使用不同曝光参数对 CBCT 生成的数字模型进行测量的准确性(体外研究)。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
Noura Ibrahim, Hassan Mohamed Abouelkheir, Noha Mohamed Elkersh
{"title":"使用不同曝光参数对 CBCT 生成的数字模型进行测量的准确性(体外研究)。","authors":"Noura Ibrahim, Hassan Mohamed Abouelkheir, Noha Mohamed Elkersh","doi":"10.1111/ocr.12854","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Dental imaging comprises a wide range of techniques and modalities, each with different diagnostic features influenced by numerous parameters, all of which contribute to the precision and effectiveness of dental evaluations and treatments. This study examined the dimensional reproducibility of arch measurements from CBCT scans with different voxel sizes and exposure parameters compared to a reference model from Extra-oral scanners (EOS) and how these parameters affected digital matching and diagnostic image quality.</p><p><strong>Methods: </strong>A diagnostic observational study of arch dimensions, including inter-canine, inter-premolar, intermolar, arch width and arch length, was conducted on digital models (DMs) created from 65 CBCT scans of a full dentate epoxy maxillary model. The measurements obtained from EOS scans served as the control for the study. Normality was tested with the Shapiro-Wilk test, comparisons used the Kruskal-Wallis test with Bonferroni-adjusted pairwise comparisons for significant results, and data were analysed using IBM SPSS (Version 26.0), with significance set at p < .05.</p><p><strong>Results: </strong>Significant deviations were revealed among study groups, with group I (smallest voxel size) consistently displaying the lowest values, mean (SD) deviation was reported as 0.01 (0.006) and group IV (lowest kV value) exhibiting the highest deviations, mean (SD) deviation of 0.16 (0.17).</p><p><strong>Conclusion: </strong>Combining a small voxel size (0.12 mm) with high milliampere (8 mA) and kilovoltage (90 kV) settings in CBCT ensured detailed anatomical visualization and accurate linear measurements, crucial for precise dental assessments, and emphasizing the necessity for strict control over CBCT parameters in dental applications.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accuracy of measurements on CBCT-generated digital models using different exposure parameters (in vitro study).\",\"authors\":\"Noura Ibrahim, Hassan Mohamed Abouelkheir, Noha Mohamed Elkersh\",\"doi\":\"10.1111/ocr.12854\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Dental imaging comprises a wide range of techniques and modalities, each with different diagnostic features influenced by numerous parameters, all of which contribute to the precision and effectiveness of dental evaluations and treatments. This study examined the dimensional reproducibility of arch measurements from CBCT scans with different voxel sizes and exposure parameters compared to a reference model from Extra-oral scanners (EOS) and how these parameters affected digital matching and diagnostic image quality.</p><p><strong>Methods: </strong>A diagnostic observational study of arch dimensions, including inter-canine, inter-premolar, intermolar, arch width and arch length, was conducted on digital models (DMs) created from 65 CBCT scans of a full dentate epoxy maxillary model. The measurements obtained from EOS scans served as the control for the study. Normality was tested with the Shapiro-Wilk test, comparisons used the Kruskal-Wallis test with Bonferroni-adjusted pairwise comparisons for significant results, and data were analysed using IBM SPSS (Version 26.0), with significance set at p < .05.</p><p><strong>Results: </strong>Significant deviations were revealed among study groups, with group I (smallest voxel size) consistently displaying the lowest values, mean (SD) deviation was reported as 0.01 (0.006) and group IV (lowest kV value) exhibiting the highest deviations, mean (SD) deviation of 0.16 (0.17).</p><p><strong>Conclusion: </strong>Combining a small voxel size (0.12 mm) with high milliampere (8 mA) and kilovoltage (90 kV) settings in CBCT ensured detailed anatomical visualization and accurate linear measurements, crucial for precise dental assessments, and emphasizing the necessity for strict control over CBCT parameters in dental applications.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-09-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/ocr.12854\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/ocr.12854","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

导言:牙科成像由多种技术和模式组成,每种技术和模式都有不同的诊断特征,受众多参数的影响,所有这些都有助于提高牙科评估和治疗的精确性和有效性。本研究将不同体素大小和曝光参数的 CBCT 扫描结果与口外扫描仪(EOS)的参考模型进行比较,考察其牙弓测量值的尺寸再现性,以及这些参数对数字匹配和诊断图像质量的影响:通过对65个环氧树脂上颌全齿模型的CBCT扫描创建的数字模型(DMs),对牙弓尺寸(包括犬间、腭间、臼间、牙弓宽度和牙弓长度)进行了诊断观察研究。通过 EOS 扫描获得的测量结果作为研究的对照。正态性采用 Shapiro-Wilk 检验,比较采用 Kruskal-Wallis 检验,显著结果采用 Bonferroni-adjusted 配对比较,数据采用 IBM SPSS(26.0 版)分析,显著性设置为 p:各研究组之间存在显著偏差,第一组(体素尺寸最小)始终显示最低值,平均(标清)偏差为 0.01(0.006),第四组(kV 值最低)显示最高偏差,平均(标清)偏差为 0.16(0.17):将 CBCT 中的小体素尺寸(0.12 毫米)与高毫安培(8 毫安)和高电压(90 千伏)设置相结合,可确保详细的解剖可视化和精确的线性测量,这对精确的牙科评估至关重要,同时强调了在牙科应用中严格控制 CBCT 参数的必要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accuracy of measurements on CBCT-generated digital models using different exposure parameters (in vitro study).

Introduction: Dental imaging comprises a wide range of techniques and modalities, each with different diagnostic features influenced by numerous parameters, all of which contribute to the precision and effectiveness of dental evaluations and treatments. This study examined the dimensional reproducibility of arch measurements from CBCT scans with different voxel sizes and exposure parameters compared to a reference model from Extra-oral scanners (EOS) and how these parameters affected digital matching and diagnostic image quality.

Methods: A diagnostic observational study of arch dimensions, including inter-canine, inter-premolar, intermolar, arch width and arch length, was conducted on digital models (DMs) created from 65 CBCT scans of a full dentate epoxy maxillary model. The measurements obtained from EOS scans served as the control for the study. Normality was tested with the Shapiro-Wilk test, comparisons used the Kruskal-Wallis test with Bonferroni-adjusted pairwise comparisons for significant results, and data were analysed using IBM SPSS (Version 26.0), with significance set at p < .05.

Results: Significant deviations were revealed among study groups, with group I (smallest voxel size) consistently displaying the lowest values, mean (SD) deviation was reported as 0.01 (0.006) and group IV (lowest kV value) exhibiting the highest deviations, mean (SD) deviation of 0.16 (0.17).

Conclusion: Combining a small voxel size (0.12 mm) with high milliampere (8 mA) and kilovoltage (90 kV) settings in CBCT ensured detailed anatomical visualization and accurate linear measurements, crucial for precise dental assessments, and emphasizing the necessity for strict control over CBCT parameters in dental applications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信