通过 MC-ICP-MS 测定铊的同位素组成,并使用掺杂 W 纠正质量偏差

IF 3.1 2区 化学 Q2 CHEMISTRY, ANALYTICAL
Zhao-Yang Wang, Fei-Yu Dong, Lu Yin, Jun-Jie Liu, Qiao-Hui Zhong and Jie Li
{"title":"通过 MC-ICP-MS 测定铊的同位素组成,并使用掺杂 W 纠正质量偏差","authors":"Zhao-Yang Wang, Fei-Yu Dong, Lu Yin, Jun-Jie Liu, Qiao-Hui Zhong and Jie Li","doi":"10.1039/D4JA00187G","DOIUrl":null,"url":null,"abstract":"<p >Despite their widespread application in planetary and earth sciences in the past two decades, thallium isotopic compositions have been determined <em>via</em> MC-ICP-MS with instrumental mass bias corrected by employing a combination of lead doping and standard-sample bracketing. Residual Pb, either from the sample matrix or contamination, may significantly distort the isotope ratio of Pb for mass bias correction, thereby affecting the accuracy of Tl isotope measurement. In this study, we employed <small><sup>186</sup></small>W/<small><sup>184</sup></small>W (NIST SRM 3163 W) instead of <small><sup>208</sup></small>Pb/<small><sup>206</sup></small>Pb (NIST SRM 981 Pb) to correct instrumental mass bias during the measurement of Tl isotopic compositions through MC-ICP-MS. The plot of ln(<small><sup>186</sup></small>W/<small><sup>184</sup></small>W) <em>vs.</em> ln(<small><sup>205</sup></small>Tl/<small><sup>203</sup></small>Tl) shows a strong linear correlation (<em>R</em><small><sup>2</sup></small> &gt; 0.993) in the repeated analyses of NIST SRM 997 Tl using W. Two pure Tl standards, Fluka Tl and GSB Tl, produced <em>ε</em><small><sup>205</sup></small>Tl<small><sub>NIST 997</sub></small> values of −1.9 ± 0.7 (2SD, <em>n</em> = 97) and 0.8 ± 0.7 (2SD, <em>n</em> = 31), respectively. The <em>ε</em><small><sup>205</sup></small>Tl<small><sub>NIST 997</sub></small> of five geological reference materials (SCo-1, GSS-6, GSP-2, NOD-P-1, and NOD-A-1) are also reported here, and the external reproducibility of these results is better than 0.08‰ (2SD). <em>ε</em><small><sup>205</sup></small>Tl<small><sub>NIST 997</sub></small> values are in good agreement with previously published values determined using Pb doping to correct mass bias, demonstrating that W can serve as a calibrator and facilitate high-precision <em>ε</em><small><sup>205</sup></small>Tl<small><sub>NIST 997</sub></small> measurement of geological materials.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 10","pages":" 2443-2451"},"PeriodicalIF":3.1000,"publicationDate":"2024-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of thallium isotopic composition through MC-ICP-MS with mass bias corrected using admixed W†\",\"authors\":\"Zhao-Yang Wang, Fei-Yu Dong, Lu Yin, Jun-Jie Liu, Qiao-Hui Zhong and Jie Li\",\"doi\":\"10.1039/D4JA00187G\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Despite their widespread application in planetary and earth sciences in the past two decades, thallium isotopic compositions have been determined <em>via</em> MC-ICP-MS with instrumental mass bias corrected by employing a combination of lead doping and standard-sample bracketing. Residual Pb, either from the sample matrix or contamination, may significantly distort the isotope ratio of Pb for mass bias correction, thereby affecting the accuracy of Tl isotope measurement. In this study, we employed <small><sup>186</sup></small>W/<small><sup>184</sup></small>W (NIST SRM 3163 W) instead of <small><sup>208</sup></small>Pb/<small><sup>206</sup></small>Pb (NIST SRM 981 Pb) to correct instrumental mass bias during the measurement of Tl isotopic compositions through MC-ICP-MS. The plot of ln(<small><sup>186</sup></small>W/<small><sup>184</sup></small>W) <em>vs.</em> ln(<small><sup>205</sup></small>Tl/<small><sup>203</sup></small>Tl) shows a strong linear correlation (<em>R</em><small><sup>2</sup></small> &gt; 0.993) in the repeated analyses of NIST SRM 997 Tl using W. Two pure Tl standards, Fluka Tl and GSB Tl, produced <em>ε</em><small><sup>205</sup></small>Tl<small><sub>NIST 997</sub></small> values of −1.9 ± 0.7 (2SD, <em>n</em> = 97) and 0.8 ± 0.7 (2SD, <em>n</em> = 31), respectively. The <em>ε</em><small><sup>205</sup></small>Tl<small><sub>NIST 997</sub></small> of five geological reference materials (SCo-1, GSS-6, GSP-2, NOD-P-1, and NOD-A-1) are also reported here, and the external reproducibility of these results is better than 0.08‰ (2SD). <em>ε</em><small><sup>205</sup></small>Tl<small><sub>NIST 997</sub></small> values are in good agreement with previously published values determined using Pb doping to correct mass bias, demonstrating that W can serve as a calibrator and facilitate high-precision <em>ε</em><small><sup>205</sup></small>Tl<small><sub>NIST 997</sub></small> measurement of geological materials.</p>\",\"PeriodicalId\":81,\"journal\":{\"name\":\"Journal of Analytical Atomic Spectrometry\",\"volume\":\" 10\",\"pages\":\" 2443-2451\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-08-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Atomic Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2024/ja/d4ja00187g\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/ja/d4ja00187g","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

