质子和碳离子微束疗法:从建模到治疗

IF 0.6 4区 物理与天体物理 Q4 PHYSICS, PARTICLES & FIELDS
I. A. Pshenichnov, U. A. Dmitrieva, S. D. Savenkov, A. O. Svetlichnyi
{"title":"质子和碳离子微束疗法:从建模到治疗","authors":"I. A. Pshenichnov,&nbsp;U. A. Dmitrieva,&nbsp;S. D. Savenkov,&nbsp;A. O. Svetlichnyi","doi":"10.1134/S1063779624700606","DOIUrl":null,"url":null,"abstract":"<p>Arrays of minibeams of protons and <sup>12</sup>C in tissue-like media were modeled with Geant4 toolkit. A set of beam energies was used in simulations to provide a Spead-out Bragg peak (SOBP) extended by 6 cm in depth for protons as well as for <sup>12</sup>C. In both cases, beams of 0.3 or 0.5 mm FWHM were arranged at the entrance to a water phantom either on a rectangular or an hexagonal grid to compare two kinds of projectiles and different minibeam patterns. Differential and cumulative dose-volume histograms (DVH) were calculated and compared for protons and <sup>12</sup>C as dose uniformity metrics. A uniform dose distribution was easily achieved with protons due to an enhanced lateral scattering of these projectiles in comparison to <sup>12</sup>C. The cumulative DVHs calculated for 0.3 or 0.5 mm minibeams almost coincide in the target volume, but diverge for different grid patterns. In contrast, cumulative entry DVHs were found similar for both grid patterns, but different for 0.3 and 0.5 mm minibeams.</p>","PeriodicalId":729,"journal":{"name":"Physics of Particles and Nuclei","volume":null,"pages":null},"PeriodicalIF":0.6000,"publicationDate":"2024-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Proton and Carbon-Ion Minibeam Therapy: From Modeling to Treatment\",\"authors\":\"I. A. Pshenichnov,&nbsp;U. A. Dmitrieva,&nbsp;S. D. Savenkov,&nbsp;A. O. Svetlichnyi\",\"doi\":\"10.1134/S1063779624700606\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Arrays of minibeams of protons and <sup>12</sup>C in tissue-like media were modeled with Geant4 toolkit. A set of beam energies was used in simulations to provide a Spead-out Bragg peak (SOBP) extended by 6 cm in depth for protons as well as for <sup>12</sup>C. In both cases, beams of 0.3 or 0.5 mm FWHM were arranged at the entrance to a water phantom either on a rectangular or an hexagonal grid to compare two kinds of projectiles and different minibeam patterns. Differential and cumulative dose-volume histograms (DVH) were calculated and compared for protons and <sup>12</sup>C as dose uniformity metrics. A uniform dose distribution was easily achieved with protons due to an enhanced lateral scattering of these projectiles in comparison to <sup>12</sup>C. The cumulative DVHs calculated for 0.3 or 0.5 mm minibeams almost coincide in the target volume, but diverge for different grid patterns. In contrast, cumulative entry DVHs were found similar for both grid patterns, but different for 0.3 and 0.5 mm minibeams.</p>\",\"PeriodicalId\":729,\"journal\":{\"name\":\"Physics of Particles and Nuclei\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2024-08-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physics of Particles and Nuclei\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://link.springer.com/article/10.1134/S1063779624700606\",\"RegionNum\":4,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHYSICS, PARTICLES & FIELDS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics of Particles and Nuclei","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1134/S1063779624700606","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, PARTICLES & FIELDS","Score":null,"Total":0}
引用次数: 0

摘要

摘要 利用 Geant4 工具包对组织样介质中的质子和 12C 微型光束阵列进行了建模。模拟中使用了一组光束能量,为质子和 12C 提供了一个延伸 6 厘米深度的 Spead-out Bragg 峰 (SOBP)。在这两种情况下,0.3 或 0.5 mm FWHM 的射束都被安排在矩形或六边形网格的水模型入口处,以比较两种射弹和不同的微型光束模式。计算并比较了质子和 12C 的差分和累积剂量体积直方图(DVH)作为剂量均匀性指标。由于质子射弹的横向散射比 12C 射弹强,因此质子射弹很容易实现剂量均匀分布。为 0.3 毫米或 0.5 毫米微型光束计算出的累积 DVH 在靶体积内几乎重合,但在不同的网格模式下会出现分歧。与此相反,两种网格模式下的累积进入 DVH 值相似,但 0.3 毫米和 0.5 毫米微光束的累积进入 DVH 值不同。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Proton and Carbon-Ion Minibeam Therapy: From Modeling to Treatment

Proton and Carbon-Ion Minibeam Therapy: From Modeling to Treatment

Proton and Carbon-Ion Minibeam Therapy: From Modeling to Treatment

Arrays of minibeams of protons and 12C in tissue-like media were modeled with Geant4 toolkit. A set of beam energies was used in simulations to provide a Spead-out Bragg peak (SOBP) extended by 6 cm in depth for protons as well as for 12C. In both cases, beams of 0.3 or 0.5 mm FWHM were arranged at the entrance to a water phantom either on a rectangular or an hexagonal grid to compare two kinds of projectiles and different minibeam patterns. Differential and cumulative dose-volume histograms (DVH) were calculated and compared for protons and 12C as dose uniformity metrics. A uniform dose distribution was easily achieved with protons due to an enhanced lateral scattering of these projectiles in comparison to 12C. The cumulative DVHs calculated for 0.3 or 0.5 mm minibeams almost coincide in the target volume, but diverge for different grid patterns. In contrast, cumulative entry DVHs were found similar for both grid patterns, but different for 0.3 and 0.5 mm minibeams.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Physics of Particles and Nuclei
Physics of Particles and Nuclei 物理-物理:粒子与场物理
CiteScore
1.00
自引率
0.00%
发文量
116
审稿时长
6-12 weeks
期刊介绍: The journal Fizika Elementarnykh Chastits i Atomnogo Yadr of the Joint Institute for Nuclear Research (JINR, Dubna) was founded by Academician N.N. Bogolyubov in August 1969. The Editors-in-chief of the journal were Academician N.N. Bogolyubov (1970–1992) and Academician A.M. Baldin (1992–2001). Its English translation, Physics of Particles and Nuclei, appears simultaneously with the original Russian-language edition. Published by leading physicists from the JINR member states, as well as by scientists from other countries, review articles in this journal examine problems of elementary particle physics, nuclear physics, condensed matter physics, experimental data processing, accelerators and related instrumentation ecology and radiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信