优化针头配置,提高前列腺种子植入手术(ONCOSEED)的效率和部署

Q1 Nursing
Siddhant Sen , Ethan Stolen , Jaehee Chun , Jin Sung Kim , James J. Sohn
{"title":"优化针头配置,提高前列腺种子植入手术(ONCOSEED)的效率和部署","authors":"Siddhant Sen ,&nbsp;Ethan Stolen ,&nbsp;Jaehee Chun ,&nbsp;Jin Sung Kim ,&nbsp;James J. Sohn","doi":"10.1016/j.tipsro.2024.100273","DOIUrl":null,"url":null,"abstract":"<div><p>Due to anatomical changes between pre-planning and implantation, there exists a need for tools that can streamline the adjustment of needle and seed configurations in low dose rate brachytherapy for prostate cancer. Specifically, upon taking a second ultrasound on the day of treatment, the distribution of seeds and needles will differ drastically from the original plan. Clinics that employ this method must then spend time and resources to generate a workflow to manipulate the original configuration to the new configuration. ONCOSEED extracts data from VariSeed treatment plans, calculating a labor score (LScore) to optimize adjustments to needle configurations. A case study of three simulated VariSeed treatment plans was used to compare the ONCOSEED software to the manual method of generating a workflow. In the same method that was used at the authors’ clinic, several assistants annotated by hand the original plan to convert it to the new plan. The time taken to do so was recorded and compared to the runtime of the software when generating a workflow for the same plan. Results showed that ONCOSEED was on average 28 times faster than generating a workflow by hand. ONCOSEED enhances the efficiency of seed replacement in LDR brachytherapy, promoting the adoption of adaptive brachytherapy practices.</p></div>","PeriodicalId":36328,"journal":{"name":"Technical Innovations and Patient Support in Radiation Oncology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2405632424000404/pdfft?md5=07aef45c04b54114bac9cc376fd4fd18&pid=1-s2.0-S2405632424000404-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Optimized needle configuration for operational seed (ONCOSEED) efficiency and deployment for prostate seed implants\",\"authors\":\"Siddhant Sen ,&nbsp;Ethan Stolen ,&nbsp;Jaehee Chun ,&nbsp;Jin Sung Kim ,&nbsp;James J. Sohn\",\"doi\":\"10.1016/j.tipsro.2024.100273\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Due to anatomical changes between pre-planning and implantation, there exists a need for tools that can streamline the adjustment of needle and seed configurations in low dose rate brachytherapy for prostate cancer. Specifically, upon taking a second ultrasound on the day of treatment, the distribution of seeds and needles will differ drastically from the original plan. Clinics that employ this method must then spend time and resources to generate a workflow to manipulate the original configuration to the new configuration. ONCOSEED extracts data from VariSeed treatment plans, calculating a labor score (LScore) to optimize adjustments to needle configurations. A case study of three simulated VariSeed treatment plans was used to compare the ONCOSEED software to the manual method of generating a workflow. In the same method that was used at the authors’ clinic, several assistants annotated by hand the original plan to convert it to the new plan. The time taken to do so was recorded and compared to the runtime of the software when generating a workflow for the same plan. Results showed that ONCOSEED was on average 28 times faster than generating a workflow by hand. ONCOSEED enhances the efficiency of seed replacement in LDR brachytherapy, promoting the adoption of adaptive brachytherapy practices.</p></div>\",\"PeriodicalId\":36328,\"journal\":{\"name\":\"Technical Innovations and Patient Support in Radiation Oncology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2405632424000404/pdfft?md5=07aef45c04b54114bac9cc376fd4fd18&pid=1-s2.0-S2405632424000404-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Technical Innovations and Patient Support in Radiation Oncology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2405632424000404\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Nursing\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technical Innovations and Patient Support in Radiation Oncology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2405632424000404","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Nursing","Score":null,"Total":0}
引用次数: 0

摘要

由于在预规划和植入之间解剖结构会发生变化,因此需要能简化前列腺癌低剂量近距离放射治疗中针头和种子配置调整的工具。具体来说,在治疗当天进行第二次超声波检查时,种子和针头的分布会与最初的计划大相径庭。采用这种方法的诊所必须花费时间和资源来生成一个工作流程,以便将原始配置调整为新配置。ONCOSEED 可从 VariSeed 治疗计划中提取数据,计算劳动分数 (LScore),优化针头配置的调整。通过对三个模拟 VariSeed 治疗计划的案例研究,对 ONCOSEED 软件和手动生成工作流程的方法进行了比较。几位助手采用与作者诊所相同的方法,手工注释原始计划,将其转换为新计划。所花费的时间被记录下来,并与软件为同一计划生成工作流程的运行时间进行比较。结果显示,ONCOSEED 比手工生成工作流程平均快 28 倍。ONCOSEED 提高了 LDR 近距离放射治疗中种子置换的效率,促进了适应性近距离放射治疗实践的采用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimized needle configuration for operational seed (ONCOSEED) efficiency and deployment for prostate seed implants

Due to anatomical changes between pre-planning and implantation, there exists a need for tools that can streamline the adjustment of needle and seed configurations in low dose rate brachytherapy for prostate cancer. Specifically, upon taking a second ultrasound on the day of treatment, the distribution of seeds and needles will differ drastically from the original plan. Clinics that employ this method must then spend time and resources to generate a workflow to manipulate the original configuration to the new configuration. ONCOSEED extracts data from VariSeed treatment plans, calculating a labor score (LScore) to optimize adjustments to needle configurations. A case study of three simulated VariSeed treatment plans was used to compare the ONCOSEED software to the manual method of generating a workflow. In the same method that was used at the authors’ clinic, several assistants annotated by hand the original plan to convert it to the new plan. The time taken to do so was recorded and compared to the runtime of the software when generating a workflow for the same plan. Results showed that ONCOSEED was on average 28 times faster than generating a workflow by hand. ONCOSEED enhances the efficiency of seed replacement in LDR brachytherapy, promoting the adoption of adaptive brachytherapy practices.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
0.00%
发文量
48
审稿时长
67 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信