Scheimpflug imaging (Pentacam HR) was obtained for all patients. KISA% index and inferior-superior (IS) values were obtained from the Pentacam topometric/keratoconus staging map. Receiver operating characteristic curves were generated to determine the area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity values.\r\n\r\nRESULTS\r\nThere were 160 eyes from 160 patients evaluated, including 80 eyes from 80 patients with progressive keratoconus and 80 eyes from 80 control patients. There were 20 eyes (25%) with progressive keratoconus misclassified by the KISA% index, with 16 eyes (20%) of the progressive keratoconus cohort classified as normal (ie, KISA% < 60). There were 4 eyes (5%) with progressive keratoconus that would classify as having \"normal topography\" using the published criteria for very asymmetric ectasia with normal topography of KISA% less than 60 and IS value less than 1.45. All controls had a KISA% index value of less than 15. The optimal cut-off value to distinguish cohorts was 15.31 (AUROC = 0.972, 93.75% sensitivity). KISA% index values of 60 and 100 achieved low sensitivity (80% and 73.75%, respectively).\r\n\r\nCONCLUSIONS\r\nThe KISA% index misclassified a significant proportion of eyes with progressive keratoconus as normal. Although highly specific for clinical keratoconus, the KISA% index lacks sensitivity, does not effectively discriminate between normal and abnormal topography, and thus should not be used in large data analysis or artificial intelligence-based modeling. [J Refract Surg. 2024;40(9):e614-e624.].","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"39 1","pages":"e614-e624"},"PeriodicalIF":2.9000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Misclassification of Eyes With Progressive Keratoconus Using the KISA% Index.\",\"authors\":\"Bassel Hammoud,William J Dupps,Giuliano Scarcelli,J Bradley Randleman\",\"doi\":\"10.3928/1081597x-20240726-01\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"PURPOSE\\r\\nTo determine the misclassification rate of the keratoconus percentage (KISA%) index efficacy in eyes with progressive keratoconus.\\r\\n\\r\\nMETHODS\\r\\nThis was a retrospective case-control study of consecutive patients with confirmed progressive keratoconus and a contemporaneous normal control group with 1.00 diopters or greater regular astigmatism. Scheimpflug imaging (Pentacam HR) was obtained for all patients. KISA% index and inferior-superior (IS) values were obtained from the Pentacam topometric/keratoconus staging map. Receiver operating characteristic curves were generated to determine the area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity values.\\r\\n\\r\\nRESULTS\\r\\nThere were 160 eyes from 160 patients evaluated, including 80 eyes from 80 patients with progressive keratoconus and 80 eyes from 80 control patients. There were 20 eyes (25%) with progressive keratoconus misclassified by the KISA% index, with 16 eyes (20%) of the progressive keratoconus cohort classified as normal (ie, KISA% < 60). There were 4 eyes (5%) with progressive keratoconus that would classify as having \\\"normal topography\\\" using the published criteria for very asymmetric ectasia with normal topography of KISA% less than 60 and IS value less than 1.45. All controls had a KISA% index value of less than 15. The optimal cut-off value to distinguish cohorts was 15.31 (AUROC = 0.972, 93.75% sensitivity). KISA% index values of 60 and 100 achieved low sensitivity (80% and 73.75%, respectively).\\r\\n\\r\\nCONCLUSIONS\\r\\nThe KISA% index misclassified a significant proportion of eyes with progressive keratoconus as normal. Although highly specific for clinical keratoconus, the KISA% index lacks sensitivity, does not effectively discriminate between normal and abnormal topography, and thus should not be used in large data analysis or artificial intelligence-based modeling. [J Refract Surg. 2024;40(9):e614-e624.].\",\"PeriodicalId\":16951,\"journal\":{\"name\":\"Journal of refractive surgery\",\"volume\":\"39 1\",\"pages\":\"e614-e624\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3928/1081597x-20240726-01\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597x-20240726-01","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的确定渐进性角膜炎患者角膜屈光度百分比(KISA%)指数疗效的误判率。方法这是一项回顾性病例对照研究,研究对象是确诊为渐进性角膜炎的连续患者,以及同时具有 1.00 斜度或更大规则散光的正常对照组。所有患者均获得了 Scheimpflug 成像(Pentacam HR)。从 Pentacam 地形测量/角膜病分期图中获得 KISA% 指数和下-上 (IS) 值。结果共评估了 160 名患者的 160 只眼睛,包括 80 名进行性角膜病患者的 80 只眼睛和 80 名对照组患者的 80 只眼睛。有 20 只眼睛(25%)的进行性角膜病被 KISA% 指数错误分类,16 只眼睛(20%)的进行性角膜病被分类为正常(即 KISA% < 60)。有 4 只(5%)渐进性角膜病患者的 KISA% 指数小于 60 且 IS 值小于 1.45,根据已公布的 KISA% 指数小于 60 且 IS 值小于 1.45 的极不对称异位正常地形图标准,这 4 只眼会被归类为 "正常地形图"。所有对照组的 KISA% 指数值均小于 15。区分组群的最佳临界值为 15.31(AUROC = 0.972,灵敏度为 93.75%)。KISA% 指数值为 60 和 100 时,灵敏度较低(分别为 80% 和 73.75%)。虽然 KISA% 指数对临床角膜病具有高度特异性,但它缺乏灵敏度,不能有效区分正常和异常地形图,因此不应在大数据分析或基于人工智能的建模中使用。[J Refract Surg. 2024;40(9):e614-e624]。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Misclassification of Eyes With Progressive Keratoconus Using the KISA% Index.
PURPOSE To determine the misclassification rate of the keratoconus percentage (KISA%) index efficacy in eyes with progressive keratoconus. METHODS This was a retrospective case-control study of consecutive patients with confirmed progressive keratoconus and a contemporaneous normal control group with 1.00 diopters or greater regular astigmatism. Scheimpflug imaging (Pentacam HR) was obtained for all patients. KISA% index and inferior-superior (IS) values were obtained from the Pentacam topometric/keratoconus staging map. Receiver operating characteristic curves were generated to determine the area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity values. RESULTS There were 160 eyes from 160 patients evaluated, including 80 eyes from 80 patients with progressive keratoconus and 80 eyes from 80 control patients. There were 20 eyes (25%) with progressive keratoconus misclassified by the KISA% index, with 16 eyes (20%) of the progressive keratoconus cohort classified as normal (ie, KISA% < 60). There were 4 eyes (5%) with progressive keratoconus that would classify as having "normal topography" using the published criteria for very asymmetric ectasia with normal topography of KISA% less than 60 and IS value less than 1.45. All controls had a KISA% index value of less than 15. The optimal cut-off value to distinguish cohorts was 15.31 (AUROC = 0.972, 93.75% sensitivity). KISA% index values of 60 and 100 achieved low sensitivity (80% and 73.75%, respectively). CONCLUSIONS The KISA% index misclassified a significant proportion of eyes with progressive keratoconus as normal. Although highly specific for clinical keratoconus, the KISA% index lacks sensitivity, does not effectively discriminate between normal and abnormal topography, and thus should not be used in large data analysis or artificial intelligence-based modeling. [J Refract Surg. 2024;40(9):e614-e624.].
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信