{"title":"双排拼接试验下超高强度混凝土中搭接砂涂层变形 GFRP 钢筋的粘结滑移行为","authors":"Xinyu Hu, Weichen Xue, Jiafei Jiang","doi":"10.1016/j.cemconcomp.2024.105746","DOIUrl":null,"url":null,"abstract":"<div><p>Novel Ultra-High-Performance-Concrete (UHPC) structures reinforced with Fiber-Reinforced Polymer (FRP) rebars are promising candidates for applications in important infrastructures under exposed environments where normal concrete and steel rebars may falter. This paper aims to assess the bond-slip behavior between lapped sand-coated deformed Glass FRP (GFRP) rebars and UHPC using double-row splice tests, with parameters including bar diameter, splice length and lap clearance. Failure modes including the pullout of GFRP rebars and the splitting of UHPC were identified. For cases of pullout failure, the average bond strengths in samples with splice lengths of 5<em>d</em><sub><em>b</em></sub> were reduced by 17.6–22.1 % compared to those of 2.5<em>d</em><sub><em>b</em></sub>. Increasing the lap clearance from 0 to 1<em>d</em><sub><em>b</em></sub> and 2<em>d</em><sub><em>b</em></sub> led to 11.1 % and 30.2 % increases in average bond strengths. Furthermore, average bond-slip models for lapped sand-coated deformed GFRP rebars in UHPC were developed. The predicted curves matched the experimental ones, showing errors within 20 % for both average bond stresses and slips. When the cover is not less than 2<em>d</em><sub><em>b</em></sub>, the splice length is recommended to be at least 15<em>d</em><sub><em>b</em></sub> for sand-coated deformed GFRP rebars with diameters of 10 mm–16 mm in UHPC, approximately 1.25 times the corresponding development length proposed by the existing research.</p></div>","PeriodicalId":9865,"journal":{"name":"Cement & concrete composites","volume":"154 ","pages":"Article 105746"},"PeriodicalIF":10.8000,"publicationDate":"2024-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Bond-slip behavior of lapped sand-coated deformed GFRP rebars in UHPC under double-row splice test\",\"authors\":\"Xinyu Hu, Weichen Xue, Jiafei Jiang\",\"doi\":\"10.1016/j.cemconcomp.2024.105746\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Novel Ultra-High-Performance-Concrete (UHPC) structures reinforced with Fiber-Reinforced Polymer (FRP) rebars are promising candidates for applications in important infrastructures under exposed environments where normal concrete and steel rebars may falter. This paper aims to assess the bond-slip behavior between lapped sand-coated deformed Glass FRP (GFRP) rebars and UHPC using double-row splice tests, with parameters including bar diameter, splice length and lap clearance. Failure modes including the pullout of GFRP rebars and the splitting of UHPC were identified. For cases of pullout failure, the average bond strengths in samples with splice lengths of 5<em>d</em><sub><em>b</em></sub> were reduced by 17.6–22.1 % compared to those of 2.5<em>d</em><sub><em>b</em></sub>. Increasing the lap clearance from 0 to 1<em>d</em><sub><em>b</em></sub> and 2<em>d</em><sub><em>b</em></sub> led to 11.1 % and 30.2 % increases in average bond strengths. Furthermore, average bond-slip models for lapped sand-coated deformed GFRP rebars in UHPC were developed. The predicted curves matched the experimental ones, showing errors within 20 % for both average bond stresses and slips. When the cover is not less than 2<em>d</em><sub><em>b</em></sub>, the splice length is recommended to be at least 15<em>d</em><sub><em>b</em></sub> for sand-coated deformed GFRP rebars with diameters of 10 mm–16 mm in UHPC, approximately 1.25 times the corresponding development length proposed by the existing research.</p></div>\",\"PeriodicalId\":9865,\"journal\":{\"name\":\"Cement & concrete composites\",\"volume\":\"154 \",\"pages\":\"Article 105746\"},\"PeriodicalIF\":10.8000,\"publicationDate\":\"2024-09-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cement & concrete composites\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0958946524003196\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cement & concrete composites","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0958946524003196","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
Bond-slip behavior of lapped sand-coated deformed GFRP rebars in UHPC under double-row splice test
Novel Ultra-High-Performance-Concrete (UHPC) structures reinforced with Fiber-Reinforced Polymer (FRP) rebars are promising candidates for applications in important infrastructures under exposed environments where normal concrete and steel rebars may falter. This paper aims to assess the bond-slip behavior between lapped sand-coated deformed Glass FRP (GFRP) rebars and UHPC using double-row splice tests, with parameters including bar diameter, splice length and lap clearance. Failure modes including the pullout of GFRP rebars and the splitting of UHPC were identified. For cases of pullout failure, the average bond strengths in samples with splice lengths of 5db were reduced by 17.6–22.1 % compared to those of 2.5db. Increasing the lap clearance from 0 to 1db and 2db led to 11.1 % and 30.2 % increases in average bond strengths. Furthermore, average bond-slip models for lapped sand-coated deformed GFRP rebars in UHPC were developed. The predicted curves matched the experimental ones, showing errors within 20 % for both average bond stresses and slips. When the cover is not less than 2db, the splice length is recommended to be at least 15db for sand-coated deformed GFRP rebars with diameters of 10 mm–16 mm in UHPC, approximately 1.25 times the corresponding development length proposed by the existing research.
期刊介绍:
Cement & concrete composites focuses on advancements in cement-concrete composite technology and the production, use, and performance of cement-based construction materials. It covers a wide range of materials, including fiber-reinforced composites, polymer composites, ferrocement, and those incorporating special aggregates or waste materials. Major themes include microstructure, material properties, testing, durability, mechanics, modeling, design, fabrication, and practical applications. The journal welcomes papers on structural behavior, field studies, repair and maintenance, serviceability, and sustainability. It aims to enhance understanding, provide a platform for unconventional materials, promote low-cost energy-saving materials, and bridge the gap between materials science, engineering, and construction. Special issues on emerging topics are also published to encourage collaboration between materials scientists, engineers, designers, and fabricators.