一种减少大气干扰的装置,用于电感耦合等离子体质谱仪的分析

IF 3.1 2区 化学 Q2 CHEMISTRY, ANALYTICAL
Xin Jiang, Yongsheng Liu, Wengui Liu, Jie Lin, Zhenyi Liu, Lifei Chen, Xi Zhu, Wen Zhang and Zhaochu Hu
{"title":"一种减少大气干扰的装置,用于电感耦合等离子体质谱仪的分析","authors":"Xin Jiang, Yongsheng Liu, Wengui Liu, Jie Lin, Zhenyi Liu, Lifei Chen, Xi Zhu, Wen Zhang and Zhaochu Hu","doi":"10.1039/D4JA00185K","DOIUrl":null,"url":null,"abstract":"<p >The atmosphere-induced interference reduction device (AIRD) shows promise in mitigating interferences in inductively coupled plasma-mass spectrometry (ICP-MS) analysis. The effectiveness of AIRD in reducing interferences caused by atmospheric gases such as H, C, N and O was evaluated by using argon (Ar) and helium (He) as shielding gases due to their inert properties. Krypton (<small><sup>82</sup></small>Kr) served as an internal standard for monitoring and correcting instrumental sensitivity drift. The shielding gas flow rate was optimized using gas dynamics simulations, revealing a threshold of 10 L min<small><sup>−1</sup></small> for optimal interference reduction. Results indicate the superiority of He in reducing interferences, with a reduction of 32% for <small><sup>12</sup></small>C<small><sup>+</sup></small>, 51% for <small><sup>15</sup></small>N<small><sup>+</sup></small>, 56% for <small><sup>16</sup></small>O<small><sup>+</sup></small>, 54% for <small><sup>16</sup></small>O<small><sup>1</sup></small>H<small><sup>1</sup></small>H<small><sup>+</sup></small>, 51% for <small><sup>40</sup></small>Ar<small><sup>14</sup></small>N<small><sup>+</sup></small>, and 42% for <small><sup>40</sup></small>Ar<small><sup>16</sup></small>O<small><sup>+</sup></small> compared to Ar. Moreover, AIRD maintained low oxide yields even after shielding gas cessation, with oxide yield maintained at approximately 0.03% for 24 hours. Analyses of LA-ICP-MS coupled with AIRD demonstrate that ThO/Th can be reduced from 0.92% to 0.15% compared to normal analysis without AIRD. Experimental investigations further revealed that AIRD influenced elemental sensitivity, particularly with He as the shielding gas, with an ∼25.7% enhancement observed in the signal intensity of <small><sup>82</sup></small>Kr.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 10","pages":" 2452-2460"},"PeriodicalIF":3.1000,"publicationDate":"2024-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A device for reducing the atmosphere-induced interferences for analysis using inductively coupled plasma-mass spectrometry†\",\"authors\":\"Xin Jiang, Yongsheng Liu, Wengui Liu, Jie Lin, Zhenyi Liu, Lifei Chen, Xi Zhu, Wen Zhang and Zhaochu Hu\",\"doi\":\"10.1039/D4JA00185K\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >The atmosphere-induced interference reduction device (AIRD) shows promise in mitigating interferences in inductively coupled plasma-mass spectrometry (ICP-MS) analysis. The effectiveness of AIRD in reducing interferences caused by atmospheric gases such as H, C, N and O was evaluated by using argon (Ar) and helium (He) as shielding gases due to their inert properties. Krypton (<small><sup>82</sup></small>Kr) served as an internal standard for monitoring and correcting instrumental sensitivity drift. The shielding gas flow rate was optimized using gas dynamics simulations, revealing a threshold of 10 L min<small><sup>−1</sup></small> for optimal interference reduction. Results indicate the superiority of He in reducing interferences, with a reduction of 32% for <small><sup>12</sup></small>C<small><sup>+</sup></small>, 51% for <small><sup>15</sup></small>N<small><sup>+</sup></small>, 56% for <small><sup>16</sup></small>O<small><sup>+</sup></small>, 54% for <small><sup>16</sup></small>O<small><sup>1</sup></small>H<small><sup>1</sup></small>H<small><sup>+</sup></small>, 51% for <small><sup>40</sup></small>Ar<small><sup>14</sup></small>N<small><sup>+</sup></small>, and 42% for <small><sup>40</sup></small>Ar<small><sup>16</sup></small>O<small><sup>+</sup></small> compared to Ar. Moreover, AIRD maintained low oxide yields even after shielding gas cessation, with oxide yield maintained at approximately 0.03% for 24 hours. Analyses of LA-ICP-MS coupled with AIRD demonstrate that ThO/Th can be reduced from 0.92% to 0.15% compared to normal analysis without AIRD. Experimental investigations further revealed that AIRD influenced elemental sensitivity, particularly with He as the shielding gas, with an ∼25.7% enhancement observed in the signal intensity of <small><sup>82</sup></small>Kr.</p>\",\"PeriodicalId\":81,\"journal\":{\"name\":\"Journal of Analytical Atomic Spectrometry\",\"volume\":\" 10\",\"pages\":\" 2452-2460\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-08-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Atomic Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2024/ja/d4ja00185k\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/ja/d4ja00185k","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

