使用计算机辅助六爪外固定器进行复杂足踝重建--功能效果和并发症分析。

IF 1.9 3区 医学 Q2 ORTHOPEDICS
Felipe Larios, Marcos R Gonzalez, Kim Ruiz-Arellanos, Maria L Inchaustegui, Juan Pretell-Mazzini, Juan Carlos G de la Blanca
{"title":"使用计算机辅助六爪外固定器进行复杂足踝重建--功能效果和并发症分析。","authors":"Felipe Larios, Marcos R Gonzalez, Kim Ruiz-Arellanos, Maria L Inchaustegui, Juan Pretell-Mazzini, Juan Carlos G de la Blanca","doi":"10.1016/j.fas.2024.08.010","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Foot and ankle pathology can often require complex surgical reconstruction. Until recently, circular external fixators such as the Ilizarov frame have proven to be useful, yet they fall short when progressive, precise corrections are required. Computer-assisted hexapod external fixators seek to address many of the shortfalls of traditional circular fixators. However, evidence for their use is scarce. The objective of this work was to evaluate the functional and quality of life outcomes and post-operative complications of patients treated with computer-assisted hexapod external fixation.</p><p><strong>Methods: </strong>A retrospective, observational study was conducted. All cases were treated with either a TrueLok hex (TL-HEX) or a Taylor Spatial Frame (TSF) fixator. Primary outcomes were post-operative improvement in 12-Item Short Form Survey (SF12) and American Orthopaedic Foot and Ankle Score (AOFAS) scores, and complications following Paley's classification.</p><p><strong>Results: </strong>A total of 59 patients with complex foot and ankle conditions using 64 external fixation frames were included. The median sum of both SF12 score domains improved from a preoperative score of 63.6 to 91.3 at last follow-up (p < 0.001). Median AOFAS improved from a preoperative score of 35 to 75.5 at last follow up (p < 0.001). Functional improvement was not affected by the choice of external fixator. Complications occurred in 49 cases (77 %). The most common post-operative complications included pin tract complications in 37 (58 %) cases, joint rigidity in 24 (38 %) and axial deviation in 9 (14 %).</p><p><strong>Conclusions: </strong>Computer-assisted hexapod external fixation is an effective technique to correct complex foot and ankle deformities and leads to a marked improvement in post-operative functional and quality-of-life outcomes with a high minor complication rate.</p>","PeriodicalId":48743,"journal":{"name":"Foot and Ankle Surgery","volume":" ","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Use of computer-assisted hexapod external fixators for complex foot and ankle reconstructions - An analysis of functional outcomes and complications.\",\"authors\":\"Felipe Larios, Marcos R Gonzalez, Kim Ruiz-Arellanos, Maria L Inchaustegui, Juan Pretell-Mazzini, Juan Carlos G de la Blanca\",\"doi\":\"10.1016/j.fas.2024.08.010\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Foot and ankle pathology can often require complex surgical reconstruction. Until recently, circular external fixators such as the Ilizarov frame have proven to be useful, yet they fall short when progressive, precise corrections are required. Computer-assisted hexapod external fixators seek to address many of the shortfalls of traditional circular fixators. However, evidence for their use is scarce. The objective of this work was to evaluate the functional and quality of life outcomes and post-operative complications of patients treated with computer-assisted hexapod external fixation.</p><p><strong>Methods: </strong>A retrospective, observational study was conducted. All cases were treated with either a TrueLok hex (TL-HEX) or a Taylor Spatial Frame (TSF) fixator. Primary outcomes were post-operative improvement in 12-Item Short Form Survey (SF12) and American Orthopaedic Foot and Ankle Score (AOFAS) scores, and complications following Paley's classification.</p><p><strong>Results: </strong>A total of 59 patients with complex foot and ankle conditions using 64 external fixation frames were included. The median sum of both SF12 score domains improved from a preoperative score of 63.6 to 91.3 at last follow-up (p < 0.001). Median AOFAS improved from a preoperative score of 35 to 75.5 at last follow up (p < 0.001). Functional improvement was not affected by the choice of external fixator. Complications occurred in 49 cases (77 %). The most common post-operative complications included pin tract complications in 37 (58 %) cases, joint rigidity in 24 (38 %) and axial deviation in 9 (14 %).</p><p><strong>Conclusions: </strong>Computer-assisted hexapod external fixation is an effective technique to correct complex foot and ankle deformities and leads to a marked improvement in post-operative functional and quality-of-life outcomes with a high minor complication rate.</p>\",\"PeriodicalId\":48743,\"journal\":{\"name\":\"Foot and Ankle Surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Foot and Ankle Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.fas.2024.08.010\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Foot and Ankle Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.fas.2024.08.010","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

