{"title":"使用Edge医疗机器人平台的远程手术机器人辅助前列腺癌根治术初体验。","authors":"Marcio Covas Moschovas, Travis Rogers, Wanhai Xu, Roshane Perera, Xu Zhang, Vipul Patel","doi":"10.1590/S1677-5538.IBJU.2024.0458","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>We reported, as a referral center in prostate cancer, our perspectives and experience performing Telesurgery using robotic surgery and 5G network.</p><p><strong>Material and methods: </strong>We described and illustrated the Telesurgery applications and outcomes to treat a patient with prostate cancer located 1300 kilometers away from the surgeon (Beijing-Harbin) in China. We used the Edge Medical Robot (MP1000) in November 2023 in a 71-year-old patient with Gleason 6 (ISUP 1) in 8 cores from 13, PSA of 14 ng/dL, and clinical stage cT2a. MRI described a PIRADS 5 nodule on the left peripheral zone at the base, and 20gr prostate. We described details about the connection between centers, perioperative outcomes, and our perspectives as a referral center in prostate cancer.</p><p><strong>Results: </strong>We had no delays, or problems with network connection between the centers. The procedure was performed in 60 minutes, with no intra- or postoperative complications. Estimated blood loss was 100 mL. The patient was ambulating soon after anesthesia recovery. Final pathology described a Gleason 6 (ISUP 1) involving the left base and left seminal vesicle, negative surgical margins, and no lymph node involvement (pT3bN0). The patient was continent soon after catheter removal (7 days).</p><p><strong>Conclusion: </strong>As technological progress introduced novel robotic platforms and high-speed networks, the concept of Telesurgery became a tangible reality while 5G technology solved latency and transmission concerns. However, with these advancements, ethical considerations and regulatory frameworks should underline the importance of transparency and patient safety with responsible innovation in the field.</p>","PeriodicalId":49283,"journal":{"name":"International Braz J Urol","volume":"50 6","pages":"754-763"},"PeriodicalIF":3.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11554277/pdf/","citationCount":"0","resultStr":"{\"title\":\"First impressions of Telesurgery robotic-assisted radical prostatectomy using the Edge medical robotic platform.\",\"authors\":\"Marcio Covas Moschovas, Travis Rogers, Wanhai Xu, Roshane Perera, Xu Zhang, Vipul Patel\",\"doi\":\"10.1590/S1677-5538.IBJU.2024.0458\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>We reported, as a referral center in prostate cancer, our perspectives and experience performing Telesurgery using robotic surgery and 5G network.</p><p><strong>Material and methods: </strong>We described and illustrated the Telesurgery applications and outcomes to treat a patient with prostate cancer located 1300 kilometers away from the surgeon (Beijing-Harbin) in China. We used the Edge Medical Robot (MP1000) in November 2023 in a 71-year-old patient with Gleason 6 (ISUP 1) in 8 cores from 13, PSA of 14 ng/dL, and clinical stage cT2a. MRI described a PIRADS 5 nodule on the left peripheral zone at the base, and 20gr prostate. We described details about the connection between centers, perioperative outcomes, and our perspectives as a referral center in prostate cancer.</p><p><strong>Results: </strong>We had no delays, or problems with network connection between the centers. The procedure was performed in 60 minutes, with no intra- or postoperative complications. Estimated blood loss was 100 mL. The patient was ambulating soon after anesthesia recovery. Final pathology described a Gleason 6 (ISUP 1) involving the left base and left seminal vesicle, negative surgical margins, and no lymph node involvement (pT3bN0). The patient was continent soon after catheter removal (7 days).</p><p><strong>Conclusion: </strong>As technological progress introduced novel robotic platforms and high-speed networks, the concept of Telesurgery became a tangible reality while 5G technology solved latency and transmission concerns. However, with these advancements, ethical considerations and regulatory frameworks should underline the importance of transparency and patient safety with responsible innovation in the field.</p>\",\"PeriodicalId\":49283,\"journal\":{\"name\":\"International Braz J Urol\",\"volume\":\"50 6\",\"pages\":\"754-763\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11554277/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Braz J Urol\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1590/S1677-5538.IBJU.2024.0458\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Braz J Urol","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/S1677-5538.IBJU.2024.0458","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
First impressions of Telesurgery robotic-assisted radical prostatectomy using the Edge medical robotic platform.
Purpose: We reported, as a referral center in prostate cancer, our perspectives and experience performing Telesurgery using robotic surgery and 5G network.
Material and methods: We described and illustrated the Telesurgery applications and outcomes to treat a patient with prostate cancer located 1300 kilometers away from the surgeon (Beijing-Harbin) in China. We used the Edge Medical Robot (MP1000) in November 2023 in a 71-year-old patient with Gleason 6 (ISUP 1) in 8 cores from 13, PSA of 14 ng/dL, and clinical stage cT2a. MRI described a PIRADS 5 nodule on the left peripheral zone at the base, and 20gr prostate. We described details about the connection between centers, perioperative outcomes, and our perspectives as a referral center in prostate cancer.
Results: We had no delays, or problems with network connection between the centers. The procedure was performed in 60 minutes, with no intra- or postoperative complications. Estimated blood loss was 100 mL. The patient was ambulating soon after anesthesia recovery. Final pathology described a Gleason 6 (ISUP 1) involving the left base and left seminal vesicle, negative surgical margins, and no lymph node involvement (pT3bN0). The patient was continent soon after catheter removal (7 days).
Conclusion: As technological progress introduced novel robotic platforms and high-speed networks, the concept of Telesurgery became a tangible reality while 5G technology solved latency and transmission concerns. However, with these advancements, ethical considerations and regulatory frameworks should underline the importance of transparency and patient safety with responsible innovation in the field.