Lourdes Chacon Alberty,Madelyn King,Fernanda C P Mesquita,Camila Hochman-Mendez
{"title":"长期冷冻保存的人类骨衍生骨髓间充质基质细胞样本的质量评估:德克萨斯心脏研究所生物储存库和生物样本分析核心的经验。","authors":"Lourdes Chacon Alberty,Madelyn King,Fernanda C P Mesquita,Camila Hochman-Mendez","doi":"10.1089/bio.2023.0144","DOIUrl":null,"url":null,"abstract":"In biomedical research, biorepositories are pivotal resources that safeguard and supply clinical samples for scientific investigators. Proper long-term cryopreservation conditions are essential to maintain biospecimen quality. In this study, we analyzed the efficacy of sample cryopreservation at the Texas Heart Institute Biorepository and Biospecimen Profiling Core (THI-BRC). Our assessments included a thorough review of internal processes, quality reports, and both internal and external audit outcomes. We examined the integrity of human bone marrow-derived multipotent mesenchymal stromal cells (BM-MSCs) that were cryopreserved for over 5 years. These samples originated from randomly selected clinical trial participants or commercially sourced cell lines. Parameters such as cell viability, DNA and RNA integrity, population doubling time, sterility, and BM-MSC-specific attributes such as surface antigen expression and differentiation potential were studied. BM-MSC samples cryopreserved for ∼6 months served as our control. Our results demonstrated that the 5-year cryopreserved samples maintained their integrity compared with the shorter-term stored control samples. Moreover, THI-BRC has met accreditation agency standards and has not received any repeated deficiencies over 7 years. Collectively, our findings affirm that THI-BRC's biospecimen storage protocols align with accepted standards as confirmed by the quality assessment of long-term stored clinical samples.","PeriodicalId":49231,"journal":{"name":"Biopreservation and Biobanking","volume":"20 1","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quality Assessment of Long-Term Cryopreserved Human Bone-Derived Marrow Mesenchymal Stromal Cell Samples: Experience from the Texas Heart Institute Biorepository and Biospecimen Profiling Core.\",\"authors\":\"Lourdes Chacon Alberty,Madelyn King,Fernanda C P Mesquita,Camila Hochman-Mendez\",\"doi\":\"10.1089/bio.2023.0144\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In biomedical research, biorepositories are pivotal resources that safeguard and supply clinical samples for scientific investigators. Proper long-term cryopreservation conditions are essential to maintain biospecimen quality. In this study, we analyzed the efficacy of sample cryopreservation at the Texas Heart Institute Biorepository and Biospecimen Profiling Core (THI-BRC). Our assessments included a thorough review of internal processes, quality reports, and both internal and external audit outcomes. We examined the integrity of human bone marrow-derived multipotent mesenchymal stromal cells (BM-MSCs) that were cryopreserved for over 5 years. These samples originated from randomly selected clinical trial participants or commercially sourced cell lines. Parameters such as cell viability, DNA and RNA integrity, population doubling time, sterility, and BM-MSC-specific attributes such as surface antigen expression and differentiation potential were studied. BM-MSC samples cryopreserved for ∼6 months served as our control. Our results demonstrated that the 5-year cryopreserved samples maintained their integrity compared with the shorter-term stored control samples. Moreover, THI-BRC has met accreditation agency standards and has not received any repeated deficiencies over 7 years. Collectively, our findings affirm that THI-BRC's biospecimen storage protocols align with accepted standards as confirmed by the quality assessment of long-term stored clinical samples.\",\"PeriodicalId\":49231,\"journal\":{\"name\":\"Biopreservation and Biobanking\",\"volume\":\"20 1\",\"pages\":\"\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biopreservation and Biobanking\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.1089/bio.2023.0144\",\"RegionNum\":4,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CELL BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biopreservation and Biobanking","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1089/bio.2023.0144","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CELL BIOLOGY","Score":null,"Total":0}
Quality Assessment of Long-Term Cryopreserved Human Bone-Derived Marrow Mesenchymal Stromal Cell Samples: Experience from the Texas Heart Institute Biorepository and Biospecimen Profiling Core.
In biomedical research, biorepositories are pivotal resources that safeguard and supply clinical samples for scientific investigators. Proper long-term cryopreservation conditions are essential to maintain biospecimen quality. In this study, we analyzed the efficacy of sample cryopreservation at the Texas Heart Institute Biorepository and Biospecimen Profiling Core (THI-BRC). Our assessments included a thorough review of internal processes, quality reports, and both internal and external audit outcomes. We examined the integrity of human bone marrow-derived multipotent mesenchymal stromal cells (BM-MSCs) that were cryopreserved for over 5 years. These samples originated from randomly selected clinical trial participants or commercially sourced cell lines. Parameters such as cell viability, DNA and RNA integrity, population doubling time, sterility, and BM-MSC-specific attributes such as surface antigen expression and differentiation potential were studied. BM-MSC samples cryopreserved for ∼6 months served as our control. Our results demonstrated that the 5-year cryopreserved samples maintained their integrity compared with the shorter-term stored control samples. Moreover, THI-BRC has met accreditation agency standards and has not received any repeated deficiencies over 7 years. Collectively, our findings affirm that THI-BRC's biospecimen storage protocols align with accepted standards as confirmed by the quality assessment of long-term stored clinical samples.
期刊介绍:
Biopreservation and Biobanking is the first journal to provide a unifying forum for the peer-reviewed communication of recent advances in the emerging and evolving field of biospecimen procurement, processing, preservation and banking, distribution, and use. The Journal publishes a range of original articles focusing on current challenges and problems in biopreservation, and advances in methods to address these issues related to the processing of macromolecules, cells, and tissues for research.
In a new section dedicated to Emerging Markets and Technologies, the Journal highlights the emergence of new markets and technologies that are either adopting or disrupting the biobank framework as they imprint on society. The solutions presented here are anticipated to help drive innovation within the biobank community.
Biopreservation and Biobanking also explores the ethical, legal, and societal considerations surrounding biobanking and biorepository operation. Ideas and practical solutions relevant to improved quality, efficiency, and sustainability of repositories, and relating to their management, operation and oversight are discussed as well.