大型临床试验中多重定量临床化学蛋白质组学的质量保证。

IF 1.8 Q3 MEDICAL LABORATORY TECHNOLOGY
Esther Reijnders, Fred P H T M Romijn, Figen Arslan, Julien J J Georges, Mervin M Pieterse, Edwin R Schipper, Sonja Didden-Buitendijk, Machteld C Martherus-Bultman, Nico P M Smit, Nina M Diederiks, Maxim M Treep, J Wouter Jukema, Christa M Cobbaert, L Renee Ruhaak
{"title":"大型临床试验中多重定量临床化学蛋白质组学的质量保证。","authors":"Esther Reijnders, Fred P H T M Romijn, Figen Arslan, Julien J J Georges, Mervin M Pieterse, Edwin R Schipper, Sonja Didden-Buitendijk, Machteld C Martherus-Bultman, Nico P M Smit, Nina M Diederiks, Maxim M Treep, J Wouter Jukema, Christa M Cobbaert, L Renee Ruhaak","doi":"10.1093/jalm/jfae092","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To evaluate the clinical performance and effectiveness of a multiplex apolipoprotein panel in the context of cardiovascular precision diagnostics, clinical samples of patients with recent acute coronary syndrome in the ODYSSEY OUTCOMES trial were measured by quantitative clinical chemistry proteomics (qCCP). The ISO15189-accredited laboratory setting, including the total testing process (TTP), served as a foundation for this study. Consequently, tailored quality assurance measures needed to be designed and implemented to suit the demands of a multiplex LC-MS/MS test.</p><p><strong>Methods: </strong>Nine serum apolipoproteins were measured in 23 376 samples with a laboratory-developed multiplex apolipoprotein test on 4 Agilent 6495 LC-MS/MS systems. A fit-for-purpose process was designed with tailored additions enhancing the accredited laboratory infrastructure and the TTP. Quality assurance was organized in 3 steps: system suitability testing (SST), internal quality control (IQC) evaluation with adjusted Westgard rules to fit a multiplex test, and interpeptide agreement analysis. Data was semi-automatically evaluated with a custom R script.</p><p><strong>Results: </strong>LC-MS/MS analyses were performed with the following between-run CVs: for apolipoprotein (Apo) (a) 6.2%, Apo A-I 2.3%, Apo A-II 2.1%, Apo A-IV 2.9%, Apo B 1.9%, Apo C-I 3.3%, Apo C-II 3.3%, Apo C-III 2.7%, and for Apo E 3.3% and an average interpeptide agreement Pearson r of 0.981.</p><p><strong>Conclusions: </strong>This is the first study of its kind in which qCCP was performed at this scale. This research successfully demonstrates the feasibility of high-throughput LC-MS/MS applications in large clinical trials. ClinicalTrials.gov Registration Number: NCT01663402.</p>","PeriodicalId":46361,"journal":{"name":"Journal of Applied Laboratory Medicine","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quality Assurance for Multiplex Quantitative Clinical Chemistry Proteomics in Large Clinical Trials.\",\"authors\":\"Esther Reijnders, Fred P H T M Romijn, Figen Arslan, Julien J J Georges, Mervin M Pieterse, Edwin R Schipper, Sonja Didden-Buitendijk, Machteld C Martherus-Bultman, Nico P M Smit, Nina M Diederiks, Maxim M Treep, J Wouter Jukema, Christa M Cobbaert, L Renee Ruhaak\",\"doi\":\"10.1093/jalm/jfae092\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>To evaluate the clinical performance and effectiveness of a multiplex apolipoprotein panel in the context of cardiovascular precision diagnostics, clinical samples of patients with recent acute coronary syndrome in the ODYSSEY OUTCOMES trial were measured by quantitative clinical chemistry proteomics (qCCP). The ISO15189-accredited laboratory setting, including the total testing process (TTP), served as a foundation for this study. Consequently, tailored quality assurance measures needed to be designed and implemented to suit the demands of a multiplex LC-MS/MS test.</p><p><strong>Methods: </strong>Nine serum apolipoproteins were measured in 23 376 samples with a laboratory-developed multiplex apolipoprotein test on 4 Agilent 6495 LC-MS/MS systems. A fit-for-purpose process was designed with tailored additions enhancing the accredited laboratory infrastructure and the TTP. Quality assurance was organized in 3 steps: system suitability testing (SST), internal quality control (IQC) evaluation with adjusted Westgard rules to fit a multiplex test, and interpeptide agreement analysis. Data was semi-automatically evaluated with a custom R script.</p><p><strong>Results: </strong>LC-MS/MS analyses were performed with the following between-run CVs: for apolipoprotein (Apo) (a) 6.2%, Apo A-I 2.3%, Apo A-II 2.1%, Apo A-IV 2.9%, Apo B 1.9%, Apo C-I 3.3%, Apo C-II 3.3%, Apo C-III 2.7%, and for Apo E 3.3% and an average interpeptide agreement Pearson r of 0.981.</p><p><strong>Conclusions: </strong>This is the first study of its kind in which qCCP was performed at this scale. This research successfully demonstrates the feasibility of high-throughput LC-MS/MS applications in large clinical trials. ClinicalTrials.gov Registration Number: NCT01663402.</p>\",\"PeriodicalId\":46361,\"journal\":{\"name\":\"Journal of Applied Laboratory Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Laboratory Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/jalm/jfae092\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jalm/jfae092","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:为了评估心血管精准诊断中多重载脂蛋白面板的临床性能和有效性,我们采用定量临床化学蛋白质组学(qCCP)方法测量了ODYSSEY OUTCOMES试验中近期急性冠状动脉综合征患者的临床样本。通过 ISO15189 认证的实验室环境(包括整个检测流程 (TTP))是本研究的基础。因此,需要设计和实施量身定制的质量保证措施,以适应多重 LC-MS/MS 检测的要求:方法:在 4 套 Agilent 6495 LC-MS/MS 系统上使用实验室开发的多重脂蛋白检测方法对 23 376 份样本中的 9 种血清脂蛋白进行了检测。设计了一个适合目的的流程,并根据需要增加了增强认可实验室基础设施和 TTP 的内容。质量保证分为 3 个步骤:系统适用性测试 (SST)、使用调整后的 Westgard 规则进行内部质量控制 (IQC) 评估以适应多重检测,以及肽间一致性分析。数据通过定制的 R 脚本进行半自动评估:结果:LC-MS/MS分析的运行间变异系数如下:载脂蛋白(载脂蛋白A)(a)6.2%、载脂蛋白A-I 2.3%、载脂蛋白A-II 2.1%、载脂蛋白A-IV 2.9%、载脂蛋白B 1.9%、载脂蛋白C-I 3.3%、载脂蛋白C-II 3.3%、载脂蛋白C-III 2.7%、载脂蛋白E 3.3%,平均肽间一致性Pearson r为0.981:这是首次在如此大规模上进行 qCCP 的同类研究。这项研究成功证明了高通量 LC-MS/MS 应用于大型临床试验的可行性。ClinicalTrials.gov 注册号:NCT01663402:NCT01663402。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Quality Assurance for Multiplex Quantitative Clinical Chemistry Proteomics in Large Clinical Trials.

