{"title":"基于阻抗法的配电网单相接地故障定位技术研究","authors":"Sha Wang, Shengkai Wei","doi":"10.1063/5.0225951","DOIUrl":null,"url":null,"abstract":"This article mainly introduces the impedance based single-phase grounding fault location method for distribution networks, including its theoretical basis, algorithm steps, and simulation verification. First, starting from the impedance analysis of the transmission line model, the method of accurately measuring the location of the fault point through phase domain analysis is explained. Next, the process of impedance analysis for single-phase grounding faults was described in detail, that is, how to solve the impedance of the grounding fault points by calculating the voltage and current signals. Then, the specific process of the impedance based grounding fault location algorithm was introduced, including the calculation of equivalent load impedance, the calculation of starting voltage and current, the calculation of grounding current, and the solution of fault point location. Finally, simulation verification was conducted using an IEEE 34 node distribution system example in a MATLAB/Simulink environment, and the results showed that the algorithm has high positioning accuracy, with a maximum error of within 3%.","PeriodicalId":7619,"journal":{"name":"AIP Advances","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on single-phase grounding fault location technology in distribution networks based on impedance method\",\"authors\":\"Sha Wang, Shengkai Wei\",\"doi\":\"10.1063/5.0225951\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article mainly introduces the impedance based single-phase grounding fault location method for distribution networks, including its theoretical basis, algorithm steps, and simulation verification. First, starting from the impedance analysis of the transmission line model, the method of accurately measuring the location of the fault point through phase domain analysis is explained. Next, the process of impedance analysis for single-phase grounding faults was described in detail, that is, how to solve the impedance of the grounding fault points by calculating the voltage and current signals. Then, the specific process of the impedance based grounding fault location algorithm was introduced, including the calculation of equivalent load impedance, the calculation of starting voltage and current, the calculation of grounding current, and the solution of fault point location. Finally, simulation verification was conducted using an IEEE 34 node distribution system example in a MATLAB/Simulink environment, and the results showed that the algorithm has high positioning accuracy, with a maximum error of within 3%.\",\"PeriodicalId\":7619,\"journal\":{\"name\":\"AIP Advances\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"AIP Advances\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0225951\",\"RegionNum\":4,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MATERIALS SCIENCE, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"AIP Advances","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1063/5.0225951","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
Research on single-phase grounding fault location technology in distribution networks based on impedance method
This article mainly introduces the impedance based single-phase grounding fault location method for distribution networks, including its theoretical basis, algorithm steps, and simulation verification. First, starting from the impedance analysis of the transmission line model, the method of accurately measuring the location of the fault point through phase domain analysis is explained. Next, the process of impedance analysis for single-phase grounding faults was described in detail, that is, how to solve the impedance of the grounding fault points by calculating the voltage and current signals. Then, the specific process of the impedance based grounding fault location algorithm was introduced, including the calculation of equivalent load impedance, the calculation of starting voltage and current, the calculation of grounding current, and the solution of fault point location. Finally, simulation verification was conducted using an IEEE 34 node distribution system example in a MATLAB/Simulink environment, and the results showed that the algorithm has high positioning accuracy, with a maximum error of within 3%.
期刊介绍:
AIP Advances is an open access journal publishing in all areas of physical sciences—applied, theoretical, and experimental. All published articles are freely available to read, download, and share. The journal prides itself on the belief that all good science is important and relevant. Our inclusive scope and publication standards make it an essential outlet for scientists in the physical sciences.
AIP Advances is a community-based journal, with a fast production cycle. The quick publication process and open-access model allows us to quickly distribute new scientific concepts. Our Editors, assisted by peer review, determine whether a manuscript is technically correct and original. After publication, the readership evaluates whether a manuscript is timely, relevant, or significant.