扫描电子显微镜下 EndoActivator、PATS Vario 系统和 XP-endo Finisher 文件去除涂抹层的效果:比较研究。

Rishabh Patel, Gaurav Shinde, Prashant Bondarde, Aruna Vishwakarma, Madhuri Bhandare, Vaibhavi Pharne
{"title":"扫描电子显微镜下 EndoActivator、PATS Vario 系统和 XP-endo Finisher 文件去除涂抹层的效果:比较研究。","authors":"Rishabh Patel, Gaurav Shinde, Prashant Bondarde, Aruna Vishwakarma, Madhuri Bhandare, Vaibhavi Pharne","doi":"10.4103/jisppd.jisppd_233_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Context: </strong>The smear layer may harbor many bacteria; hence, alternative methods are used to disrupt and remove biofilm.</p><p><strong>Aim: </strong>The aim of the study was to compare the effectiveness of EndoActivator, PATS Vario System, and XP-endo Finisher files on smear layer removal using a scanning electron microscope.</p><p><strong>Subjects and methods: </strong>Sixty single-rooted extracted premolars with Vertucci Type 1 configuration were decoronated and divided into four groups. The groups were instrumented with the rotary ProTaper file system. All specimens were flushed with 1 ml of 3% sodium hypochlorite. Group 1 was irrigated with a conventional needle and syringe. In Group 2, the irrigant was activated with an EndoActivator. In Group 3, the irrigant was activated with PATS Vario system, and in Group 4, XP-endo Finisher files were used after biomechanical preparation to remove debris and smear layer. All specimens were finally rinsed with 3 ml of 3% sodium hypochlorite. The teeth underwent longitudinal splitting and grooving in the coronal, middle, and apical thirds, and then, the samples were taken for scanning electron microscopy to evaluate the amount of smear layer removal in each third.</p><p><strong>Results: </strong>The middle and coronal thirds Showed that almost similar efficacy to remove smear layer in both Group II and Group III. At the apical third, Group III showed comparatively better results than Group I, II, and IV, respectively.</p><p><strong>Conclusion: </strong>Equal amount of smear layer was seen with EndoActivator and PATS Vario system when used as sonic irrigation devices.</p>","PeriodicalId":101311,"journal":{"name":"Journal of the Indian Society of Pedodontics and Preventive Dentistry","volume":"42 3","pages":"195-202"},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effectiveness of EndoActivator, PATS Vario system, and XP-endo Finisher files on smear layer removal under scanning electron microscope: A comparative study.\",\"authors\":\"Rishabh Patel, Gaurav Shinde, Prashant Bondarde, Aruna Vishwakarma, Madhuri Bhandare, Vaibhavi Pharne\",\"doi\":\"10.4103/jisppd.jisppd_233_24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Context: </strong>The smear layer may harbor many bacteria; hence, alternative methods are used to disrupt and remove biofilm.</p><p><strong>Aim: </strong>The aim of the study was to compare the effectiveness of EndoActivator, PATS Vario System, and XP-endo Finisher files on smear layer removal using a scanning electron microscope.</p><p><strong>Subjects and methods: </strong>Sixty single-rooted extracted premolars with Vertucci Type 1 configuration were decoronated and divided into four groups. The groups were instrumented with the rotary ProTaper file system. All specimens were flushed with 1 ml of 3% sodium hypochlorite. Group 1 was irrigated with a conventional needle and syringe. In Group 2, the irrigant was activated with an EndoActivator. In Group 3, the irrigant was activated with PATS Vario system, and in Group 4, XP-endo Finisher files were used after biomechanical preparation to remove debris and smear layer. All specimens were finally rinsed with 3 ml of 3% sodium hypochlorite. The teeth underwent longitudinal splitting and grooving in the coronal, middle, and apical thirds, and then, the samples were taken for scanning electron microscopy to evaluate the amount of smear layer removal in each third.</p><p><strong>Results: </strong>The middle and coronal thirds Showed that almost similar efficacy to remove smear layer in both Group II and Group III. At the apical third, Group III showed comparatively better results than Group I, II, and IV, respectively.</p><p><strong>Conclusion: </strong>Equal amount of smear layer was seen with EndoActivator and PATS Vario system when used as sonic irrigation devices.</p>\",\"PeriodicalId\":101311,\"journal\":{\"name\":\"Journal of the Indian Society of Pedodontics and Preventive Dentistry\",\"volume\":\"42 3\",\"pages\":\"195-202\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Indian Society of Pedodontics and Preventive Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jisppd.jisppd_233_24\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Indian Society of Pedodontics and Preventive Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jisppd.jisppd_233_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/9 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:目的:本研究的目的是使用扫描电子显微镜比较 EndoActivator、PATS Vario System 和 XP-endo Finisher 锉刀去除涂抹层的效果:对 60 颗 Vertucci 1 型结构的单根拔除前臼齿进行装饰,并将其分为四组。各组均使用 ProTaper 旋转锉系统。用 1 毫升 3% 次氯酸钠冲洗所有标本。第 1 组使用传统的针头和注射器进行冲洗。第 2 组使用 EndoActivator 激活冲洗剂。第 3 组使用 PATS Vario 系统激活冲洗液,第 4 组在生物力学准备后使用 XP-endo Finisher 锉刀去除碎屑和涂抹层。最后用 3 毫升 3% 次氯酸钠冲洗所有样本。对牙齿的冠状、中间和根尖三部分进行纵向劈裂和开槽,然后取样进行扫描电子显微镜检查,以评估每个三部分的污垢层去除量:结果:第 II 组和第 III 组的中段和冠状段去除涂抹层的效果几乎相似。在根尖三分之一处,第三组的效果分别比第一组、第二组和第四组好:结论:使用 EndoActivator 和 PATS Vario 系统作为声波冲洗设备时,涂抹层的去除量相同。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effectiveness of EndoActivator, PATS Vario system, and XP-endo Finisher files on smear layer removal under scanning electron microscope: A comparative study.

Context: The smear layer may harbor many bacteria; hence, alternative methods are used to disrupt and remove biofilm.

Aim: The aim of the study was to compare the effectiveness of EndoActivator, PATS Vario System, and XP-endo Finisher files on smear layer removal using a scanning electron microscope.

Subjects and methods: Sixty single-rooted extracted premolars with Vertucci Type 1 configuration were decoronated and divided into four groups. The groups were instrumented with the rotary ProTaper file system. All specimens were flushed with 1 ml of 3% sodium hypochlorite. Group 1 was irrigated with a conventional needle and syringe. In Group 2, the irrigant was activated with an EndoActivator. In Group 3, the irrigant was activated with PATS Vario system, and in Group 4, XP-endo Finisher files were used after biomechanical preparation to remove debris and smear layer. All specimens were finally rinsed with 3 ml of 3% sodium hypochlorite. The teeth underwent longitudinal splitting and grooving in the coronal, middle, and apical thirds, and then, the samples were taken for scanning electron microscopy to evaluate the amount of smear layer removal in each third.

Results: The middle and coronal thirds Showed that almost similar efficacy to remove smear layer in both Group II and Group III. At the apical third, Group III showed comparatively better results than Group I, II, and IV, respectively.

Conclusion: Equal amount of smear layer was seen with EndoActivator and PATS Vario system when used as sonic irrigation devices.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信