中耳有源植入适应症、不同方法的听力测定结果比较以及与 Vibrant Soundbridge® 的结合:单中心 20 多年的经验。

IF 2.1 Q1 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY
Joan Lorente-Piera, Raquel Manrique-Huarte, Janaina P Lima, Diego Calavia, Manuel Manrique
{"title":"中耳有源植入适应症、不同方法的听力测定结果比较以及与 Vibrant Soundbridge® 的结合:单中心 20 多年的经验。","authors":"Joan Lorente-Piera, Raquel Manrique-Huarte, Janaina P Lima, Diego Calavia, Manuel Manrique","doi":"10.3390/audiolres14040061","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Middle ear active implants, such as the Vibrant Soundbridge (VSB), offer an alternative to reconstructive surgery and other implantable hearing aid systems for patients with conductive, mixed, or sensorineural hearing loss. The primary objective of this work is to describe the auditory results obtained with VSB in our patient cohort, measuring the auditory gain in terms of average tonal thresholds and spoken word discrimination at 65 dB. Secondly, auditory gain differences between different types of hearing loss, coupling to the ossicular chain compared to round and oval windows, and the impact of open versus more conservative surgical approaches, were analyzed.</p><p><strong>Methods: </strong>A cross-sectional observational study, with retrospective data collection, was conducted at a tertiary care center. Clinical and audiometric data pre- and post-implantation were included, from patients who underwent VSB device placement surgery between 2001 and 2024.</p><p><strong>Results: </strong>55 patients with an average age of 62.58 ± 17.83 years and a slight preference in terms of the female gender (52.72%) were included in the study. The average gain in the PTA for all types of hearing loss was 41.56 ± 22.63 dB, while for sensorineural hearing loss (SNHL) the gain was 31.04 ± 8.80 dB. For mixed-conductive hearing loss (C-MHL) a gain of 42.96 ± 17.70 was achieved, notably, in terms of absolute values, at frequencies of 4000 and 6000 Hz, with gains reaching 49.25 ± 20.26 dB at 4 K and 51.16 ± 17.48 dB at 6 K. In terms of spoken word discrimination, for all types of hearing loss, an improvement of 75.20 ± 10.11% was achieved. However, patients with C-MHL exhibited an approximately 13% higher gain compared to those with SNHL (69.32 ± 24.58% vs. 57.79 ± 15.28%). No significant differences in auditory gain were found between open and closed surgical techniques, nor in the proportion of adverse effects, when comparing one technique with the other.</p><p><strong>Conclusions: </strong>The VSB is effective in improving hearing in patients with mixed, conductive, and sensorineural hearing loss, with significant gains at high frequencies, especially through the round window membrane approach. The choice of surgical technique should consider the patient's anatomical characteristics and specific needs in order to optimize auditory outcomes and minimize postoperative complications.</p>","PeriodicalId":44133,"journal":{"name":"Audiology Research","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11351701/pdf/","citationCount":"0","resultStr":"{\"title\":\"Middle Ear Active Implant Indications, Comparative Audiometric Results from Different Approaches, and Coupling with the Vibrant Soundbridge<sup>®</sup>: A Single Center Experience over More Than 20 Years.\",\"authors\":\"Joan Lorente-Piera, Raquel Manrique-Huarte, Janaina P Lima, Diego Calavia, Manuel Manrique\",\"doi\":\"10.3390/audiolres14040061\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Middle ear active implants, such as the Vibrant Soundbridge (VSB), offer an alternative to reconstructive surgery and other implantable hearing aid systems for patients with conductive, mixed, or sensorineural hearing loss. The primary objective of this work is to describe the auditory results obtained with VSB in our patient cohort, measuring the auditory gain in terms of average tonal thresholds and spoken word discrimination at 65 dB. Secondly, auditory gain differences between different types of hearing loss, coupling to the ossicular chain compared to round and oval windows, and the impact of open versus more conservative surgical approaches, were analyzed.</p><p><strong>Methods: </strong>A cross-sectional observational study, with retrospective data collection, was conducted at a tertiary care center. Clinical and audiometric data pre- and post-implantation were included, from patients who underwent VSB device placement surgery between 2001 and 2024.</p><p><strong>Results: </strong>55 patients with an average age of 62.58 ± 17.83 years and a slight preference in terms of the female gender (52.72%) were included in the study. The average gain in the PTA for all types of hearing loss was 41.56 ± 22.63 dB, while for sensorineural hearing loss (SNHL) the gain was 31.04 ± 8.80 dB. For mixed-conductive hearing loss (C-MHL) a gain of 42.96 ± 17.70 was achieved, notably, in terms of absolute values, at frequencies of 4000 and 6000 Hz, with gains reaching 49.25 ± 20.26 dB at 4 K and 51.16 ± 17.48 dB at 6 K. In terms of spoken word discrimination, for all types of hearing loss, an improvement of 75.20 ± 10.11% was achieved. However, patients with C-MHL exhibited an approximately 13% higher gain compared to those with SNHL (69.32 ± 24.58% vs. 57.79 ± 15.28%). No significant differences in auditory gain were found between open and closed surgical techniques, nor in the proportion of adverse effects, when comparing one technique with the other.</p><p><strong>Conclusions: </strong>The VSB is effective in improving hearing in patients with mixed, conductive, and sensorineural hearing loss, with significant gains at high frequencies, especially through the round window membrane approach. The choice of surgical technique should consider the patient's anatomical characteristics and specific needs in order to optimize auditory outcomes and minimize postoperative complications.</p>\",\"PeriodicalId\":44133,\"journal\":{\"name\":\"Audiology Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-08-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11351701/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Audiology Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/audiolres14040061\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiology Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/audiolres14040061","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:中耳有源植入体,如 Vibrant Soundbridge(VSB),为传导性、混合性或感音神经性听力损失患者提供了重建手术和其他植入式助听器系统的替代方案。这项工作的主要目的是描述在我们的患者群中使用 VSB 所获得的听觉效果,以 65 分贝的平均音调阈值和口语分辨力来测量听觉增益。其次,分析不同类型听力损失之间的听觉增益差异、与听骨链的耦合、与圆窗和椭圆窗的耦合,以及开放手术方法与保守手术方法的影响:方法:在一家三级医疗中心进行了一项横断面观察研究,并收集了回顾性数据。结果:55 名患者,平均年龄为 62 岁:研究共纳入 55 名患者,平均年龄(62.58 ± 17.83)岁,其中女性略占多数(52.72%)。所有类型听力损失的 PTA 平均增益为(41.56 ± 22.63)分贝,感音神经性听力损失(SNHL)的增益为(31.04 ± 8.80)分贝。混合传导性听力损失(C-MHL)的增益为 42.96 ± 17.70,特别是在 4000 和 6000 Hz 频率下的绝对值,在 4 K 和 6 K 下的增益分别达到 49.25 ± 20.26 dB 和 51.16 ± 17.48 dB。然而,C-MHL 患者的听觉增益比 SNHL 患者高出约 13%(69.32 ± 24.58% vs. 57.79 ± 15.28%)。开放式和封闭式手术技术在听觉增益方面没有发现明显差异,在不良反应比例方面也没有发现明显差异:VSB能有效改善混合性听力损失、传导性听力损失和感音神经性听力损失患者的听力,尤其是通过圆窗膜法,高频听力增益明显。选择手术技术时应考虑患者的解剖特点和具体需求,以优化听力效果并减少术后并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Middle Ear Active Implant Indications, Comparative Audiometric Results from Different Approaches, and Coupling with the Vibrant Soundbridge®: A Single Center Experience over More Than 20 Years.

