Marco Moretti MD , Robin Vanstokstraeten PhD , Florence Crombé PhD , Kurt Barbé PhD , Ingrid Wybo MD, PhD , Sabine D. Allard MD, PhD , Joop Jonckheer MD, PhD , Deborah De Geyter PhD
{"title":"比利时四家重症监护室五年来暴发的产VIM铜绿假单胞菌疫情,调查报告(2019-2023年)。","authors":"Marco Moretti MD , Robin Vanstokstraeten PhD , Florence Crombé PhD , Kurt Barbé PhD , Ingrid Wybo MD, PhD , Sabine D. Allard MD, PhD , Joop Jonckheer MD, PhD , Deborah De Geyter PhD","doi":"10.1016/j.ajic.2024.08.022","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Verona integron-encoded metallo-β-lactamase-producing <em>Pseudomonas aeruginosa</em> (VIM-PA) outbreaks are frequently linked to contaminated sink-drains in the intensive care unit (ICU). This study aims to investigate a VIM-PA outbreak occurring at 4 ICUs in a Belgian university center.</div></div><div><h3>Methods</h3><div>Between 01/01/2019 and 30/07/2023, data were retrospectively retrieved. Whole-genome sequencing of VIM-PA was carried out for available isolates and the core genome multilocus sequencing typing (cgMLST) was used to confirm clonality. New case incidence was estimated by analyzing the weekly data of at-risk and VIM-PA-colonized patients, fitting a regression model.</div></div><div><h3>Results</h3><div>Fifty-one patients were colonized, among them, 32 (63%) were infected by VIM-PA, which contributed to 7 deaths. The outbreak investigation showed that 19 (47%) of the examined sink-drains grew at least once a VIM-PA. Two major clusters were observed by cgMLST: ST111 (59 clones with 40 clinical isolates), and ST17 (8 clones with 6 clinical isolates). The estimated incidence rate of new cases was significantly higher in one unit.</div></div><div><h3>Conclusions</h3><div>A 5-year prolonged outbreak at the UZ Brussel ICUs was caused by only 2 VIM-PA clones, both linked to sink-drains, with minimal mutations occurring throughout the years. Statistical modeling found different incidence rates between units. Tailored interventions were hence prioritized.</div></div>","PeriodicalId":7621,"journal":{"name":"American journal of infection control","volume":"52 12","pages":"Pages 1425-1431"},"PeriodicalIF":3.8000,"publicationDate":"2024-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Five-year VIM-producing Pseudomonas aeruginosa outbreak in four Belgian ICUs, an investigation report (2019-2023)\",\"authors\":\"Marco Moretti MD , Robin Vanstokstraeten PhD , Florence Crombé PhD , Kurt Barbé PhD , Ingrid Wybo MD, PhD , Sabine D. Allard MD, PhD , Joop Jonckheer MD, PhD , Deborah De Geyter PhD\",\"doi\":\"10.1016/j.ajic.2024.08.022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>Verona integron-encoded metallo-β-lactamase-producing <em>Pseudomonas aeruginosa</em> (VIM-PA) outbreaks are frequently linked to contaminated sink-drains in the intensive care unit (ICU). This study aims to investigate a VIM-PA outbreak occurring at 4 ICUs in a Belgian university center.</div></div><div><h3>Methods</h3><div>Between 01/01/2019 and 30/07/2023, data were retrospectively retrieved. Whole-genome sequencing of VIM-PA was carried out for available isolates and the core genome multilocus sequencing typing (cgMLST) was used to confirm clonality. New case incidence was estimated by analyzing the weekly data of at-risk and VIM-PA-colonized patients, fitting a regression model.</div></div><div><h3>Results</h3><div>Fifty-one patients were colonized, among them, 32 (63%) were infected by VIM-PA, which contributed to 7 deaths. The outbreak investigation showed that 19 (47%) of the examined sink-drains grew at least once a VIM-PA. Two major clusters were observed by cgMLST: ST111 (59 clones with 40 clinical isolates), and ST17 (8 clones with 6 clinical isolates). The estimated incidence rate of new cases was significantly higher in one unit.</div></div><div><h3>Conclusions</h3><div>A 5-year prolonged outbreak at the UZ Brussel ICUs was caused by only 2 VIM-PA clones, both linked to sink-drains, with minimal mutations occurring throughout the years. Statistical modeling found different incidence rates between units. Tailored interventions were hence prioritized.</div></div>\",\"PeriodicalId\":7621,\"journal\":{\"name\":\"American journal of infection control\",\"volume\":\"52 12\",\"pages\":\"Pages 1425-1431\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of infection control\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0196655324006898\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"INFECTIOUS DISEASES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of infection control","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0196655324006898","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
Five-year VIM-producing Pseudomonas aeruginosa outbreak in four Belgian ICUs, an investigation report (2019-2023)
Background
Verona integron-encoded metallo-β-lactamase-producing Pseudomonas aeruginosa (VIM-PA) outbreaks are frequently linked to contaminated sink-drains in the intensive care unit (ICU). This study aims to investigate a VIM-PA outbreak occurring at 4 ICUs in a Belgian university center.
Methods
Between 01/01/2019 and 30/07/2023, data were retrospectively retrieved. Whole-genome sequencing of VIM-PA was carried out for available isolates and the core genome multilocus sequencing typing (cgMLST) was used to confirm clonality. New case incidence was estimated by analyzing the weekly data of at-risk and VIM-PA-colonized patients, fitting a regression model.
Results
Fifty-one patients were colonized, among them, 32 (63%) were infected by VIM-PA, which contributed to 7 deaths. The outbreak investigation showed that 19 (47%) of the examined sink-drains grew at least once a VIM-PA. Two major clusters were observed by cgMLST: ST111 (59 clones with 40 clinical isolates), and ST17 (8 clones with 6 clinical isolates). The estimated incidence rate of new cases was significantly higher in one unit.
Conclusions
A 5-year prolonged outbreak at the UZ Brussel ICUs was caused by only 2 VIM-PA clones, both linked to sink-drains, with minimal mutations occurring throughout the years. Statistical modeling found different incidence rates between units. Tailored interventions were hence prioritized.
期刊介绍:
AJIC covers key topics and issues in infection control and epidemiology. Infection control professionals, including physicians, nurses, and epidemiologists, rely on AJIC for peer-reviewed articles covering clinical topics as well as original research. As the official publication of the Association for Professionals in Infection Control and Epidemiology (APIC)