利用高光谱表面等离子体共振显微镜分析组织与基底的粘附性。

IF 3.8 2区 化学 Q1 BIOCHEMICAL RESEARCH METHODS
Analytical and Bioanalytical Chemistry Pub Date : 2024-11-01 Epub Date: 2024-08-30 DOI:10.1007/s00216-024-05509-0
Bo Yang, Hongyi Tang, Ziwei Liu, Xinxia Cai, Zhi-Mei Qi
{"title":"利用高光谱表面等离子体共振显微镜分析组织与基底的粘附性。","authors":"Bo Yang, Hongyi Tang, Ziwei Liu, Xinxia Cai, Zhi-Mei Qi","doi":"10.1007/s00216-024-05509-0","DOIUrl":null,"url":null,"abstract":"<p><p>The preparation of histology slides is a critical step in histopathology, and poor-quality histology slides with weak adhesion of tissue sections to the substrate often affect diagnostic accuracy and sometimes lead to diagnostic failure due to tissue section detachment. This issue has been of concern and some methods have been proposed to enhance tissue-substrate adhesion. Unfortunately, quantitative analysis of the adhesion between tissue sections and glass slides is still challenging. In this work, the adhesion of mouse brain tissue sections on gold-coated glass slides was analyzed using a laboratory-fabricated hyperspectral surface plasmon resonance microscopy (HSPRM) system that enabled single-pixel spectral SPR sensing and provided two-dimensional (2D) distribution of resonance wavelengths (RWs). The existence of the nanoscale water gap between the tissue section and the substrate was verified by fitting the RW measured in each pixel using the five-layer Fresnel reflection model. In addition, a 2D image of the tissue-substrate adhesion distance (AD) was obtained from the measured 2D distribution of RWs. The results showed that tissue-substrate AD was 20-35 nm in deionized water and 4-24 nm in saline solution. The HSPRM system used in this work has a wide wavelength range of 400-1000 nm and can perform highly sensitive and label-free detection over a large dynamic detection range with high spectral and spatial resolutions, showing significant potential applications in stain-free tissue imaging, quantitative analysis of tissue-substrate adhesion, accurate identification of tumor cells, and rapid histopathological diagnosis.</p>","PeriodicalId":462,"journal":{"name":"Analytical and Bioanalytical Chemistry","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of tissue-substrate adhesion by hyperspectral surface plasmon resonance microscopy.\",\"authors\":\"Bo Yang, Hongyi Tang, Ziwei Liu, Xinxia Cai, Zhi-Mei Qi\",\"doi\":\"10.1007/s00216-024-05509-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The preparation of histology slides is a critical step in histopathology, and poor-quality histology slides with weak adhesion of tissue sections to the substrate often affect diagnostic accuracy and sometimes lead to diagnostic failure due to tissue section detachment. This issue has been of concern and some methods have been proposed to enhance tissue-substrate adhesion. Unfortunately, quantitative analysis of the adhesion between tissue sections and glass slides is still challenging. In this work, the adhesion of mouse brain tissue sections on gold-coated glass slides was analyzed using a laboratory-fabricated hyperspectral surface plasmon resonance microscopy (HSPRM) system that enabled single-pixel spectral SPR sensing and provided two-dimensional (2D) distribution of resonance wavelengths (RWs). The existence of the nanoscale water gap between the tissue section and the substrate was verified by fitting the RW measured in each pixel using the five-layer Fresnel reflection model. In addition, a 2D image of the tissue-substrate adhesion distance (AD) was obtained from the measured 2D distribution of RWs. The results showed that tissue-substrate AD was 20-35 nm in deionized water and 4-24 nm in saline solution. The HSPRM system used in this work has a wide wavelength range of 400-1000 nm and can perform highly sensitive and label-free detection over a large dynamic detection range with high spectral and spatial resolutions, showing significant potential applications in stain-free tissue imaging, quantitative analysis of tissue-substrate adhesion, accurate identification of tumor cells, and rapid histopathological diagnosis.</p>\",\"PeriodicalId\":462,\"journal\":{\"name\":\"Analytical and Bioanalytical Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical and Bioanalytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1007/s00216-024-05509-0\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical and Bioanalytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00216-024-05509-0","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/30 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

