{"title":"静水压对有创冠状动脉压力测量的影响:与[15O]H2O-正电子发射断层扫描血流数据的比较","authors":"Adriaan Wilgenhof MD,&nbsp;Ruurt A. Jukema MD,&nbsp;Roel S. Driessen MD, PhD,&nbsp;Ibrahim Danad MD, PhD,&nbsp;Pieter G. Raijmakers MD, PhD,&nbsp;Niels van Royen MD, PhD,&nbsp;Lokien X. van Nunen MD, PhD,&nbsp;Carlos Collet MD, PhD,&nbsp;Guus A. de Waard MD, PhD,&nbsp;Paul Knaapen MD, PhD","doi":"10.1002/ccd.31215","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Fractional flow reserve (FFR) has emerged as the invasive gold standard for assessing vessel-specific ischemia. However, FFR measurements are influenced by the hydrostatic effect, which might adversely impact the assessment of ischemia.</p>\n </section>\n \n <section>\n \n <h3> Aims</h3>\n \n <p>This study aimed to investigate the impact of hydrostatic pressure on FFR measurements by correcting for the height and comparing FFR with [<sup>15</sup>O]H<sub>2</sub>O positron emission tomography (PET)-derived relative flow reserve (RFR).</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>The 206 patients were included in this analysis. Patients underwent coronary computed tomography angiography (CCTA), [<sup>15</sup>O]H<sub>2</sub>O PET, and invasive coronary angiography with routine FFR in every epicardial artery. Height differences between the aortic guiding catheter and distal pressure sensor were quantified on CCTA images. An FFR ≤ 0.80 was considered significant.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The study found a reclassification in 7% of the coronary arteries. Notably, 11% of left anterior descending (LAD) arteries were reclassified from hemodynamically significant to nonsignificant. Conversely, 6% of left circumflex (Cx) arteries were reclassified from nonsignificant to significant. After correcting for the hydrostatic pressure effect, the correlation between FFR and PET-derived RFR increased significantly from <i>r</i> = 0.720 to <i>r</i> = 0.786 (<i>p</i> = 0.009). The average magnitude of correction was +0.05 FFR units in the LAD, −0.03 in the Cx, and −0.02 in the right coronary artery.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>Hydrostatic pressure has a small but clinically relevant influence on FFR measurements obtained with a pressure wire. Correcting for this hydrostatic error significantly enhances the correlation between FFR and PET-derived RFR.</p>\n </section>\n </div>","PeriodicalId":9650,"journal":{"name":"Catheterization and Cardiovascular Interventions","volume":"104 5","pages":"980-989"},"PeriodicalIF":2.1000,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/ccd.31215","citationCount":"0","resultStr":"{\"title\":\"The effect of hydrostatic pressure on invasive coronary pressure measurements: Comparison with [15O]H2O-positron emission tomography flow data\",\"authors\":\"Adriaan Wilgenhof MD,&nbsp;Ruurt A. Jukema MD,&nbsp;Roel S. Driessen MD, PhD,&nbsp;Ibrahim Danad MD, PhD,&nbsp;Pieter G. Raijmakers MD, PhD,&nbsp;Niels van Royen MD, PhD,&nbsp;Lokien X. van Nunen MD, PhD,&nbsp;Carlos Collet MD, PhD,&nbsp;Guus A. de Waard MD, PhD,&nbsp;Paul Knaapen MD, PhD\",\"doi\":\"10.1002/ccd.31215\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>Fractional flow reserve (FFR) has emerged as the invasive gold standard for assessing vessel-specific ischemia. However, FFR measurements are influenced by the hydrostatic effect, which might adversely impact the assessment of ischemia.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Aims</h3>\\n \\n <p>This study aimed to investigate the impact of hydrostatic pressure on FFR measurements by correcting for the height and comparing FFR with [<sup>15</sup>O]H<sub>2</sub>O positron emission tomography (PET)-derived relative flow reserve (RFR).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>The 206 patients were included in this analysis. Patients underwent coronary computed tomography angiography (CCTA), [<sup>15</sup>O]H<sub>2</sub>O PET, and invasive coronary angiography with routine FFR in every epicardial artery. Height differences between the aortic guiding catheter and distal pressure sensor were quantified on CCTA images. An FFR ≤ 0.80 was considered significant.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>The study found a reclassification in 7% of the coronary arteries. Notably, 11% of left anterior descending (LAD) arteries were reclassified from hemodynamically significant to nonsignificant. Conversely, 6% of left circumflex (Cx) arteries were reclassified from nonsignificant to significant. After correcting for the hydrostatic pressure effect, the correlation between FFR and PET-derived RFR increased significantly from <i>r</i> = 0.720 to <i>r</i> = 0.786 (<i>p</i> = 0.009). The average magnitude of correction was +0.05 FFR units in the LAD, −0.03 in the Cx, and −0.02 in the right coronary artery.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>Hydrostatic pressure has a small but clinically relevant influence on FFR measurements obtained with a pressure wire. Correcting for this hydrostatic error significantly enhances the correlation between FFR and PET-derived RFR.</p>\\n </section>\\n </div>\",\"PeriodicalId\":9650,\"journal\":{\"name\":\"Catheterization and Cardiovascular Interventions\",\"volume\":\"104 5\",\"pages\":\"980-989\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-09-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/ccd.31215\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Catheterization and Cardiovascular Interventions\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/ccd.31215\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Catheterization and Cardiovascular Interventions","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ccd.31215","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景部分血流储备(FFR)已成为评估血管特异性缺血的有创金标准。本研究旨在通过校正高度来调查静水压对 FFR 测量的影响,并将 FFR 与[15O]H2O 正电子发射断层扫描(PET)得出的相对血流储备(RFR)进行比较。患者接受了冠状动脉计算机断层扫描(CCTA)、[15O]H2O PET 和有创冠状动脉造影术,并对每条心外膜动脉进行了常规 FFR 检查。在 CCTA 图像上量化了主动脉导引导管和远端压力传感器之间的高度差。研究发现,7% 的冠状动脉被重新分类。值得注意的是,11%的左前降支(LAD)动脉从血流动力学显著性重新分类为非显著性。相反,6% 的左侧环曲(Cx)动脉从非显著性重新分类为显著性。校正静水压效应后,FFR 和 PET 导出 RFR 之间的相关性从 r = 0.720 显著增加到 r = 0.786(p = 0.009)。结论静水压力对使用压力导线获得的 FFR 测量值的影响很小,但与临床相关。对这一静水压误差进行校正可显著增强 FFR 与 PET 导出的 RFR 之间的相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

