{"title":"药物样品中局部麻醉剂普鲁卡因的电位测定。","authors":"Oguz Özbek ,&nbsp;Onur Cem Altunoluk","doi":"10.1016/j.ab.2024.115657","DOIUrl":null,"url":null,"abstract":"<div><p>In this study, a new potentiometric sensor was developed for the determination of the local anesthetic drug procaine in pharmaceutical samples. Procaine (Pr)–Tetraphenlyborate (TPB) ion–pair was synthesized and used as a sensor material. Potentiometric sensors using the synthesized ion pair (Pr–TPB), poly(vinyl chloride) (PVC) and <em>o</em>–nitrophenyloctyl ether (<em>o</em>–NPOE) in different proportions were prepared and their performance properties were tested. Among the prepared sensors, the best potentiometric response characteristics were obtained with the sensor composition Pr–TPB:PVC:<em>o</em>–NPOE in the ratio of 6.0:32.0:62.0 (w/w %). The new procaine sensor developed in the present study had a near–Nernstian behavior of 54.1 ± 3.3 mV/per decade and a low detection limit of 3.18 × 10<sup>−5</sup> mol L<sup>−1</sup> in the concentration range of 1.0 × 10<sup>−1</sup>–1.0 × 10<sup>−4</sup> mol L<sup>−1</sup>. Additionally, the sensor had a response time of less than 10 s and could work in a wide pH range for two different concentration values without being affected by pH changes. Finally, the new procaine potentiometric sensor was used to detect procaine in injection samples and successfully determined procaine concentrations with high recoveries.</p></div>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Potentiometric determination of the local anesthetic procaine in pharmaceutical samples\",\"authors\":\"Oguz Özbek ,&nbsp;Onur Cem Altunoluk\",\"doi\":\"10.1016/j.ab.2024.115657\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In this study, a new potentiometric sensor was developed for the determination of the local anesthetic drug procaine in pharmaceutical samples. Procaine (Pr)–Tetraphenlyborate (TPB) ion–pair was synthesized and used as a sensor material. Potentiometric sensors using the synthesized ion pair (Pr–TPB), poly(vinyl chloride) (PVC) and <em>o</em>–nitrophenyloctyl ether (<em>o</em>–NPOE) in different proportions were prepared and their performance properties were tested. Among the prepared sensors, the best potentiometric response characteristics were obtained with the sensor composition Pr–TPB:PVC:<em>o</em>–NPOE in the ratio of 6.0:32.0:62.0 (w/w %). The new procaine sensor developed in the present study had a near–Nernstian behavior of 54.1 ± 3.3 mV/per decade and a low detection limit of 3.18 × 10<sup>−5</sup> mol L<sup>−1</sup> in the concentration range of 1.0 × 10<sup>−1</sup>–1.0 × 10<sup>−4</sup> mol L<sup>−1</sup>. Additionally, the sensor had a response time of less than 10 s and could work in a wide pH range for two different concentration values without being affected by pH changes. Finally, the new procaine potentiometric sensor was used to detect procaine in injection samples and successfully determined procaine concentrations with high recoveries.</p></div>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S000326972400201X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"99","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S000326972400201X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

本研究开发了一种新型电位传感器,用于测定药物样品中的局麻药普鲁卡因。合成了普鲁卡因(Pr)-四苯硼酸(TPB)离子对,并将其用作传感器材料。使用合成的离子对(Pr-TPB)、聚氯乙烯(PVC)和邻硝基苯辛基醚(o-NPOE)以不同比例制备了电位传感器,并测试了其性能特性。在制备的传感器中,Pr-TPB:PVC:邻硝基苯辛基醚的比例为 6.0:32.0:62.0(重量百分比),获得了最佳的电位反应特性。在 1.0×10-1-1.0×10-4 mol L-1 的浓度范围内,本研究中开发的新型普鲁卡因传感器的响应特性接近于 Nernstian,为 54.1±3.3 mV/每年代,检测限低至 3.18×10-5 mol L-1。此外,该传感器的响应时间小于 10 秒,可在两个不同浓度值的宽 pH 值范围内工作,不受 pH 值变化的影响。最后,新的普鲁卡因电位传感器被用于检测注射样品中的普鲁卡因,并以高回收率成功测定了普鲁卡因的浓度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Potentiometric determination of the local anesthetic procaine in pharmaceutical samples

Potentiometric determination of the local anesthetic procaine in pharmaceutical samples

In this study, a new potentiometric sensor was developed for the determination of the local anesthetic drug procaine in pharmaceutical samples. Procaine (Pr)–Tetraphenlyborate (TPB) ion–pair was synthesized and used as a sensor material. Potentiometric sensors using the synthesized ion pair (Pr–TPB), poly(vinyl chloride) (PVC) and o–nitrophenyloctyl ether (o–NPOE) in different proportions were prepared and their performance properties were tested. Among the prepared sensors, the best potentiometric response characteristics were obtained with the sensor composition Pr–TPB:PVC:o–NPOE in the ratio of 6.0:32.0:62.0 (w/w %). The new procaine sensor developed in the present study had a near–Nernstian behavior of 54.1 ± 3.3 mV/per decade and a low detection limit of 3.18 × 10−5 mol L−1 in the concentration range of 1.0 × 10−1–1.0 × 10−4 mol L−1. Additionally, the sensor had a response time of less than 10 s and could work in a wide pH range for two different concentration values without being affected by pH changes. Finally, the new procaine potentiometric sensor was used to detect procaine in injection samples and successfully determined procaine concentrations with high recoveries.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信