Airin Karelys Avendaño Rondon, Maribí Isomar Terán Lozada, Izabela Batista Cordeiro, Paulo Cesar Junqueira Bandeira, Liran Levin, Priscilla Barbosa Ferreira Soares, Carlos José Soares
{"title":"使用传统和数字工作流程制作的定制义齿护齿的适应性和生物力学性能:体外应变比较分析","authors":"Airin Karelys Avendaño Rondon, Maribí Isomar Terán Lozada, Izabela Batista Cordeiro, Paulo Cesar Junqueira Bandeira, Liran Levin, Priscilla Barbosa Ferreira Soares, Carlos José Soares","doi":"10.1111/edt.12985","DOIUrl":null,"url":null,"abstract":"Background/ObjectivesThe use of different models for the fabrication of custom‐fit mouthguards (MTGs) can affect their final thickness, adaptation, and shock‐absorption properties. This study aimed to evaluate the adaptation, thickness, and shock absorption of ethylene‐vinyl acetate (EVA) thermoplastic MTGs produced using conventional plaster or three‐dimensional (3D) printed models.Materials and MethodsA typical model with simulated soft gum tissue was used as the reference model to produce MTGs with the following two different protocols: plast‐MTG using a conventional impression and plaster model (<jats:italic>n</jats:italic> = 10) and 3DPr‐MTG using a digital scanning and 3D printed model (<jats:italic>n</jats:italic> = 10). A custom‐fit MTG was fabricated using EVA sheets (Bioart) plasticized over different models. The MTG thickness (mm), internal adaptation (mm) to the typodontic model, and voids in the area (mm<jats:sup>2</jats:sup>) between the two EVA layers were measured using cone‐beam computed tomography images and Mimics software (Materialize). The shock absorption of the MTG was measured using a strain‐gauge test with a pendulum impact at 30° with a steel ball over the typodont model with and without MTGs. Data were analyzed using one‐way analysis of variance with repeated measurements, followed by Tukey's post hoc tests.ResultsThe 3DPr‐MTG showed better adaptation than that of the Plast‐MTG at the incisal/occlusal and lingual tooth surfaces (<jats:italic>p</jats:italic> < 0.001). The 3DPr‐MTG showed a thickness similar to that of the Plast‐MTG, irrespective of the measured location. MTGs produced using both model types significantly reduced the strain values during horizontal impact (3DPr‐MTG 86.2% and Plast‐MTG 87.0%) compared with the control group without MTG (<jats:italic>p</jats:italic> < 0.001).ConclusionThe MTGs showed the required standards regarding thickness, adaptation, and biomechanical performance, suggesting that the number and volume of voids had no significant impact on their functionality. Three‐dimensional printed models are a viable alternative for MTG production, providing better adaptation than the Plast‐MTG at the incisal/occlusal and lingual tooth surfaces and similar performance as the MTG produced with the conventional protocol.","PeriodicalId":55180,"journal":{"name":"Dental Traumatology","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Adaptation and Biomechanical Performance of Custom‐Fit Mouthguards Produced Using Conventional and Digital Workflows: A Comparative In Vitro Strain Analysis\",\"authors\":\"Airin Karelys Avendaño Rondon, Maribí Isomar Terán Lozada, Izabela Batista Cordeiro, Paulo Cesar Junqueira Bandeira, Liran Levin, Priscilla Barbosa Ferreira Soares, Carlos José Soares\",\"doi\":\"10.1111/edt.12985\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background/ObjectivesThe use of different models for the fabrication of custom‐fit mouthguards (MTGs) can affect their final thickness, adaptation, and shock‐absorption properties. This study aimed to evaluate the adaptation, thickness, and shock absorption of ethylene‐vinyl acetate (EVA) thermoplastic MTGs produced using conventional plaster or three‐dimensional (3D) printed models.Materials and MethodsA typical model with simulated soft gum tissue was used as the reference model to produce MTGs with the following two different protocols: plast‐MTG using a conventional impression and plaster model (<jats:italic>n</jats:italic> = 10) and 3DPr‐MTG using a digital scanning and 3D printed model (<jats:italic>n</jats:italic> = 10). A custom‐fit MTG was fabricated using EVA sheets (Bioart) plasticized over different models. The MTG thickness (mm), internal adaptation (mm) to the typodontic model, and voids in the area (mm<jats:sup>2</jats:sup>) between the two EVA layers were measured using cone‐beam computed tomography images and Mimics software (Materialize). The shock absorption of the MTG was measured using a strain‐gauge test with a pendulum impact at 30° with a steel