利用光学相干断层扫描评估原发性开角型青光眼和假性角膜外翻型青光眼的角膜板层参数、神经纤维厚度和黄斑厚度

IF 1.4 4区 医学 Q3 OPHTHALMOLOGY
Burhan Baskan, Mustafa Atas, Suleyman Demircan
{"title":"利用光学相干断层扫描评估原发性开角型青光眼和假性角膜外翻型青光眼的角膜板层参数、神经纤维厚度和黄斑厚度","authors":"Burhan Baskan, Mustafa Atas, Suleyman Demircan","doi":"10.1007/s10792-024-03288-2","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Purpose</h3><p>To evaluate the lamina cribrosa, retinal nerve fiber layer (RNFL), and macula in patients with primary open-angle glaucoma (POAG) and pseudoexfoliation glaucoma (PEXG) and healthy individuals using enhanced depth imaging (EDI) of spectral-domain optical coherence tomography (SD-OCT).</p><h3 data-test=\"abstract-sub-heading\">Methods</h3><p>A total of 158 eyes were included in the study, comprising 58 eyes of 29 patients with POAG, 50 eyes of 25 patients with PEXG, and 50 eyes of 25 healthy individuals. The lamina cribrosa thickness (LCT) (at three locations), lamina cribrosa depth (LCD), RNFL thickness, and the macular thickness were measured using the EDI mode of the SD-OCT. The results were compared among the three groups.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>In both POAG and PEXG groups, the LCT was significantly thinner in the center, mid-superior, and mid-inferior areas in both eyes than in the control group (<i>p</i> &lt; 0.001). However, no statistically significant difference was observed between the POAG and PEXG groups in terms of LCT at all three measurement locations in both eyes (<i>p</i> &gt; 0.05). The LCD was significantly lower in the control group compared to the POAG and PEXG groups (<i>p</i> &lt; 0.05), but there was no significant difference between the POAG and PEXG groups (<i>p</i> &gt; 0.05). The RNFL thickness was significantly lower in both the POAG and PEXG groups compared to the control group in both eyes (<i>p</i> &lt; 0.05).</p><h3 data-test=\"abstract-sub-heading\">Conclusion</h3><p>The LCT and LCD of patients with POAG and PEXG were thinner than those of healthy individuals, but there was no significant difference between the patients with POAG and PEXG.</p>","PeriodicalId":14473,"journal":{"name":"International Ophthalmology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of lamina cribrosa parameters, nerve fiber thickness, and macular thickness in primary open-angle glaucoma and pseudoexfoliation glaucoma using optical coherence tomography\",\"authors\":\"Burhan Baskan, Mustafa Atas, Suleyman Demircan\",\"doi\":\"10.1007/s10792-024-03288-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<h3 data-test=\\\"abstract-sub-heading\\\">Purpose</h3><p>To evaluate the lamina cribrosa, retinal nerve fiber layer (RNFL), and macula in patients with primary open-angle glaucoma (POAG) and pseudoexfoliation glaucoma (PEXG) and healthy individuals using enhanced depth imaging (EDI) of spectral-domain optical coherence tomography (SD-OCT).</p><h3 data-test=\\\"abstract-sub-heading\\\">Methods</h3><p>A total of 158 eyes were included in the study, comprising 58 eyes of 29 patients with POAG, 50 eyes of 25 patients with PEXG, and 50 eyes of 25 healthy individuals. The lamina cribrosa thickness (LCT) (at three locations), lamina cribrosa depth (LCD), RNFL thickness, and the macular thickness were measured using the EDI mode of the SD-OCT. The results were compared among the three groups.</p><h3 data-test=\\\"abstract-sub-heading\\\">Results</h3><p>In both POAG and PEXG groups, the LCT was significantly thinner in the center, mid-superior, and mid-inferior areas in both eyes than in the control group (<i>p</i> &lt; 0.001). However, no statistically significant difference was observed between the POAG and PEXG groups in terms of LCT at all three measurement locations in both eyes (<i>p</i> &gt; 0.05). The LCD was significantly lower in the control group compared to the POAG and PEXG groups (<i>p</i> &lt; 0.05), but there was no significant difference between the POAG and PEXG groups (<i>p</i> &gt; 0.05). The RNFL thickness was significantly lower in both the POAG and PEXG groups compared to the control group in both eyes (<i>p</i> &lt; 0.05).</p><h3 data-test=\\\"abstract-sub-heading\\\">Conclusion</h3><p>The LCT and LCD of patients with POAG and PEXG were thinner than those of healthy individuals, but there was no significant difference between the patients with POAG and PEXG.</p>\",\"PeriodicalId\":14473,\"journal\":{\"name\":\"International Ophthalmology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-09-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10792-024-03288-2\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10792-024-03288-2","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的 使用光谱域光学相干断层成像仪(SD-OCT)的增强深度成像(EDI)评估原发性开角型青光眼(POAG)和假性开角型青光眼(PEXG)患者以及健康人的颅底薄层、视网膜神经纤维层(RNFL)和黄斑。研究人员使用 SD-OCT 的 EDI 模式测量了三个位置的巩膜厚度 (LCT)、巩膜深度 (LCD)、RNFL 厚度和黄斑厚度。结果在 POAG 组和 PEXG 组中,双眼中央、中上方和中下方区域的 LCT 都明显比对照组薄(p < 0.001)。然而,POAG 组和 PEXG 组双眼所有三个测量位置的 LCT 均无明显统计学差异(p > 0.05)。对照组的 LCD 明显低于 POAG 组和 PEXG 组(p < 0.05),但 POAG 组和 PEXG 组之间没有明显差异(p > 0.05)。结论 POAG 和 PEXG 患者的 LCT 和 LCD 比健康人薄,但 POAG 和 PEXG 患者之间无明显差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Evaluation of lamina cribrosa parameters, nerve fiber thickness, and macular thickness in primary open-angle glaucoma and pseudoexfoliation glaucoma using optical coherence tomography

