{"title":"使用相位检测探头测量气泡流的不确定性","authors":"Matthias Bürgler ,&nbsp;Daniel Valero ,&nbsp;Benjamin Hohermuth ,&nbsp;Robert M. Boes ,&nbsp;David F. Vetsch","doi":"10.1016/j.ijmultiphaseflow.2024.104978","DOIUrl":null,"url":null,"abstract":"<div><p>The analysis of bubbly two-phase flows is challenging due to their turbulent nature and the need for intrusive phase-detection probes. However, accurately characterizing these flows is crucial for safely designing critical infrastructure such as dams and their appurtenant structures. The combination of dual-tip intrusive phase-detection probes with advanced signal processing algorithms enables the assessment of pseudo-instantaneous 1-D velocity time series; for which the limitations are not fully fathomed. In this investigation, we theoretically define four major sources of error, which we quantify using synthetically generated turbulent time series, coupled with the simulated response of a phase-detection probe. Based on the analysis of 10<sup>10</sup> simulated bubble trajectories, our findings show that typical high-velocity flows in hydraulic structures hold up to 15% error in the mean velocity estimations and up to 35% error in the turbulence intensity estimations for the most critical conditions, typically occurring in the proximity of the wall. Based on thousands of simulations, our study provides a novel data-driven tool for the estimation of these baseline errors (bias and uncertainties) in real-word phase-detection probe measurements of bubbly flows (air concentrations <span><math><mrow><mi>c</mi><mo>&lt;</mo><mn>40</mn><mtext>%</mtext></mrow></math></span>).</p></div>","PeriodicalId":339,"journal":{"name":"International Journal of Multiphase Flow","volume":"181 ","pages":"Article 104978"},"PeriodicalIF":3.6000,"publicationDate":"2024-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0301932224002556/pdfft?md5=23b708e3d07fc8b6d8fde01da895f02c&pid=1-s2.0-S0301932224002556-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Uncertainties in measurements of bubbly flows using phase-detection probes\",\"authors\":\"Matthias Bürgler ,&nbsp;Daniel Valero ,&nbsp;Benjamin Hohermuth ,&nbsp;Robert M. Boes ,&nbsp;David F. Vetsch\",\"doi\":\"10.1016/j.ijmultiphaseflow.2024.104978\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The analysis of bubbly two-phase flows is challenging due to their turbulent nature and the need for intrusive phase-detection probes. However, accurately characterizing these flows is crucial for safely designing critical infrastructure such as dams and their appurtenant structures. The combination of dual-tip intrusive phase-detection probes with advanced signal processing algorithms enables the assessment of pseudo-instantaneous 1-D velocity time series; for which the limitations are not fully fathomed. In this investigation, we theoretically define four major sources of error, which we quantify using synthetically generated turbulent time series, coupled with the simulated response of a phase-detection probe. Based on the analysis of 10<sup>10</sup> simulated bubble trajectories, our findings show that typical high-velocity flows in hydraulic structures hold up to 15% error in the mean velocity estimations and up to 35% error in the turbulence intensity estimations for the most critical conditions, typically occurring in the proximity of the wall. Based on thousands of simulations, our study provides a novel data-driven tool for the estimation of these baseline errors (bias and uncertainties) in real-word phase-detection probe measurements of bubbly flows (air concentrations <span><math><mrow><mi>c</mi><mo>&lt;</mo><mn>40</mn><mtext>%</mtext></mrow></math></span>).</p></div>\",\"PeriodicalId\":339,\"journal\":{\"name\":\"International Journal of Multiphase Flow\",\"volume\":\"181 \",\"pages\":\"Article 104978\"},\"PeriodicalIF\":3.6000,\"publicationDate\":\"2024-08-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0301932224002556/pdfft?md5=23b708e3d07fc8b6d8fde01da895f02c&pid=1-s2.0-S0301932224002556-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Multiphase Flow\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0301932224002556\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MECHANICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Multiphase Flow","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0301932224002556","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MECHANICS","Score":null,"Total":0}
引用次数: 0

摘要

由于气泡两相流具有湍流特性,且需要侵入式相位检测探头,因此分析气泡两相流具有挑战性。然而,准确描述这些流动的特征对于安全设计大坝及其附属结构等关键基础设施至关重要。双尖端侵入式相位检测探头与先进的信号处理算法相结合,可以评估伪瞬时一维速度时间序列,但其局限性尚不完全清楚。在这项研究中,我们从理论上定义了四个主要误差源,并利用合成生成的湍流时间序列和相位探测探头的模拟响应对其进行量化。基于对 1010 个模拟气泡轨迹的分析,我们的研究结果表明,在水力结构中的典型高速流动中,平均速度估算误差高达 15%,而在最关键的条件下(通常发生在靠近壁面的位置),湍流强度估算误差高达 35%。基于数千次模拟,我们的研究提供了一种新颖的数据驱动工具,用于估算气泡流(空气浓度为 40%)实测相位检测探头测量中的基线误差(偏差和不确定性)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Uncertainties in measurements of bubbly flows using phase-detection probes

Uncertainties in measurements of bubbly flows using phase-detection probes

The analysis of bubbly two-phase flows is challenging due to their turbulent nature and the need for intrusive phase-detection probes. However, accurately characterizing these flows is crucial for safely designing critical infrastructure such as dams and their appurtenant structures. The combination of dual-tip intrusive phase-detection probes with advanced signal processing algorithms enables the assessment of pseudo-instantaneous 1-D velocity time series; for which the limitations are not fully fathomed. In this investigation, we theoretically define four major sources of error, which we quantify using synthetically generated turbulent time series, coupled with the simulated response of a phase-detection probe. Based on the analysis of 1010 simulated bubble trajectories, our findings show that typical high-velocity flows in hydraulic structures hold up to 15% error in the mean velocity estimations and up to 35% error in the turbulence intensity estimations for the most critical conditions, typically occurring in the proximity of the wall. Based on thousands of simulations, our study provides a novel data-driven tool for the estimation of these baseline errors (bias and uncertainties) in real-word phase-detection probe measurements of bubbly flows (air concentrations c<40%).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.30
自引率
10.50%
发文量
244
审稿时长
4 months
期刊介绍: The International Journal of Multiphase Flow publishes analytical, numerical and experimental articles of lasting interest. The scope of the journal includes all aspects of mass, momentum and energy exchange phenomena among different phases such as occur in disperse flows, gas–liquid and liquid–liquid flows, flows in porous media, boiling, granular flows and others. The journal publishes full papers, brief communications and conference announcements.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信