体外试验中,带有铸造柱和核心、预制纤维柱以及带有复合核心的聚乙烯纤维的重置颈缘长度对抗折性和边缘完整性的影响。

IF 1.9 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
International Journal of Dentistry Pub Date : 2024-08-27 eCollection Date: 2024-01-01 DOI:10.1155/2024/9274141
Naghmeh Musapoor, Hamid Neshandar Asli, Soroosh Mokhtari, Yasamin Babaee Hemmati, Mehran Falahchai
{"title":"体外试验中,带有铸造柱和核心、预制纤维柱以及带有复合核心的聚乙烯纤维的重置颈缘长度对抗折性和边缘完整性的影响。","authors":"Naghmeh Musapoor, Hamid Neshandar Asli, Soroosh Mokhtari, Yasamin Babaee Hemmati, Mehran Falahchai","doi":"10.1155/2024/9274141","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aimed to assess the effect of length of the relocated cervical margin with casting post and core (CP), prefabricated fiber post and composite core (PFP), and polyethylene fiber-reinforced composite (PEFRC) on fracture resistance and marginal integrity.</p><p><strong>Materials and methods: </strong>In this in vitro study, 70 sound human maxillary premolars were divided into seven groups according to the type of post and core system and length of the relocated cervical margin (<i>n</i> = 10): control (no preparation), PFP-3, PEFRC-3, CP-3 with 3 mm of cervical margin relocation (CMR), PFP-6, PEFRC-6, and CP-6 (with 6 mm of CMR). The samples were restored with zirconia crowns (except the control group). Epoxy resin replicas were fabricated before and after thermomechanical loading. Marginal integrity was assessed at the luting cement-core, core-tooth, and luting cement-enamel interfaces under a scanning electron microscope (SEM) (×200). Fracture resistance and failure mode were subsequently assessed. Data were analyzed by independent <i>t</i>-test, paired <i>t</i>-test, ANOVA, Tukey-Games Howell, Mann-Whitney, Kruskal-Wallis, Wilcoxon, Mann-Whitney with Bonferroni correction, and Fisher-Freeman-Halton tests (<i>α</i> = 0.05).</p><p><strong>Results: </strong>The marginal integrity of the groups with 3 mm of CMR followed the following order: PEFRC > PFP > CP at all interfaces (<i>P</i>  < 0.05). In 6-mm CMR groups, this order was CP < PFP = PEFRC at the luting cement-core and (CP < PEFRC) = PFP at the core-tooth interface. No significant difference was found in fracture resistance when comparing the 3-mm CMR groups with each other (<i>P</i>  > 0.05). PFP-6 showed higher FR than CP-6 (<i>P</i>  < 0.001). PEFRC-6 had no significant difference with PFP-6 and CP-6 (<i>P</i>  > 0.05). In each post and core system, 3-mm CMR groups showed higher marginal integrity and fracture resistance (<i>P</i>  < 0.05).</p><p><strong>Conclusion: </strong>Increasing the length of the relocated cervical margin decreased the marginal integrity and fracture resistance of all three systems of CP, PFP, and PEFRC.</p>","PeriodicalId":13947,"journal":{"name":"International Journal of Dentistry","volume":"2024 ","pages":"9274141"},"PeriodicalIF":1.9000,"publicationDate":"2024-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11371451/pdf/","citationCount":"0","resultStr":"{\"title\":\"In Vitro Effect of the Length of Relocated Cervical Margin with Casting Post and Core, Prefabricated Fiber Post, and Polyethylene Fiber with a Composite Core on Fracture Resistance and Marginal Integrity.\",\"authors\":\"Naghmeh Musapoor, Hamid Neshandar Asli, Soroosh Mokhtari, Yasamin Babaee Hemmati, Mehran Falahchai\",\"doi\":\"10.1155/2024/9274141\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>This study aimed to assess the effect of length of the relocated cervical margin with casting post and core (CP), prefabricated fiber post and composite core (PFP), and polyethylene fiber-reinforced composite (PEFRC) on fracture resistance and marginal integrity.</p><p><strong>Materials and methods: </strong>In this in vitro study, 70 sound human maxillary premolars were divided into seven groups according to the type of post and core system and length of the relocated cervical margin (<i>n</i> = 10): control (no preparation), PFP-3, PEFRC-3, CP-3 with 3 mm of cervical margin relocation (CMR), PFP-6, PEFRC-6, and CP-6 (with 6 mm of CMR). The samples were restored with zirconia crowns (except the control group). Epoxy resin replicas were fabricated before and after thermomechanical loading. Marginal integrity was assessed at the luting cement-core, core-tooth, and luting cement-enamel interfaces under a scanning electron microscope (SEM) (×200). Fracture resistance and failure mode were subsequently assessed. Data were analyzed by independent <i>t</i>-test, paired <i>t</i>-test, ANOVA, Tukey-Games Howell, Mann-Whitney, Kruskal-Wallis, Wilcoxon, Mann-Whitney with Bonferroni correction, and Fisher-Freeman-Halton tests (<i>α</i> = 0.05).</p><p><strong>Results: </strong>The marginal integrity of the groups with 3 mm of CMR followed the following order: PEFRC > PFP > CP at all interfaces (<i>P</i>  < 0.05). In 6-mm CMR groups, this order was CP < PFP = PEFRC at the luting cement-core and (CP < PEFRC) = PFP at the core-tooth interface. No significant difference was found in fracture resistance when comparing the 3-mm CMR groups with each other (<i>P</i>  > 0.05). PFP-6 showed higher FR than CP-6 (<i>P</i>  < 0.001). PEFRC-6 had no significant difference with PFP-6 and CP-6 (<i>P</i>  > 0.05). In each post and core system, 3-mm CMR groups showed higher marginal integrity and fracture resistance (<i>P</i>  < 0.05).</p><p><strong>Conclusion: </strong>Increasing the length of the relocated cervical margin decreased the marginal integrity and fracture resistance of all three systems of CP, PFP, and PEFRC.</p>\",\"PeriodicalId\":13947,\"journal\":{\"name\":\"International Journal of Dentistry\",\"volume\":\"2024 \",\"pages\":\"9274141\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-08-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11371451/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2024/9274141\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2024/9274141","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究旨在评估铸造桩核(CP)、预制纤维桩核(PFP)和聚乙烯纤维增强复合材料(PEFRC)重置颈缘的长度对抗折性和边缘完整性的影响:在这项体外研究中,70 颗健全的人类上颌前磨牙根据桩核系统的类型和颈缘重置的长度(n = 10)被分为七组:对照组(无预备)、PFP-3 组、PEFRC-3 组、CP-3 组(颈缘重置 3 mm)、PFP-6 组、PEFRC-6 组和 CP-6 组(颈缘重置 6 mm)。除对照组外,所有样本均使用氧化锆冠修复。在热机械加载前后制作环氧树脂复型。在扫描电子显微镜(SEM)(×200)下对粘结水泥-牙髓、牙髓-牙齿和粘结水泥-珐琅质界面的边缘完整性进行评估。随后评估了抗折性和破坏模式。数据分析采用独立 t 检验、配对 t 检验、方差分析、Tukey-Games Howell 检验、Mann-Whitney 检验、Kruskal-Wallis 检验、Wilcoxon 检验、Mann-Whitney 加 Bonferroni 校正检验和 Fisher-Freeman-Halton 检验(α = 0.05):有 3 毫米 CMR 的各组的边缘完整性依次为在所有界面上,PEFRC > PFP > CP(P < 0.05)。在 6 毫米 CMR 组中,这一顺序为 CP P > 0.05)。PFP-6 比 CP-6 显示出更高的 FR 值(P < 0.001)。PEFRC-6 与 PFP-6 和 CP-6 没有明显差异(P > 0.05)。在每个桩核系统中,3 毫米 CMR 组显示出更高的边缘完整性和抗折性(P < 0.05):结论:在 CP、PFP 和 PEFRC 三种系统中,增加重置颈缘的长度会降低边缘完整性和抗骨折性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
In Vitro Effect of the Length of Relocated Cervical Margin with Casting Post and Core, Prefabricated Fiber Post, and Polyethylene Fiber with a Composite Core on Fracture Resistance and Marginal Integrity.