Evaluation of lamina cribrosa parameters, nerve fiber thickness, and macular thickness in primary open-angle glaucoma and pseudoexfoliation glaucoma using optical coherence tomography

Purpose

To evaluate the lamina cribrosa, retinal nerve fiber layer (RNFL), and macula in patients with primary open-angle glaucoma (POAG) and pseudoexfoliation glaucoma (PEXG) and healthy individuals using enhanced depth imaging (EDI) of spectral-domain optical coherence tomography (SD-OCT).

Methods

A total of 158 eyes were included in the study, comprising 58 eyes of 29 patients with POAG, 50 eyes of 25 patients with PEXG, and 50 eyes of 25 healthy individuals. The lamina cribrosa thickness (LCT) (at three locations), lamina cribrosa depth (LCD), RNFL thickness, and the macular thickness were measured using the EDI mode of the SD-OCT. The results were compared among the three groups.

Results

In both POAG and PEXG groups, the LCT was significantly thinner in the center, mid-superior, and mid-inferior areas in both eyes than in the control group (p < 0.001). However, no statistically significant difference was observed between the POAG and PEXG groups in terms of LCT at all three measurement locations in both eyes (p > 0.05). The LCD was significantly lower in the control group compared to the POAG and PEXG groups (p < 0.05), but there was no significant difference between the POAG and PEXG groups (p > 0.05). The RNFL thickness was significantly lower in both the POAG and PEXG groups compared to the control group in both eyes (p < 0.05).

Conclusion

The LCT and LCD of patients with POAG and PEXG were thinner than those of healthy individuals, but there was no significant difference between the patients with POAG and PEXG.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.20
自引率
0.00%
发文量
451
期刊介绍: International Ophthalmology provides the clinician with articles on all the relevant subspecialties of ophthalmology, with a broad international scope. The emphasis is on presentation of the latest clinical research in the field. In addition, the journal includes regular sections devoted to new developments in technologies, products, and techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信