使用Edge医疗机器人平台的远程手术机器人辅助前列腺癌根治术初体验。

IF 3.1 3区 医学 Q1 UROLOGY & NEPHROLOGY
Marcio Covas Moschovas, Travis Rogers, Wanhai Xu, Roshane Perera, Xu Zhang, Vipul Patel
{"title":"使用Edge医疗机器人平台的远程手术机器人辅助前列腺癌根治术初体验。","authors":"Marcio Covas Moschovas, Travis Rogers, Wanhai Xu, Roshane Perera, Xu Zhang, Vipul Patel","doi":"10.1590/S1677-5538.IBJU.2024.0458","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>We reported, as a referral center in prostate cancer, our perspectives and experience performing Telesurgery using robotic surgery and 5G network.</p><p><strong>Material and methods: </strong>We described and illustrated the Telesurgery applications and outcomes to treat a patient with prostate cancer located 1300 kilometers away from the surgeon (Beijing-Harbin) in China. We used the Edge Medical Robot (MP1000) in November 2023 in a 71-year-old patient with Gleason 6 (ISUP 1) in 8 cores from 13, PSA of 14 ng/dL, and clinical stage cT2a. MRI described a PIRADS 5 nodule on the left peripheral zone at the base, and 20gr prostate. We described details about the connection between centers, perioperative outcomes, and our perspectives as a referral center in prostate cancer.</p><p><strong>Results: </strong>We had no delays, or problems with network connection between the centers. The procedure was performed in 60 minutes, with no intra- or postoperative complications. Estimated blood loss was 100 mL. The patient was ambulating soon after anesthesia recovery. Final pathology described a Gleason 6 (ISUP 1) involving the left base and left seminal vesicle, negative surgical margins, and no lymph node involvement (pT3bN0). The patient was continent soon after catheter removal (7 days).</p><p><strong>Conclusion: </strong>As technological progress introduced novel robotic platforms and high-speed networks, the concept of Telesurgery became a tangible reality while 5G technology solved latency and transmission concerns. However, with these advancements, ethical considerations and regulatory frameworks should underline the importance of transparency and patient safety with responsible innovation in the field.</p>","PeriodicalId":49283,"journal":{"name":"International Braz J Urol","volume":"50 6","pages":"754-763"},"PeriodicalIF":3.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11554277/pdf/","citationCount":"0","resultStr":"{\"title\":\"First impressions of Telesurgery robotic-assisted radical prostatectomy using the Edge medical robotic platform.\",\"authors\":\"Marcio Covas Moschovas, Travis Rogers, Wanhai Xu, Roshane Perera, Xu Zhang, Vipul Patel\",\"doi\":\"10.1590/S1677-5538.IBJU.2024.0458\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>We reported, as a referral center in prostate cancer, our perspectives and experience performing Telesurgery using robotic surgery and 5G network.</p><p><strong>Material and methods: </strong>We described and illustrated the Telesurgery applications and outcomes to treat a patient with prostate cancer located 1300 kilometers away from the surgeon (Beijing-Harbin) in China. We used the Edge Medical Robot (MP1000) in November 2023 in a 71-year-old patient with Gleason 6 (ISUP 1) in 8 cores from 13, PSA of 14 ng/dL, and clinical stage cT2a. MRI described a PIRADS 5 nodule on the left peripheral zone at the base, and 20gr prostate. We described details about the connection between centers, perioperative outcomes, and our perspectives as a referral center in prostate cancer.</p><p><strong>Results: </strong>We had no delays, or problems with network connection between the centers. The procedure was performed in 60 minutes, with no intra- or postoperative complications. Estimated blood loss was 100 mL. The patient was ambulating soon after anesthesia recovery. Final pathology described a Gleason 6 (ISUP 1) involving the left base and left seminal vesicle, negative surgical margins, and no lymph node involvement (pT3bN0). The patient was continent soon after catheter removal (7 days).</p><p><strong>Conclusion: </strong>As technological progress introduced novel robotic platforms and high-speed networks, the concept of Telesurgery became a tangible reality while 5G technology solved latency and transmission concerns. However, with these advancements, ethical considerations and regulatory frameworks should underline the importance of transparency and patient safety with responsible innovation in the field.</p>\",\"PeriodicalId\":49283,\"journal\":{\"name\":\"International Braz J Urol\",\"volume\":\"50 6\",\"pages\":\"754-763\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11554277/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Braz J Urol\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1590/S1677-5538.IBJU.2024.0458\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Braz J Urol","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/S1677-5538.IBJU.2024.0458","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:作为前列腺癌转诊中心,我们报告了使用机器人手术和 5G 网络进行远程手术的观点和经验:我们描述并说明了远程手术的应用和结果,治疗了一名前列腺癌患者,患者距离外科医生(北京-哈尔滨)1300 公里。我们于 2023 年 11 月使用 Edge 医疗机器人(MP1000)对一名 71 岁的患者进行了治疗,该患者的 13 个癌核中有 8 个格雷森 6(ISUP 1),PSA 为 14 ng/dL,临床分期为 cT2a。核磁共振成像显示,患者左侧外周区底部有一个 PIRADS 5 结节,前列腺大小为 20gr。我们详细介绍了各中心之间的联系、围手术期的结果以及我们作为前列腺癌转诊中心的观点:结果:各中心之间的网络连接没有出现任何延误或问题。手术在60分钟内完成,术中和术后均无并发症。估计失血量为 100 毫升。麻醉恢复后,患者很快就能下地行走。最终病理结果显示,患者的左侧基底和左侧精囊受累,Gleason 6(ISUP 1),手术切缘阴性,无淋巴结受累(pT3bN0)。患者在拔除导管后不久(7 天)就能继续行走:随着技术的进步,引入了新型机器人平台和高速网络,远程手术的概念成为了切实可行的现实,而 5G 技术则解决了延迟和传输问题。然而,在取得这些进步的同时,伦理考虑和监管框架也应强调该领域负责任创新的透明度和患者安全的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
First impressions of Telesurgery robotic-assisted radical prostatectomy using the Edge medical robotic platform.

Purpose: We reported, as a referral center in prostate cancer, our perspectives and experience performing Telesurgery using robotic surgery and 5G network.

Material and methods: We described and illustrated the Telesurgery applications and outcomes to treat a patient with prostate cancer located 1300 kilometers away from the surgeon (Beijing-Harbin) in China. We used the Edge Medical Robot (MP1000) in November 2023 in a 71-year-old patient with Gleason 6 (ISUP 1) in 8 cores from 13, PSA of 14 ng/dL, and clinical stage cT2a. MRI described a PIRADS 5 nodule on the left peripheral zone at the base, and 20gr prostate. We described details about the connection between centers, perioperative outcomes, and our perspectives as a referral center in prostate cancer.

Results: We had no delays, or problems with network connection between the centers. The procedure was performed in 60 minutes, with no intra- or postoperative complications. Estimated blood loss was 100 mL. The patient was ambulating soon after anesthesia recovery. Final pathology described a Gleason 6 (ISUP 1) involving the left base and left seminal vesicle, negative surgical margins, and no lymph node involvement (pT3bN0). The patient was continent soon after catheter removal (7 days).

Conclusion: As technological progress introduced novel robotic platforms and high-speed networks, the concept of Telesurgery became a tangible reality while 5G technology solved latency and transmission concerns. However, with these advancements, ethical considerations and regulatory frameworks should underline the importance of transparency and patient safety with responsible innovation in the field.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Braz J Urol
International Braz J Urol UROLOGY & NEPHROLOGY-
CiteScore
4.60
自引率
21.60%
发文量
246
审稿时长
6-12 weeks
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信