Background: To evaluate the clinical performance and effectiveness of a multiplex apolipoprotein panel in the context of cardiovascular precision diagnostics, clinical samples of patients with recent acute coronary syndrome in the ODYSSEY OUTCOMES trial were measured by quantitative clinical chemistry proteomics (qCCP). The ISO15189-accredited laboratory setting, including the total testing process (TTP), served as a foundation for this study. Consequently, tailored quality assurance measures needed to be designed and implemented to suit the demands of a multiplex LC-MS/MS test.

Methods: Nine serum apolipoproteins were measured in 23 376 samples with a laboratory-developed multiplex apolipoprotein test on 4 Agilent 6495 LC-MS/MS systems. A fit-for-purpose process was designed with tailored additions enhancing the accredited laboratory infrastructure and the TTP. Quality assurance was organized in 3 steps: system suitability testing (SST), internal quality control (IQC) evaluation with adjusted Westgard rules to fit a multiplex test, and interpeptide agreement analysis. Data was semi-automatically evaluated with a custom R script.

Results: LC-MS/MS analyses were performed with the following between-run CVs: for apolipoprotein (Apo) (a) 6.2%, Apo A-I 2.3%, Apo A-II 2.1%, Apo A-IV 2.9%, Apo B 1.9%, Apo C-I 3.3%, Apo C-II 3.3%, Apo C-III 2.7%, and for Apo E 3.3% and an average interpeptide agreement Pearson r of 0.981.

Conclusions: This is the first study of its kind in which qCCP was performed at this scale. This research successfully demonstrates the feasibility of high-throughput LC-MS/MS applications in large clinical trials. ClinicalTrials.gov Registration Number: NCT01663402.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Applied Laboratory Medicine
Journal of Applied Laboratory Medicine MEDICAL LABORATORY TECHNOLOGY-
CiteScore
3.70
自引率
5.00%
发文量
137
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信