简介足踝病变通常需要复杂的手术重建。直到最近,Ilizarov 架等圆形外固定器仍被证明是有用的,但在需要渐进、精确矫正时,它们就显得不足了。计算机辅助六脚外固定器试图解决传统圆形外固定器的许多不足之处。然而,使用它们的证据却很少。这项研究的目的是评估使用计算机辅助六脚外固定器治疗患者的功能和生活质量以及术后并发症:方法:进行了一项回顾性观察研究。所有病例均采用 TrueLok hex (TL-HEX) 或 Taylor Spatial Frame (TSF) 固定器进行治疗。主要结果是术后 12 项简表调查(SF12)和美国骨科足踝评分(AOFAS)的改善情况,以及根据帕利分类法得出的并发症情况:结果:共纳入了59名使用64个外固定架的复杂足踝疾病患者。两个 SF12 评分域的中位数总和从术前的 63.6 分提高到最后一次随访时的 91.3 分(P 结论:患者的 SF12 评分域中位数总和从术前的 63.6 分提高到最后一次随访时的 91.3 分:计算机辅助六脚架外固定术是矫正复杂足踝畸形的有效技术,可显著改善术后功能和生活质量,但并发症发生率较高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Use of computer-assisted hexapod external fixators for complex foot and ankle reconstructions - An analysis of functional outcomes and complications.

Introduction: Foot and ankle pathology can often require complex surgical reconstruction. Until recently, circular external fixators such as the Ilizarov frame have proven to be useful, yet they fall short when progressive, precise corrections are required. Computer-assisted hexapod external fixators seek to address many of the shortfalls of traditional circular fixators. However, evidence for their use is scarce. The objective of this work was to evaluate the functional and quality of life outcomes and post-operative complications of patients treated with computer-assisted hexapod external fixation.

Methods: A retrospective, observational study was conducted. All cases were treated with either a TrueLok hex (TL-HEX) or a Taylor Spatial Frame (TSF) fixator. Primary outcomes were post-operative improvement in 12-Item Short Form Survey (SF12) and American Orthopaedic Foot and Ankle Score (AOFAS) scores, and complications following Paley's classification.

Results: A total of 59 patients with complex foot and ankle conditions using 64 external fixation frames were included. The median sum of both SF12 score domains improved from a preoperative score of 63.6 to 91.3 at last follow-up (p < 0.001). Median AOFAS improved from a preoperative score of 35 to 75.5 at last follow up (p < 0.001). Functional improvement was not affected by the choice of external fixator. Complications occurred in 49 cases (77 %). The most common post-operative complications included pin tract complications in 37 (58 %) cases, joint rigidity in 24 (38 %) and axial deviation in 9 (14 %).

Conclusions: Computer-assisted hexapod external fixation is an effective technique to correct complex foot and ankle deformities and leads to a marked improvement in post-operative functional and quality-of-life outcomes with a high minor complication rate.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Foot and Ankle Surgery
Foot and Ankle Surgery ORTHOPEDICS-
CiteScore
4.60
自引率
16.00%
发文量
202
期刊介绍: Foot and Ankle Surgery is essential reading for everyone interested in the foot and ankle and its disorders. The approach is broad and includes all aspects of the subject from basic science to clinical management. Problems of both children and adults are included, as is trauma and chronic disease. Foot and Ankle Surgery is the official journal of European Foot and Ankle Society. The aims of this journal are to promote the art and science of ankle and foot surgery, to publish peer-reviewed research articles, to provide regular reviews by acknowledged experts on common problems, and to provide a forum for discussion with letters to the Editors. Reviews of books are also published. Papers are invited for possible publication in Foot and Ankle Surgery on the understanding that the material has not been published elsewhere or accepted for publication in another journal and does not infringe prior copyright.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信