虹膜囊张力环对长轴向长度患者人工晶体-囊复合体的影响:基于 SS-OCT 的临床观察。

IF 2.9 3区 医学 Q1 OPHTHALMOLOGY
Pingjun Chang,Yiwen Hu,Xueer Wu,Shuyi Qian,Yuanyuan Li,Yiyi Wang,Fuman Yang,Yune Zhao
{"title":"虹膜囊张力环对长轴向长度患者人工晶体-囊复合体的影响:基于 SS-OCT 的临床观察。","authors":"Pingjun Chang,Yiwen Hu,Xueer Wu,Shuyi Qian,Yuanyuan Li,Yiyi Wang,Fuman Yang,Yune Zhao","doi":"10.3928/1081597x-20240723-02","DOIUrl":null,"url":null,"abstract":"PURPOSE\r\nTo evaluate the influence of a capsular tension ring (CTR) on the intraocular lens (IOL)-capsule complex after cataract surgery in patients with long axial length.\r\n\r\nMETHODS\r\nThis was a prospective study. Patients underwent phacoemulsification and IOL implantation, with or without CTR implantation. Swept-source optical coherence tomography was performed at 1 day, 1 week, 1 month, and 3 months postoperatively to determine the postoperative aqueous depth (PAD), capsular bend index (CBI), and IOL tilt and decentration. Spherical equivalent values were obtained through subjective refraction and autorefraction. Root mean square was adopted to evaluate the indices listed above.\r\n\r\nRESULTS\r\nForty-three patients (56 eyes) were included in the study. Generalized estimating equation analysis of PAD showed a statistical difference between groups (P = .031). The RMS of the change in PAD was smaller in the CTR group than in the non-CTR group during the 3 months after surgery (P = .015). CBI in the CTR group increased more from 1 to 3 months after surgery than that in the non-CTR group (P = .025). The RMS of the change in vertical decentration was smaller in the CTR group than in the non-CTR group during the 3-month follow-up (P = .009).\r\n\r\nCONCLUSIONS\r\nCTR implantation can stabilize the axial position of the IOL within the capsular bag after cataract surgery in patients with long axial length without affecting the refractive stability. The formation of capsular bend may be slightly delayed in the early stage after CTR implantation, but it accelerates from 1 to 3 months after surgery. [J Refract Surg. 2024;40(9):e654-e661.].","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"48 1","pages":"e654-e661"},"PeriodicalIF":2.9000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of Capsular Tension Rings on the IOL-Capsule Complex in Patients With Long Axial Length: A Clinical Observation Based on SS-OCT.\",\"authors\":\"Pingjun Chang,Yiwen Hu,Xueer Wu,Shuyi Qian,Yuanyuan Li,Yiyi Wang,Fuman Yang,Yune Zhao\",\"doi\":\"10.3928/1081597x-20240723-02\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"PURPOSE\\r\\nTo evaluate the influence of a capsular tension ring (CTR) on the intraocular lens (IOL)-capsule complex after cataract surgery in patients with long axial length.\\r\\n\\r\\nMETHODS\\r\\nThis was a prospective study. Patients underwent phacoemulsification and IOL implantation, with or without CTR implantation. Swept-source optical coherence tomography was performed at 1 day, 1 week, 1 month, and 3 months postoperatively to determine the postoperative aqueous depth (PAD), capsular bend index (CBI), and IOL tilt and decentration. Spherical equivalent values were obtained through subjective refraction and autorefraction. Root mean square was adopted to evaluate the indices listed above.\\r\\n\\r\\nRESULTS\\r\\nForty-three patients (56 eyes) were included in the study. Generalized estimating equation analysis of PAD showed a statistical difference between groups (P = .031). The RMS of the change in PAD was smaller in the CTR group than in the non-CTR group during the 3 months after surgery (P = .015). CBI in the CTR group increased more from 1 to 3 months after surgery than that in the non-CTR group (P = .025). The RMS of the change in vertical decentration was smaller in the CTR group than in the non-CTR group during the 3-month follow-up (P = .009).\\r\\n\\r\\nCONCLUSIONS\\r\\nCTR implantation can stabilize the axial position of the IOL within the capsular bag after cataract surgery in patients with long axial length without affecting the refractive stability. The formation of capsular bend may be slightly delayed in the early stage after CTR implantation, but it accelerates from 1 to 3 months after surgery. [J Refract Surg. 2024;40(9):e654-e661.].\",\"PeriodicalId\":16951,\"journal\":{\"name\":\"Journal of refractive surgery\",\"volume\":\"48 1\",\"pages\":\"e654-e661\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3928/1081597x-20240723-02\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597x-20240723-02","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的评估长轴患者白内障手术后囊膜张力环(CTR)对人工晶体-囊膜复合体的影响。方法这是一项前瞻性研究。患者接受了超声乳化手术和人工晶体植入术,无论是否植入了 CTR。分别在术后 1 天、1 周、1 个月和 3 个月进行扫源光学相干断层扫描,以确定术后水深(PAD)、囊膜弯曲指数(CBI)以及人工晶体倾斜度和分散度。球面等值通过主观屈光度和自动屈光度获得。采用均方根法评估上述指数。PAD 的广义估计方程分析表明,组间存在统计学差异(P = .031)。术后 3 个月内,CTR 组 PAD 变化的均方根小于非 CTR 组(P = .015)。术后 1 至 3 个月,CTR 组的 CBI 增幅高于非 CTR 组(P = .025)。结论CTR植入术可以在不影响屈光稳定性的情况下,稳定长轴患者白内障手术后人工晶体在囊袋内的轴向位置。在 CTR 植入术后的早期阶段,囊袋弯曲的形成可能会稍有延迟,但在术后 1 到 3 个月后会加快。[J Refract Surg. 2024;40(9):e654-e661]。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of Capsular Tension Rings on the IOL-Capsule Complex in Patients With Long Axial Length: A Clinical Observation Based on SS-OCT.
PURPOSE To evaluate the influence of a capsular tension ring (CTR) on the intraocular lens (IOL)-capsule complex after cataract surgery in patients with long axial length. METHODS This was a prospective study. Patients underwent phacoemulsification and IOL implantation, with or without CTR implantation. Swept-source optical coherence tomography was performed at 1 day, 1 week, 1 month, and 3 months postoperatively to determine the postoperative aqueous depth (PAD), capsular bend index (CBI), and IOL tilt and decentration. Spherical equivalent values were obtained through subjective refraction and autorefraction. Root mean square was adopted to evaluate the indices listed above. RESULTS Forty-three patients (56 eyes) were included in the study. Generalized estimating equation analysis of PAD showed a statistical difference between groups (P = .031). The RMS of the change in PAD was smaller in the CTR group than in the non-CTR group during the 3 months after surgery (P = .015). CBI in the CTR group increased more from 1 to 3 months after surgery than that in the non-CTR group (P = .025). The RMS of the change in vertical decentration was smaller in the CTR group than in the non-CTR group during the 3-month follow-up (P = .009). CONCLUSIONS CTR implantation can stabilize the axial position of the IOL within the capsular bag after cataract surgery in patients with long axial length without affecting the refractive stability. The formation of capsular bend may be slightly delayed in the early stage after CTR implantation, but it accelerates from 1 to 3 months after surgery. [J Refract Surg. 2024;40(9):e654-e661.].
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信