{"title":"研究寒冷气候条件下使用电阻加热器的铁路道岔热量分布","authors":"Arefeh Lotfi, Adeel Yousuf, Muhammad Shakeel Virk","doi":"10.3390/app14188151","DOIUrl":null,"url":null,"abstract":"The railway is an essential source of logistics and transportation in cold regions, but low temperatures and icing can be challenging for uninterrupted railway operations in these regions. Icing on railway switches is a safety hazard, and presently, one of the industry’s adaptive approaches for ice mitigation is the use of resistive heaters. This method is efficient but consumes a great amount of electricity, leading to high financial costs in terms of the operation and maintenance of railway tracks in ice-prone regions. In this paper, a study is carried out using experiments and computational simulations to analyze the heat distribution in a cross-section of a rail at below-freezing temperatures. Experiments are performed in a cold room using an actual rail switch, thermocouples, and infrared imaging, while numerical analyses are carried out using a MATLAB-based analytical model to simulate the heat transfer, considering a section of stock rail and a heating element. Results show a considerable loss of heat from the heater to the surroundings of the rail, especially towards the ground ballast. Numerical simulation results provide a good insight into heat transfer along railway sections, and results are validated with experiments, where a good agreement is found. This study provides a good base for further optimization of resistive heating operations for ice mitigation along railway switches.","PeriodicalId":8224,"journal":{"name":"Applied Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study of Heat Distribution in Railway Switch Using Resistive Heater in Cold Climate Conditions\",\"authors\":\"Arefeh Lotfi, Adeel Yousuf, Muhammad Shakeel Virk\",\"doi\":\"10.3390/app14188151\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The railway is an essential source of logistics and transportation in cold regions, but low temperatures and icing can be challenging for uninterrupted railway operations in these regions. Icing on railway switches is a safety hazard, and presently, one of the industry’s adaptive approaches for ice mitigation is the use of resistive heaters. This method is efficient but consumes a great amount of electricity, leading to high financial costs in terms of the operation and maintenance of railway tracks in ice-prone regions. In this paper, a study is carried out using experiments and computational simulations to analyze the heat distribution in a cross-section of a rail at below-freezing temperatures. Experiments are performed in a cold room using an actual rail switch, thermocouples, and infrared imaging, while numerical analyses are carried out using a MATLAB-based analytical model to simulate the heat transfer, considering a section of stock rail and a heating element. Results show a considerable loss of heat from the heater to the surroundings of the rail, especially towards the ground ballast. Numerical simulation results provide a good insight into heat transfer along railway sections, and results are validated with experiments, where a good agreement is found. This study provides a good base for further optimization of resistive heating operations for ice mitigation along railway switches.\",\"PeriodicalId\":8224,\"journal\":{\"name\":\"Applied Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/app14188151\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Mathematics\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/app14188151","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Mathematics","Score":null,"Total":0}
引用次数: 0

摘要

铁路是寒冷地区物流和运输的重要来源,但低温和结冰对这些地区的不间断铁路运营构成挑战。铁路道岔结冰是一种安全隐患,目前,行业内缓解结冰的适应性方法之一是使用电阻加热器。这种方法效率高,但耗电量大,导致易结冰地区铁路运行和维护的经济成本高昂。本文通过实验和计算模拟来分析冰点以下温度下铁轨横截面的热量分布。实验在冷室中进行,使用了实际的钢轨开关、热电偶和红外成像,而数值分析则使用基于 MATLAB 的分析模型来模拟传热,考虑了一段钢轨和一个加热元件。结果表明,从加热器向钢轨周围,特别是向地面道碴的热量损失相当大。数值模拟结果很好地揭示了铁路沿线的热量传递情况,并与实验结果进行了验证,两者吻合度很高。这项研究为进一步优化铁路道岔沿线的电阻加热除冰操作奠定了良好基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study of Heat Distribution in Railway Switch Using Resistive Heater in Cold Climate Conditions
The railway is an essential source of logistics and transportation in cold regions, but low temperatures and icing can be challenging for uninterrupted railway operations in these regions. Icing on railway switches is a safety hazard, and presently, one of the industry’s adaptive approaches for ice mitigation is the use of resistive heaters. This method is efficient but consumes a great amount of electricity, leading to high financial costs in terms of the operation and maintenance of railway tracks in ice-prone regions. In this paper, a study is carried out using experiments and computational simulations to analyze the heat distribution in a cross-section of a rail at below-freezing temperatures. Experiments are performed in a cold room using an actual rail switch, thermocouples, and infrared imaging, while numerical analyses are carried out using a MATLAB-based analytical model to simulate the heat transfer, considering a section of stock rail and a heating element. Results show a considerable loss of heat from the heater to the surroundings of the rail, especially towards the ground ballast. Numerical simulation results provide a good insight into heat transfer along railway sections, and results are validated with experiments, where a good agreement is found. This study provides a good base for further optimization of resistive heating operations for ice mitigation along railway switches.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applied Sciences
Applied Sciences Mathematics-Applied Mathematics
CiteScore
6.40
自引率
0.00%
发文量
0
审稿时长
11 weeks
期刊介绍: APPS is an international journal. APPS covers a wide spectrum of pure and applied mathematics in science and technology, promoting especially papers presented at Carpato-Balkan meetings. The Editorial Board of APPS takes a very active role in selecting and refereeing papers, ensuring the best quality of contemporary mathematics and its applications. APPS is abstracted in Zentralblatt für Mathematik. The APPS journal uses Double blind peer review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信