The effect of hydrostatic pressure on invasive coronary pressure measurements: Comparison with [15O]H2O-positron emission tomography flow data

The effect of hydrostatic pressure on invasive coronary pressure measurements: Comparison with [15O]H2O-positron emission tomography flow data

Background

Fractional flow reserve (FFR) has emerged as the invasive gold standard for assessing vessel-specific ischemia. However, FFR measurements are influenced by the hydrostatic effect, which might adversely impact the assessment of ischemia.

Aims

This study aimed to investigate the impact of hydrostatic pressure on FFR measurements by correcting for the height and comparing FFR with [15O]H2O positron emission tomography (PET)-derived relative flow reserve (RFR).

Methods

The 206 patients were included in this analysis. Patients underwent coronary computed tomography angiography (CCTA), [15O]H2O PET, and invasive coronary angiography with routine FFR in every epicardial artery. Height differences between the aortic guiding catheter and distal pressure sensor were quantified on CCTA images. An FFR ≤ 0.80 was considered significant.

Results

The study found a reclassification in 7% of the coronary arteries. Notably, 11% of left anterior descending (LAD) arteries were reclassified from hemodynamically significant to nonsignificant. Conversely, 6% of left circumflex (Cx) arteries were reclassified from nonsignificant to significant. After correcting for the hydrostatic pressure effect, the correlation between FFR and PET-derived RFR increased significantly from r = 0.720 to r = 0.786 (p = 0.009). The average magnitude of correction was +0.05 FFR units in the LAD, −0.03 in the Cx, and −0.02 in the right coronary artery.

Conclusion

Hydrostatic pressure has a small but clinically relevant influence on FFR measurements obtained with a pressure wire. Correcting for this hydrostatic error significantly enhances the correlation between FFR and PET-derived RFR.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.40
自引率
8.70%
发文量
419
审稿时长
2 months
期刊介绍: Catheterization and Cardiovascular Interventions is an international journal covering the broad field of cardiovascular diseases. Subject material includes basic and clinical information that is derived from or related to invasive and interventional coronary or peripheral vascular techniques. The journal focuses on material that will be of immediate practical value to physicians providing patient care in the clinical laboratory setting. To accomplish this, the journal publishes Preliminary Reports and Work In Progress articles that complement the traditional Original Studies, Case Reports, and Comprehensive Reviews. Perspective and insight concerning controversial subjects and evolving technologies are provided regularly through Editorial Commentaries furnished by members of the Editorial Board and other experts. Articles are subject to double-blind peer review and complete editorial evaluation prior to any decision regarding acceptability.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信