近视 LASIK/PRK 术后,后角膜测量和角膜半径比对眼内透镜配方准确性的影响。

IF 2.9 3区 医学 Q1 OPHTHALMOLOGY
Yuxing Zheng,Jiaqing Zhang,Xiaotong Han,Ruoxuan Huang,Ling Wen,Jinfeng Ye,Yiguo Huang,Xiaozhang Qiu,Xiaoyun Chen,Xuhua Tan,Lixia Luo
{"title":"近视 LASIK/PRK 术后,后角膜测量和角膜半径比对眼内透镜配方准确性的影响。","authors":"Yuxing Zheng,Jiaqing Zhang,Xiaotong Han,Ruoxuan Huang,Ling Wen,Jinfeng Ye,Yiguo Huang,Xiaozhang Qiu,Xiaoyun Chen,Xuhua Tan,Lixia Luo","doi":"10.3928/1081597x-20240718-01","DOIUrl":null,"url":null,"abstract":"PURPOSE\r\nTo investigate the impact of back-to-front corneal radius ratio (B/F ratio) and posterior keratometry (PK) on the accuracy of intraocular lens power calculation formulas in eyes after myopic laser in situ keratomileusis (LASIK)/photorefractive keratectomy (PRK) surgery.\r\n\r\nMETHODS\r\nA retrospective, consecutive case series study included 101 patients (132 eyes) with cataract after myopic LASIK/PRK. Mean prediction error (PE), mean absolute PE (MAE), median absolute error (MedAE), and the percentage of eyes within ±0.25, ±0.50, and ±1.00 diopters (D) of PE were determined.\r\n\r\nRESULTS\r\nThe Barrett True K-TK formula exhibited the lowest MAE (0.59 D) and MedAE (0.48 D) and the highest percentage of eyes within ±0.50 D of PE (54.55%) in total. In eyes with a B/F ratio of 0.70 or less and PK of -5.70 D or greater, the Potvin-Hill formula displayed the lowest MAE (0.46 to 0.67 D).\r\n\r\nCONCLUSIONS\r\nThe Barrett True-TK exhibited the highest prediction accuracy in eyes after myopic LASIK/PRK overall. However, for eyes with a low B/F ratio and flat PK, the Potvin-Hill performed best. [J Refract Surg. 2024;40(9):e635-e644.].","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"13 2 1","pages":"e635-e644"},"PeriodicalIF":2.9000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Posterior Keratometry and Corneal Radius Ratio on the Accuracy of Intraocular Lens Formulas After Myopic LASIK/PRK.\",\"authors\":\"Yuxing Zheng,Jiaqing Zhang,Xiaotong Han,Ruoxuan Huang,Ling Wen,Jinfeng Ye,Yiguo Huang,Xiaozhang Qiu,Xiaoyun Chen,Xuhua Tan,Lixia Luo\",\"doi\":\"10.3928/1081597x-20240718-01\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"PURPOSE\\r\\nTo investigate the impact of back-to-front corneal radius ratio (B/F ratio) and posterior keratometry (PK) on the accuracy of intraocular lens power calculation formulas in eyes after myopic laser in situ keratomileusis (LASIK)/photorefractive keratectomy (PRK) surgery.\\r\\n\\r\\nMETHODS\\r\\nA retrospective, consecutive case series study included 101 patients (132 eyes) with cataract after myopic LASIK/PRK. Mean prediction error (PE), mean absolute PE (MAE), median absolute error (MedAE), and the percentage of eyes within ±0.25, ±0.50, and ±1.00 diopters (D) of PE were determined.\\r\\n\\r\\nRESULTS\\r\\nThe Barrett True K-TK formula exhibited the lowest MAE (0.59 D) and MedAE (0.48 D) and the highest percentage of eyes within ±0.50 D of PE (54.55%) in total. In eyes with a B/F ratio of 0.70 or less and PK of -5.70 D or greater, the Potvin-Hill formula displayed the lowest MAE (0.46 to 0.67 D).\\r\\n\\r\\nCONCLUSIONS\\r\\nThe Barrett True-TK exhibited the highest prediction accuracy in eyes after myopic LASIK/PRK overall. However, for eyes with a low B/F ratio and flat PK, the Potvin-Hill performed best. [J Refract Surg. 2024;40(9):e635-e644.].\",\"PeriodicalId\":16951,\"journal\":{\"name\":\"Journal of refractive surgery\",\"volume\":\"13 2 1\",\"pages\":\"e635-e644\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3928/1081597x-20240718-01\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597x-20240718-01","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的研究近视激光原位角膜磨镶术(LASIK)/光屈光性角膜板层切除术(PRK)手术后,前后角膜半径比(B/F 比)和后角膜度数(PK)对眼内透镜功率计算公式准确性的影响。方法回顾性连续病例系列研究纳入了 101 名近视 LASIK/PRK 术后白内障患者(132 只眼)。结果Barrett True K-TK 公式的 MAE(0.59 D)和 MedAE(0.48 D)最低,PE 在 ±0.50 D 以内的眼睛比例最高(54.55%)。结论Barrett True-TK对近视LASIK/PRK术后眼睛的预测准确度最高。但是,对于B/F比值低、PK平坦的眼睛,Potvin-Hill表现最好。[J Refract Surg. 2024;40(9):e635-e644]。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of Posterior Keratometry and Corneal Radius Ratio on the Accuracy of Intraocular Lens Formulas After Myopic LASIK/PRK.
PURPOSE To investigate the impact of back-to-front corneal radius ratio (B/F ratio) and posterior keratometry (PK) on the accuracy of intraocular lens power calculation formulas in eyes after myopic laser in situ keratomileusis (LASIK)/photorefractive keratectomy (PRK) surgery. METHODS A retrospective, consecutive case series study included 101 patients (132 eyes) with cataract after myopic LASIK/PRK. Mean prediction error (PE), mean absolute PE (MAE), median absolute error (MedAE), and the percentage of eyes within ±0.25, ±0.50, and ±1.00 diopters (D) of PE were determined. RESULTS The Barrett True K-TK formula exhibited the lowest MAE (0.59 D) and MedAE (0.48 D) and the highest percentage of eyes within ±0.50 D of PE (54.55%) in total. In eyes with a B/F ratio of 0.70 or less and PK of -5.70 D or greater, the Potvin-Hill formula displayed the lowest MAE (0.46 to 0.67 D). CONCLUSIONS The Barrett True-TK exhibited the highest prediction accuracy in eyes after myopic LASIK/PRK overall. However, for eyes with a low B/F ratio and flat PK, the Potvin-Hill performed best. [J Refract Surg. 2024;40(9):e635-e644.].
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信