大气诱导干扰减少装置(AIRD)在减少电感耦合等离子体质谱仪(ICP-MS)分析中的干扰方面大有可为。通过使用氩气(Ar)和氦气(He)这两种惰性气体作为屏蔽气体,评估了 AIRD 在减少 H、C、N 和 O 等大气气体造成的干扰方面的有效性。氪(82Kr)作为内标,用于监测和校正仪器灵敏度漂移。利用气体动力学模拟对屏蔽气体的流速进行了优化,结果表明,10 升/分钟-1 的阈值是降低干扰的最佳值。结果表明,与氩气相比,氦气在减少干扰方面更具优势,12C+ 减少 32%,15N+ 减少 51%,16O+ 减少 56%,16O1H1H+ 减少 54%,40Ar14N+ 减少 51%,40Ar16O+ 减少 42%。此外,即使在屏蔽气体停止后,AIRD 也能保持较低的氧化物产率,氧化物产率在 24 小时内保持在约 0.03%。结合 AIRD 进行的 LA-ICP-MS 分析表明,与不使用 AIRD 的正常分析相比,ThO/Th 可从 0.92% 降低到 0.15%。实验研究进一步表明,AIRD 影响了元素灵敏度,特别是在使用 He 作为屏蔽气体时,82Kr 的信号强度提高了 25.7%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

A device for reducing the atmosphere-induced interferences for analysis using inductively coupled plasma-mass spectrometry†

A device for reducing the atmosphere-induced interferences for analysis using inductively coupled plasma-mass spectrometry†

A device for reducing the atmosphere-induced interferences for analysis using inductively coupled plasma-mass spectrometry†

The atmosphere-induced interference reduction device (AIRD) shows promise in mitigating interferences in inductively coupled plasma-mass spectrometry (ICP-MS) analysis. The effectiveness of AIRD in reducing interferences caused by atmospheric gases such as H, C, N and O was evaluated by using argon (Ar) and helium (He) as shielding gases due to their inert properties. Krypton (82Kr) served as an internal standard for monitoring and correcting instrumental sensitivity drift. The shielding gas flow rate was optimized using gas dynamics simulations, revealing a threshold of 10 L min−1 for optimal interference reduction. Results indicate the superiority of He in reducing interferences, with a reduction of 32% for 12C+, 51% for 15N+, 56% for 16O+, 54% for 16O1H1H+, 51% for 40Ar14N+, and 42% for 40Ar16O+ compared to Ar. Moreover, AIRD maintained low oxide yields even after shielding gas cessation, with oxide yield maintained at approximately 0.03% for 24 hours. Analyses of LA-ICP-MS coupled with AIRD demonstrate that ThO/Th can be reduced from 0.92% to 0.15% compared to normal analysis without AIRD. Experimental investigations further revealed that AIRD influenced elemental sensitivity, particularly with He as the shielding gas, with an ∼25.7% enhancement observed in the signal intensity of 82Kr.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信