根据美国医学物理学家协会工作组-263 报告,对基础大型语言模型重新标注结构名称的能力进行基准测试。

IF 3.4 3区 医学 Q2 ONCOLOGY
Jason Holmes, Lian Zhang, Yuzhen Ding, Hongying Feng, Zhengliang Liu, Tianming Liu, William W Wong, Sujay A Vora, Jonathan B Ashman, Wei Liu
{"title":"根据美国医学物理学家协会工作组-263 报告,对基础大型语言模型重新标注结构名称的能力进行基准测试。","authors":"Jason Holmes, Lian Zhang, Yuzhen Ding, Hongying Feng, Zhengliang Liu, Tianming Liu, William W Wong, Sujay A Vora, Jonathan B Ashman, Wei Liu","doi":"10.1016/j.prro.2024.04.017","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To introduce the concept of using large language models (LLMs) to relabel structure names in accordance with the American Association of Physicists in Medicine Task Group-263 standard and to establish a benchmark for future studies to reference.</p><p><strong>Methods and materials: </strong>Generative Pretrained Transformer (GPT)-4 was implemented within a Digital Imaging and Communications in Medicine server. Upon receiving a structure-set Digital Imaging and Communications in Medicine file, the server prompts GPT-4 to relabel the structure names according to the American Association of Physicists in Medicine Task Group-263 report. The results were evaluated for 3 disease sites: prostate, head and neck, and thorax. For each disease site, 150 patients were randomly selected for manually tuning the instructions prompt (in batches of 50), and 50 patients were randomly selected for evaluation. Structure names considered were those that were most likely to be relevant for studies using structure contours for many patients.</p><p><strong>Results: </strong>The per-patient accuracy was 97.2%, 98.3%, and 97.1% for prostate, head and neck, and thorax disease sites, respectively. On a per-structure basis, the clinical target volume was relabeled correctly in 100%, 95.3%, and 92.9% of cases, respectively.</p><p><strong>Conclusions: </strong>Given the accuracy of GPT-4 in relabeling structure names as presented in this work, LLMs are poised to become an important method for standardizing structure names in radiation oncology, especially considering the rapid advancements in LLM capabilities that are likely to continue.</p>","PeriodicalId":54245,"journal":{"name":"Practical Radiation Oncology","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Benchmarking a Foundation Large Language Model on its Ability to Relabel Structure Names in Accordance With the American Association of Physicists in Medicine Task Group-263 Report.\",\"authors\":\"Jason Holmes, Lian Zhang, Yuzhen Ding, Hongying Feng, Zhengliang Liu, Tianming Liu, William W Wong, Sujay A Vora, Jonathan B Ashman, Wei Liu\",\"doi\":\"10.1016/j.prro.2024.04.017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To introduce the concept of using large language models (LLMs) to relabel structure names in accordance with the American Association of Physicists in Medicine Task Group-263 standard and to establish a benchmark for future studies to reference.</p><p><strong>Methods and materials: </strong>Generative Pretrained Transformer (GPT)-4 was implemented within a Digital Imaging and Communications in Medicine server. Upon receiving a structure-set Digital Imaging and Communications in Medicine file, the server prompts GPT-4 to relabel the structure names according to the American Association of Physicists in Medicine Task Group-263 report. The results were evaluated for 3 disease sites: prostate, head and neck, and thorax. For each disease site, 150 patients were randomly selected for manually tuning the instructions prompt (in batches of 50), and 50 patients were randomly selected for evaluation. Structure names considered were those that were most likely to be relevant for studies using structure contours for many patients.</p><p><strong>Results: </strong>The per-patient accuracy was 97.2%, 98.3%, and 97.1% for prostate, head and neck, and thorax disease sites, respectively. On a per-structure basis, the clinical target volume was relabeled correctly in 100%, 95.3%, and 92.9% of cases, respectively.</p><p><strong>Conclusions: </strong>Given the accuracy of GPT-4 in relabeling structure names as presented in this work, LLMs are poised to become an important method for standardizing structure names in radiation oncology, especially considering the rapid advancements in LLM capabilities that are likely to continue.</p>\",\"PeriodicalId\":54245,\"journal\":{\"name\":\"Practical Radiation Oncology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-07-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Practical Radiation Oncology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.prro.2024.04.017\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ONCOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Practical Radiation Oncology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prro.2024.04.017","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:介绍使用大型语言模型(LLM)按照美国物理学家协会医学工作组-263 标准重新标注结构名称的概念,并为今后的研究建立一个参考基准:生成式预训练变换器(GPT)-4 在医学数字成像与通信服务器中实施。服务器接收到结构集数字成像与医学通信文件后,会提示 GPT-4 根据美国物理学家协会医学工作组-263 报告重新标注结构名称。评估结果针对 3 个疾病部位:前列腺、头颈部和胸部。针对每个疾病部位,随机抽取 150 名患者手动调整指示提示(每批 50 人),并随机抽取 50 名患者进行评估。所考虑的结构名称是那些最有可能与对许多患者使用结构轮廓进行研究相关的名称:前列腺、头颈部和胸部疾病部位的每位患者准确率分别为 97.2%、98.3% 和 97.1%。就每个结构而言,分别有 100%、95.3% 和 92.9% 的病例正确地重新标记了临床靶体积:鉴于 GPT-4 在重新标注结构名称方面的准确性,LLM 将成为放射肿瘤学中标准化结构名称的重要方法,特别是考虑到 LLM 功能可能会继续快速发展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Benchmarking a Foundation Large Language Model on its Ability to Relabel Structure Names in Accordance With the American Association of Physicists in Medicine Task Group-263 Report.