尽管铊同位素组成在过去二十年中被广泛应用于行星和地球科学领域,但铊同位素组成一直是通过 MC-ICP-MS 测定的,仪器的质量偏差校正采用铅掺杂和标准样品括弧相结合的方法。样品基质或污染中残留的铅可能会严重扭曲用于质量偏差校正的铅同位素比值,从而影响铊同位素测量的准确性。在本研究中,我们采用了 186W/184W(NIST SRM 3163 W)而不是 208Pb/206Pb(NIST SRM 981 Pb)来校正 MC-ICP-MS 测量 Tl 同位素组成时的仪器质量偏差。在使用 W 对 NIST SRM 997 Tl 进行重复分析时,ln(186W/184W)与 ln(205Tl/203Tl)的关系图显示出很强的线性相关性(R2 > 0.993)。本文还报告了五种地质参考材料(SCo-1、GSS-6、GSP-2、NOD-P-1 和 NOD-A-1)的ε205TlNIST 997 值,这些结果的外部重现性优于 0.08‰(2SD)。ε205TlNIST997值与以前发表的利用掺杂铅来校正质量偏差而测定的值非常一致,这表明W可以作为校准器,促进地质材料的高精度ε205TlNIST997测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Determination of thallium isotopic composition through MC-ICP-MS with mass bias corrected using admixed W†

Determination of thallium isotopic composition through MC-ICP-MS with mass bias corrected using admixed W†

Determination of thallium isotopic composition through MC-ICP-MS with mass bias corrected using admixed W†

Despite their widespread application in planetary and earth sciences in the past two decades, thallium isotopic compositions have been determined via MC-ICP-MS with instrumental mass bias corrected by employing a combination of lead doping and standard-sample bracketing. Residual Pb, either from the sample matrix or contamination, may significantly distort the isotope ratio of Pb for mass bias correction, thereby affecting the accuracy of Tl isotope measurement. In this study, we employed 186W/184W (NIST SRM 3163 W) instead of 208Pb/206Pb (NIST SRM 981 Pb) to correct instrumental mass bias during the measurement of Tl isotopic compositions through MC-ICP-MS. The plot of ln(186W/184W) vs. ln(205Tl/203Tl) shows a strong linear correlation (R2 > 0.993) in the repeated analyses of NIST SRM 997 Tl using W. Two pure Tl standards, Fluka Tl and GSB Tl, produced ε205TlNIST 997 values of −1.9 ± 0.7 (2SD, n = 97) and 0.8 ± 0.7 (2SD, n = 31), respectively. The ε205TlNIST 997 of five geological reference materials (SCo-1, GSS-6, GSP-2, NOD-P-1, and NOD-A-1) are also reported here, and the external reproducibility of these results is better than 0.08‰ (2SD). ε205TlNIST 997 values are in good agreement with previously published values determined using Pb doping to correct mass bias, demonstrating that W can serve as a calibrator and facilitate high-precision ε205TlNIST 997 measurement of geological materials.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信