ball over the typodont model with and without MTGs. Data were analyzed using one‐way analysis of variance with repeated measurements, followed by Tukey's post hoc tests.ResultsThe 3DPr‐MTG showed better adaptation than that of the Plast‐MTG at the incisal/occlusal and lingual tooth surfaces (<jats:italic>p</jats:italic> < 0.001). The 3DPr‐MTG showed a thickness similar to that of the Plast‐MTG, irrespective of the measured location. MTGs produced using both model types significantly reduced the strain values during horizontal impact (3DPr‐MTG 86.2% and Plast‐MTG 87.0%) compared with the control group without MTG (<jats:italic>p</jats:italic> < 0.001).ConclusionThe MTGs showed the required standards regarding thickness, adaptation, and biomechanical performance, suggesting that the number and volume of voids had no significant impact on their functionality. Three‐dimensional printed models are a viable alternative for MTG production, providing better adaptation than the Plast‐MTG at the incisal/occlusal and lingual tooth surfaces and similar performance as the MTG produced with the conventional protocol.\",\"PeriodicalId\":55180,\"journal\":{\"name\":\"Dental Traumatology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-09-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dental Traumatology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/edt.12985\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Traumatology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/edt.12985","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Adaptation and Biomechanical Performance of Custom‐Fit Mouthguards Produced Using Conventional and Digital Workflows: A Comparative In Vitro Strain Analysis
Background/ObjectivesThe use of different models for the fabrication of custom‐fit mouthguards (MTGs) can affect their final thickness, adaptation, and shock‐absorption properties. This study aimed to evaluate the adaptation, thickness, and shock absorption of ethylene‐vinyl acetate (EVA) thermoplastic MTGs produced using conventional plaster or three‐dimensional (3D) printed models.Materials and MethodsA typical model with simulated soft gum tissue was used as the reference model to produce MTGs with the following two different protocols: plast‐MTG using a conventional impression and plaster model (n = 10) and 3DPr‐MTG using a digital scanning and 3D printed model (n = 10). A custom‐fit MTG was fabricated using EVA sheets (Bioart) plasticized over different models. The MTG thickness (mm), internal adaptation (mm) to the typodontic model, and voids in the area (mm2) between the two EVA layers were measured using cone‐beam computed tomography images and Mimics software (Materialize). The shock absorption of the MTG was measured using a strain‐gauge test with a pendulum impact at 30° with a steel ball over the typodont model with and without MTGs. Data were analyzed using one‐way analysis of variance with repeated measurements, followed by Tukey's post hoc tests.ResultsThe 3DPr‐MTG showed better adaptation than that of the Plast‐MTG at the incisal/occlusal and lingual tooth surfaces (p < 0.001). The 3DPr‐MTG showed a thickness similar to that of the Plast‐MTG, irrespective of the measured location. MTGs produced using both model types significantly reduced the strain values during horizontal impact (3DPr‐MTG 86.2% and Plast‐MTG 87.0%) compared with the control group without MTG (p < 0.001).ConclusionThe MTGs showed the required standards regarding thickness, adaptation, and biomechanical performance, suggesting that the number and volume of voids had no significant impact on their functionality. Three‐dimensional printed models are a viable alternative for MTG production, providing better adaptation than the Plast‐MTG at the incisal/occlusal and lingual tooth surfaces and similar performance as the MTG produced with the conventional protocol.
期刊介绍:
Dental Traumatology is an international journal that aims to convey scientific and clinical progress in all areas related to adult and pediatric dental traumatology. This includes the following topics:
- Epidemiology, Social Aspects, Education, Diagnostics
- Esthetics / Prosthetics/ Restorative
- Evidence Based Traumatology & Study Design
- Oral & Maxillofacial Surgery/Transplant/Implant
- Pediatrics and Orthodontics
- Prevention and Sports Dentistry
- Endodontics and Periodontal Aspects
The journal"s aim is to promote communication among clinicians, educators, researchers, and others interested in the field of dental traumatology.