用于水中测量的压力传感器的动态响应

IF 2.3 3区 工程技术 Q2 ENGINEERING, MECHANICAL
M. Jentzsch, W. Lechner, R. Woszidlo, C. N. Nayeri, C. O. Paschereit
{"title":"用于水中测量的压力传感器的动态响应","authors":"M. Jentzsch,&nbsp;W. Lechner,&nbsp;R. Woszidlo,&nbsp;C. N. Nayeri,&nbsp;C. O. Paschereit","doi":"10.1007/s00348-024-03854-5","DOIUrl":null,"url":null,"abstract":"<div><p>Dynamic pressure measurements are indispensable in the field of fluid mechanics. Attaching tubing as a transmission line to the pressure transducer is often unavoidable but significantly reduces the usable bandwidth of the measurement system. Complex fluid-wall interactions and potential outgassing of air are present within systems with water-filled tubes. Comprehensive studies aiding researchers in selecting suitable transmission line parameters (i.e., material, length, and diameter) are not available. A simple calibration apparatus is designed for the frequency response characterization of multiple pressure transducers simultaneously applying a pressure step. The setup is thoroughly characterized and a detailed description is provided to optimize the bandwidth. A piezoresistive pressure transducer attached to water-filled tubes, as commonly used in hydrodynamic experiments, is characterized in the low-frequency range (i.e., <span>\\(f \\le {300}\\)</span> Hz). Tube-related effects, such as length, diameter, and material are investigated. The impact of entrapped air within the tubing is analyzed. The feasibility of substituting water with silicone oil to fill the tubes is explored. To optimize the usable bandwidth of the pressure measurement system for dynamic applications, it is essential to maintain short tubing that is as rigid as possible and free from entrapped air. Pressure wave propagation speed is reduced by two orders of magnitude in elastic transmission lines made of silicone. Pressure corrections through dynamic calibration are challenging due to the system’s sensitivity to various parameters affecting the dynamic response.</p></div>","PeriodicalId":554,"journal":{"name":"Experiments in Fluids","volume":"65 8","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s00348-024-03854-5.pdf","citationCount":"0","resultStr":"{\"title\":\"The dynamic response of a pressure transducer for measurements in water\",\"authors\":\"M. Jentzsch,&nbsp;W. Lechner,&nbsp;R. Woszidlo,&nbsp;C. N. Nayeri,&nbsp;C. O. Paschereit\",\"doi\":\"10.1007/s00348-024-03854-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Dynamic pressure measurements are indispensable in the field of fluid mechanics. Attaching tubing as a transmission line to the pressure transducer is often unavoidable but significantly reduces the usable bandwidth of the measurement system. Complex fluid-wall interactions and potential outgassing of air are present within systems with water-filled tubes. Comprehensive studies aiding researchers in selecting suitable transmission line parameters (i.e., material, length, and diameter) are not available. A simple calibration apparatus is designed for the frequency response characterization of multiple pressure transducers simultaneously applying a pressure step. The setup is thoroughly characterized and a detailed description is provided to optimize the bandwidth. A piezoresistive pressure transducer attached to water-filled tubes, as commonly used in hydrodynamic experiments, is characterized in the low-frequency range (i.e., <span>\\\\(f \\\\le {300}\\\\)</span> Hz). Tube-related effects, such as length, diameter, and material are investigated. The impact of entrapped air within the tubing is analyzed. The feasibility of substituting water with silicone oil to fill the tubes is explored. To optimize the usable bandwidth of the pressure measurement system for dynamic applications, it is essential to maintain short tubing that is as rigid as possible and free from entrapped air. Pressure wave propagation speed is reduced by two orders of magnitude in elastic transmission lines made of silicone. Pressure corrections through dynamic calibration are challenging due to the system’s sensitivity to various parameters affecting the dynamic response.</p></div>\",\"PeriodicalId\":554,\"journal\":{\"name\":\"Experiments in Fluids\",\"volume\":\"65 8\",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-08-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s00348-024-03854-5.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Experiments in Fluids\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s00348-024-03854-5\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Experiments in Fluids","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s00348-024-03854-5","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

摘要

动态压力测量在流体力学领域是不可或缺的。将管道作为传输线连接到压力传感器通常是不可避免的,但会大大降低测量系统的可用带宽。在充满水的管道系统中,存在着复杂的流体壁相互作用和潜在的空气放气。目前还没有全面的研究可以帮助研究人员选择合适的传输线参数(即材料、长度和直径)。本文设计了一个简单的校准装置,用于同时对多个压力传感器施加一个压力阶跃进行频率响应表征。该装置具有全面的特性,并提供了优化带宽的详细说明。在低频范围内(即 \(f\le {300}\) Hz),对连接到充水管上的压阻压力传感器进行了表征,该传感器通常用于流体力学实验。研究了与管子相关的影响,如长度、直径和材料。分析了管道内夹带空气的影响。探讨了用硅油代替水填充管道的可行性。为了优化动态应用中压力测量系统的可用带宽,必须保持短管尽可能坚硬且无夹带空气。在硅胶制成的弹性传输线中,压力波的传播速度会降低两个数量级。由于系统对影响动态响应的各种参数非常敏感,因此通过动态校准进行压力校正具有挑战性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

The dynamic response of a pressure transducer for measurements in water

The dynamic response of a pressure transducer for measurements in water

Dynamic pressure measurements are indispensable in the field of fluid mechanics. Attaching tubing as a transmission line to the pressure transducer is often unavoidable but significantly reduces the usable bandwidth of the measurement system. Complex fluid-wall interactions and potential outgassing of air are present within systems with water-filled tubes. Comprehensive studies aiding researchers in selecting suitable transmission line parameters (i.e., material, length, and diameter) are not available. A simple calibration apparatus is designed for the frequency response characterization of multiple pressure transducers simultaneously applying a pressure step. The setup is thoroughly characterized and a detailed description is provided to optimize the bandwidth. A piezoresistive pressure transducer attached to water-filled tubes, as commonly used in hydrodynamic experiments, is characterized in the low-frequency range (i.e., \(f \le {300}\) Hz). Tube-related effects, such as length, diameter, and material are investigated. The impact of entrapped air within the tubing is analyzed. The feasibility of substituting water with silicone oil to fill the tubes is explored. To optimize the usable bandwidth of the pressure measurement system for dynamic applications, it is essential to maintain short tubing that is as rigid as possible and free from entrapped air. Pressure wave propagation speed is reduced by two orders of magnitude in elastic transmission lines made of silicone. Pressure corrections through dynamic calibration are challenging due to the system’s sensitivity to various parameters affecting the dynamic response.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Experiments in Fluids
Experiments in Fluids 工程技术-工程:机械
CiteScore
5.10
自引率
12.50%
发文量
157
审稿时长
3.8 months
期刊介绍: Experiments in Fluids examines the advancement, extension, and improvement of new techniques of flow measurement. The journal also publishes contributions that employ existing experimental techniques to gain an understanding of the underlying flow physics in the areas of turbulence, aerodynamics, hydrodynamics, convective heat transfer, combustion, turbomachinery, multi-phase flows, and chemical, biological and geological flows. In addition, readers will find papers that report on investigations combining experimental and analytical/numerical approaches.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信