Background: Middle ear active implants, such as the Vibrant Soundbridge (VSB), offer an alternative to reconstructive surgery and other implantable hearing aid systems for patients with conductive, mixed, or sensorineural hearing loss. The primary objective of this work is to describe the auditory results obtained with VSB in our patient cohort, measuring the auditory gain in terms of average tonal thresholds and spoken word discrimination at 65 dB. Secondly, auditory gain differences between different types of hearing loss, coupling to the ossicular chain compared to round and oval windows, and the impact of open versus more conservative surgical approaches, were analyzed.

Methods: A cross-sectional observational study, with retrospective data collection, was conducted at a tertiary care center. Clinical and audiometric data pre- and post-implantation were included, from patients who underwent VSB device placement surgery between 2001 and 2024.

Results: 55 patients with an average age of 62.58 ± 17.83 years and a slight preference in terms of the female gender (52.72%) were included in the study. The average gain in the PTA for all types of hearing loss was 41.56 ± 22.63 dB, while for sensorineural hearing loss (SNHL) the gain was 31.04 ± 8.80 dB. For mixed-conductive hearing loss (C-MHL) a gain of 42.96 ± 17.70 was achieved, notably, in terms of absolute values, at frequencies of 4000 and 6000 Hz, with gains reaching 49.25 ± 20.26 dB at 4 K and 51.16 ± 17.48 dB at 6 K. In terms of spoken word discrimination, for all types of hearing loss, an improvement of 75.20 ± 10.11% was achieved. However, patients with C-MHL exhibited an approximately 13% higher gain compared to those with SNHL (69.32 ± 24.58% vs. 57.79 ± 15.28%). No significant differences in auditory gain were found between open and closed surgical techniques, nor in the proportion of adverse effects, when comparing one technique with the other.

Conclusions: The VSB is effective in improving hearing in patients with mixed, conductive, and sensorineural hearing loss, with significant gains at high frequencies, especially through the round window membrane approach. The choice of surgical technique should consider the patient's anatomical characteristics and specific needs in order to optimize auditory outcomes and minimize postoperative complications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Audiology Research
Audiology Research AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY-
CiteScore
2.30
自引率
23.50%
发文量
56
审稿时长
11 weeks
期刊介绍: The mission of Audiology Research is to publish contemporary, ethical, clinically relevant scientific researches related to the basic science and clinical aspects of the auditory and vestibular system and diseases of the ear that can be used by clinicians, scientists and specialists to improve understanding and treatment of patients with audiological and neurotological disorders.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信