制备组织切片是组织病理学的关键步骤,质量差的组织切片与基底的附着力弱,往往会影响诊断的准确性,有时还会因组织切片脱落而导致诊断失败。这一问题一直备受关注,并提出了一些增强组织与基底粘附力的方法。遗憾的是,定量分析组织切片与玻璃载玻片之间的粘附力仍具有挑战性。在这项工作中,使用实验室制造的高光谱表面等离子体共振显微镜(HSPRM)系统分析了小鼠脑组织切片在镀金玻璃载玻片上的附着力,该系统可实现单像素光谱 SPR 传感,并提供共振波长(RW)的二维(2D)分布。通过使用五层菲涅尔反射模型拟合每个像素测得的共振波长,验证了组织切片与基底之间存在纳米级水隙。此外,还根据测得的 RW 的二维分布获得了组织-基底粘附距离(AD)的二维图像。结果显示,在去离子水中,组织-基底 AD 为 20-35 nm,在生理盐水中为 4-24 nm。这项工作中使用的 HSPRM 系统波长范围宽达 400-1000 nm,可在较大的动态检测范围内进行高灵敏度的无标记检测,并具有较高的光谱和空间分辨率,在无染色组织成像、组织-基底粘附定量分析、肿瘤细胞的准确识别和快速组织病理学诊断等方面显示出巨大的应用潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Analysis of tissue-substrate adhesion by hyperspectral surface plasmon resonance microscopy.

Analysis of tissue-substrate adhesion by hyperspectral surface plasmon resonance microscopy.

The preparation of histology slides is a critical step in histopathology, and poor-quality histology slides with weak adhesion of tissue sections to the substrate often affect diagnostic accuracy and sometimes lead to diagnostic failure due to tissue section detachment. This issue has been of concern and some methods have been proposed to enhance tissue-substrate adhesion. Unfortunately, quantitative analysis of the adhesion between tissue sections and glass slides is still challenging. In this work, the adhesion of mouse brain tissue sections on gold-coated glass slides was analyzed using a laboratory-fabricated hyperspectral surface plasmon resonance microscopy (HSPRM) system that enabled single-pixel spectral SPR sensing and provided two-dimensional (2D) distribution of resonance wavelengths (RWs). The existence of the nanoscale water gap between the tissue section and the substrate was verified by fitting the RW measured in each pixel using the five-layer Fresnel reflection model. In addition, a 2D image of the tissue-substrate adhesion distance (AD) was obtained from the measured 2D distribution of RWs. The results showed that tissue-substrate AD was 20-35 nm in deionized water and 4-24 nm in saline solution. The HSPRM system used in this work has a wide wavelength range of 400-1000 nm and can perform highly sensitive and label-free detection over a large dynamic detection range with high spectral and spatial resolutions, showing significant potential applications in stain-free tissue imaging, quantitative analysis of tissue-substrate adhesion, accurate identification of tumor cells, and rapid histopathological diagnosis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
8.00
自引率
4.70%
发文量
638
审稿时长
2.1 months
期刊介绍: Analytical and Bioanalytical Chemistry’s mission is the rapid publication of excellent and high-impact research articles on fundamental and applied topics of analytical and bioanalytical measurement science. Its scope is broad, and ranges from novel measurement platforms and their characterization to multidisciplinary approaches that effectively address important scientific problems. The Editors encourage submissions presenting innovative analytical research in concept, instrumentation, methods, and/or applications, including: mass spectrometry, spectroscopy, and electroanalysis; advanced separations; analytical strategies in “-omics” and imaging, bioanalysis, and sampling; miniaturized devices, medical diagnostics, sensors; analytical characterization of nano- and biomaterials; chemometrics and advanced data analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信