金属氧化物对加成制造镍钛生物相容性的影响

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Maria P Kwesiga, Roger J Guillory, Ali Gökhan Demir
{"title":"金属氧化物对加成制造镍钛生物相容性的影响","authors":"Maria P Kwesiga, Roger J Guillory, Ali Gökhan Demir","doi":"10.1116/6.0003665","DOIUrl":null,"url":null,"abstract":"<p><p>In order to properly satisfy biomedical constraints for cardiovascular applications, additively manufactured NiTi scaffolds required further process and metallurgical engineering. Additively manufactured NiTi materials for cardiovascular use will have to undergo surface finishing in order to minimize negative surface interactions within the artery. In this study, we sought to understand biocompatibility from chemically etched additively manufactured NiTi scaffolds by laser powder bed fusion (LPBF). Although two distinct oxide films were created in the surface etching process (labeled CP-A and CP-B), no qualitative changes in microroughness were seen between the two conditions. CP-A possessed significantly less Ni at the surface (0.19 at. %) than the CP-B group (3.30 at. %), via x-ray photoelectron spectroscopy, alongside a concomitant shift in the O1 s peak presentation alluding to a greater formation of a Ni based oxide in the CP-B group. Our live dead staining revealed significant toxicity and reduced cellular attachment for the CP-B group, in addition to inducing more cell lysis (20.9 ± 5.1%), which was significantly increased when compared to CP-A (P < 0.01). Future practices of manufacturing NiTi scaffolds using LPBF should focus on producing surface films that are not only smooth, but free of cytotoxic Ni based oxides.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of metal oxides on biocompatibility of additively manufactured NiTi.\",\"authors\":\"Maria P Kwesiga, Roger J Guillory, Ali Gökhan Demir\",\"doi\":\"10.1116/6.0003665\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In order to properly satisfy biomedical constraints for cardiovascular applications, additively manufactured NiTi scaffolds required further process and metallurgical engineering. Additively manufactured NiTi materials for cardiovascular use will have to undergo surface finishing in order to minimize negative surface interactions within the artery. In this study, we sought to understand biocompatibility from chemically etched additively manufactured NiTi scaffolds by laser powder bed fusion (LPBF). Although two distinct oxide films were created in the surface etching process (labeled CP-A and CP-B), no qualitative changes in microroughness were seen between the two conditions. CP-A possessed significantly less Ni at the surface (0.19 at. %) than the CP-B group (3.30 at. %), via x-ray photoelectron spectroscopy, alongside a concomitant shift in the O1 s peak presentation alluding to a greater formation of a Ni based oxide in the CP-B group. Our live dead staining revealed significant toxicity and reduced cellular attachment for the CP-B group, in addition to inducing more cell lysis (20.9 ± 5.1%), which was significantly increased when compared to CP-A (P < 0.01). Future practices of manufacturing NiTi scaffolds using LPBF should focus on producing surface films that are not only smooth, but free of cytotoxic Ni based oxides.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1116/6.0003665\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1116/6.0003665","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

为了适当满足心血管应用的生物医学限制,快速成型镍钛支架需要进一步的工艺和冶金工程。用于心血管的添加制造镍钛材料必须经过表面处理,以尽量减少动脉内的负表面相互作用。在这项研究中,我们试图通过激光粉末床熔融(LPBF)了解化学蚀刻加成法制造的镍钛支架的生物相容性。虽然在表面蚀刻过程中产生了两种不同的氧化膜(CP-A 和 CP-B),但两种条件下的微观粗糙度没有质的变化。通过 X 射线光电子能谱,CP-A 组的表面镍含量(0.19%)明显低于 CP-B 组(3.30%),同时 O1 s 峰也发生了移动,这表明 CP-B 组形成了更多的镍基氧化物。我们的活死细胞染色结果表明,CP-B 组具有明显的毒性,细胞附着力降低,此外还诱导了更多的细胞裂解(20.9 ± 5.1%),与 CP-A 组相比,细胞裂解率显著增加(P.
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of metal oxides on biocompatibility of additively manufactured NiTi.

In order to properly satisfy biomedical constraints for cardiovascular applications, additively manufactured NiTi scaffolds required further process and metallurgical engineering. Additively manufactured NiTi materials for cardiovascular use will have to undergo surface finishing in order to minimize negative surface interactions within the artery. In this study, we sought to understand biocompatibility from chemically etched additively manufactured NiTi scaffolds by laser powder bed fusion (LPBF). Although two distinct oxide films were created in the surface etching process (labeled CP-A and CP-B), no qualitative changes in microroughness were seen between the two conditions. CP-A possessed significantly less Ni at the surface (0.19 at. %) than the CP-B group (3.30 at. %), via x-ray photoelectron spectroscopy, alongside a concomitant shift in the O1 s peak presentation alluding to a greater formation of a Ni based oxide in the CP-B group. Our live dead staining revealed significant toxicity and reduced cellular attachment for the CP-B group, in addition to inducing more cell lysis (20.9 ± 5.1%), which was significantly increased when compared to CP-A (P < 0.01). Future practices of manufacturing NiTi scaffolds using LPBF should focus on producing surface films that are not only smooth, but free of cytotoxic Ni based oxides.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信