Objective: This study aimed to assess the effect of length of the relocated cervical margin with casting post and core (CP), prefabricated fiber post and composite core (PFP), and polyethylene fiber-reinforced composite (PEFRC) on fracture resistance and marginal integrity.

Materials and methods: In this in vitro study, 70 sound human maxillary premolars were divided into seven groups according to the type of post and core system and length of the relocated cervical margin (n = 10): control (no preparation), PFP-3, PEFRC-3, CP-3 with 3 mm of cervical margin relocation (CMR), PFP-6, PEFRC-6, and CP-6 (with 6 mm of CMR). The samples were restored with zirconia crowns (except the control group). Epoxy resin replicas were fabricated before and after thermomechanical loading. Marginal integrity was assessed at the luting cement-core, core-tooth, and luting cement-enamel interfaces under a scanning electron microscope (SEM) (×200). Fracture resistance and failure mode were subsequently assessed. Data were analyzed by independent t-test, paired t-test, ANOVA, Tukey-Games Howell, Mann-Whitney, Kruskal-Wallis, Wilcoxon, Mann-Whitney with Bonferroni correction, and Fisher-Freeman-Halton tests (α = 0.05).

Results: The marginal integrity of the groups with 3 mm of CMR followed the following order: PEFRC > PFP > CP at all interfaces (P  < 0.05). In 6-mm CMR groups, this order was CP < PFP = PEFRC at the luting cement-core and (CP < PEFRC) = PFP at the core-tooth interface. No significant difference was found in fracture resistance when comparing the 3-mm CMR groups with each other (P  > 0.05). PFP-6 showed higher FR than CP-6 (P  < 0.001). PEFRC-6 had no significant difference with PFP-6 and CP-6 (P  > 0.05). In each post and core system, 3-mm CMR groups showed higher marginal integrity and fracture resistance (P  < 0.05).

Conclusion: Increasing the length of the relocated cervical margin decreased the marginal integrity and fracture resistance of all three systems of CP, PFP, and PEFRC.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Dentistry
International Journal of Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.30
自引率
4.80%
发文量
219
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信