基于多层富勒烯与介孔氮化碳的新型复合材料的制备及其在 LC-MS/MS 分析前从血浆中提取他克莫司和依维莫司的应用。

IF 2.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Rana Honarnezhad, Mohammad Reza Afshar Mogaddam, Elnaz Marzi Khosrowshahi, Mir Ali Farajzadeh and Mahboob Nemati
{"title":"基于多层富勒烯与介孔氮化碳的新型复合材料的制备及其在 LC-MS/MS 分析前从血浆中提取他克莫司和依维莫司的应用。","authors":"Rana Honarnezhad, Mohammad Reza Afshar Mogaddam, Elnaz Marzi Khosrowshahi, Mir Ali Farajzadeh and Mahboob Nemati","doi":"10.1039/D4AY01275E","DOIUrl":null,"url":null,"abstract":"<p >The development of new and efficient adsorbents for dispersive solid-phase extraction method, particularly prior to chromatography analysis, is increasing. In particular, this method is recommended for use before biological sample analysis. In this work, a new composite was prepared from mesoporous carbon nitrides and carbon nano-onions and was utilized for the extraction of tacrolimus and everolimus from plasma samples prior to high-performance liquid chromatography-tandem mass spectrometry analysis. To achieve this aim, first, mesoporous carbon nitrides and carbon nano-onions were synthesized separately and mixed at optimized proportions. Subsequently, a suitable amount of the prepared composite (5 mg) was added to 2 mL of sample solution containing the analytes under vortexing. Next, the extracted analytes were eluted using acetonitrile. The approach was linear within the ranges of 1.0–500 and 0.51–500 ng mL<small><sup>−1</sup></small> for tacrolimus and everolimus, respectively. Sensitive limits of detection (0.31 and 0.15 ng mL<small><sup>−1</sup></small> for tacrolimus and everolimus, respectively), acceptable relative standard deviations (intra- and inter-day precisions of ≤5.6% and high extraction recoveries of 71.0% and 83.0% for tacrolimus and everolimus, respectively) were obtained. The results showed that the method can be successfully applied in the simultaneous extraction of the studied analytes from plasma.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":" 37","pages":" 6411-6419"},"PeriodicalIF":2.6000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Preparation of a new composite based on multilayer fullerene with mesoporous carbon nitride and its application in the extraction of tacrolimus and everolimus from plasma prior to LC-MS/MS analysis†\",\"authors\":\"Rana Honarnezhad, Mohammad Reza Afshar Mogaddam, Elnaz Marzi Khosrowshahi, Mir Ali Farajzadeh and Mahboob Nemati\",\"doi\":\"10.1039/D4AY01275E\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >The development of new and efficient adsorbents for dispersive solid-phase extraction method, particularly prior to chromatography analysis, is increasing. In particular, this method is recommended for use before biological sample analysis. In this work, a new composite was prepared from mesoporous carbon nitrides and carbon nano-onions and was utilized for the extraction of tacrolimus and everolimus from plasma samples prior to high-performance liquid chromatography-tandem mass spectrometry analysis. To achieve this aim, first, mesoporous carbon nitrides and carbon nano-onions were synthesized separately and mixed at optimized proportions. Subsequently, a suitable amount of the prepared composite (5 mg) was added to 2 mL of sample solution containing the analytes under vortexing. Next, the extracted analytes were eluted using acetonitrile. The approach was linear within the ranges of 1.0–500 and 0.51–500 ng mL<small><sup>−1</sup></small> for tacrolimus and everolimus, respectively. Sensitive limits of detection (0.31 and 0.15 ng mL<small><sup>−1</sup></small> for tacrolimus and everolimus, respectively), acceptable relative standard deviations (intra- and inter-day precisions of ≤5.6% and high extraction recoveries of 71.0% and 83.0% for tacrolimus and everolimus, respectively) were obtained. The results showed that the method can be successfully applied in the simultaneous extraction of the studied analytes from plasma.</p>\",\"PeriodicalId\":64,\"journal\":{\"name\":\"Analytical Methods\",\"volume\":\" 37\",\"pages\":\" 6411-6419\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Methods\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2024/ay/d4ay01275e\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/ay/d4ay01275e","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

用于分散固相萃取法的新型高效吸附剂的开发日益增多,尤其是在色谱分析之前。特别是在生物样品分析前,建议使用这种方法。本研究利用介孔氮化碳和纳米碳离子制备了一种新型复合材料,用于在高效液相色谱-串联质谱分析前从血浆样品中提取他克莫司和依维莫司。为实现这一目标,首先分别合成了介孔氮化碳和纳米碳离子,并按优化比例混合。随后,将适量制备好的复合材料(5 毫克)加入 2 毫升含有分析物的样品溶液中,涡旋搅拌。然后,用乙腈洗脱提取的分析物。他克莫司和依维莫司的线性范围分别为 1.0-500 和 0.51-500 ng mL-1。该方法灵敏度高(他克莫司和依维莫司的检出限分别为 0.31 和 0.15 ng mL-1),相对标准偏差可接受(日内和日间精密度≤5.6%,他克莫司和依维莫司的提取回收率分别为 71.0% 和 83.0%)。结果表明,该方法可成功地用于从血浆中同时提取所研究的分析物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Preparation of a new composite based on multilayer fullerene with mesoporous carbon nitride and its application in the extraction of tacrolimus and everolimus from plasma prior to LC-MS/MS analysis†

Preparation of a new composite based on multilayer fullerene with mesoporous carbon nitride and its application in the extraction of tacrolimus and everolimus from plasma prior to LC-MS/MS analysis†

Preparation of a new composite based on multilayer fullerene with mesoporous carbon nitride and its application in the extraction of tacrolimus and everolimus from plasma prior to LC-MS/MS analysis†

The development of new and efficient adsorbents for dispersive solid-phase extraction method, particularly prior to chromatography analysis, is increasing. In particular, this method is recommended for use before biological sample analysis. In this work, a new composite was prepared from mesoporous carbon nitrides and carbon nano-onions and was utilized for the extraction of tacrolimus and everolimus from plasma samples prior to high-performance liquid chromatography-tandem mass spectrometry analysis. To achieve this aim, first, mesoporous carbon nitrides and carbon nano-onions were synthesized separately and mixed at optimized proportions. Subsequently, a suitable amount of the prepared composite (5 mg) was added to 2 mL of sample solution containing the analytes under vortexing. Next, the extracted analytes were eluted using acetonitrile. The approach was linear within the ranges of 1.0–500 and 0.51–500 ng mL−1 for tacrolimus and everolimus, respectively. Sensitive limits of detection (0.31 and 0.15 ng mL−1 for tacrolimus and everolimus, respectively), acceptable relative standard deviations (intra- and inter-day precisions of ≤5.6% and high extraction recoveries of 71.0% and 83.0% for tacrolimus and everolimus, respectively) were obtained. The results showed that the method can be successfully applied in the simultaneous extraction of the studied analytes from plasma.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信