Purpose: To introduce the concept of using large language models (LLMs) to relabel structure names in accordance with the American Association of Physicists in Medicine Task Group-263 standard and to establish a benchmark for future studies to reference.

Methods and materials: Generative Pretrained Transformer (GPT)-4 was implemented within a Digital Imaging and Communications in Medicine server. Upon receiving a structure-set Digital Imaging and Communications in Medicine file, the server prompts GPT-4 to relabel the structure names according to the American Association of Physicists in Medicine Task Group-263 report. The results were evaluated for 3 disease sites: prostate, head and neck, and thorax. For each disease site, 150 patients were randomly selected for manually tuning the instructions prompt (in batches of 50), and 50 patients were randomly selected for evaluation. Structure names considered were those that were most likely to be relevant for studies using structure contours for many patients.

Results: The per-patient accuracy was 97.2%, 98.3%, and 97.1% for prostate, head and neck, and thorax disease sites, respectively. On a per-structure basis, the clinical target volume was relabeled correctly in 100%, 95.3%, and 92.9% of cases, respectively.

Conclusions: Given the accuracy of GPT-4 in relabeling structure names as presented in this work, LLMs are poised to become an important method for standardizing structure names in radiation oncology, especially considering the rapid advancements in LLM capabilities that are likely to continue.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Practical Radiation Oncology
Practical Radiation Oncology Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
5.20
自引率
6.10%
发文量
177
审稿时长
34 days
期刊介绍: The overarching mission of Practical Radiation Oncology is to improve the quality of radiation oncology practice. PRO''s purpose is to document the state of current practice, providing background for those in training and continuing education for practitioners, through discussion and illustration of new techniques, evaluation of current practices, and publication of case reports. PRO strives to provide its readers content that emphasizes knowledge "with a purpose." The content of PRO includes: Original articles focusing on patient safety, quality measurement, or quality improvement initiatives Original articles focusing on imaging, contouring, target delineation, simulation, treatment planning, immobilization, organ motion, and other practical issues ASTRO guidelines, position papers, and consensus statements Essays that highlight enriching personal experiences in caring for cancer patients and their families.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信